CHAPTER FOUR
GENERAL MINE SAFETY RULES FOR UNDERGROUND COAL MINES
Subpart A--General
S 75.1 Scope.
This Part 75 sets forth safety standards compliance with which is mandatory in each underground coal mine subject to the Federal Mine Safety and Health Act of 1977. Some standards also are applicable to surface operations. Regulations and criteria supplementary to these standards also are set forth in this part.
S 75.2 Definitions.
The following definitions apply in this part.
Act. The Federal Mine Safety and Health Act of 1977.
Active workings. Any place in a coal mine where miners are normally required to work or travel.
Anthracite. Coals with a volatile ratio equal to 0.12 or less. The volatile ratio is the volatile matter content divided by the volatile matter plus the fixed carbon.
Certified or registered. As applied to any person, a person certified or registered by the State in which the coal mine is located to perform duties prescribed by this part 75, except that in a State where no program of certification or registration is provided or where the program does not meet at least minimum Federal standards established by the Secretary, such certification or registration shall be by the Secretary.
Coal mine. Includes areas of adjoining mines connected underground.
Low voltage. Up to and including 660 volts, medium voltage means voltages from 661 to 1,000 volts; and high voltage means more than 1,000 volts.
Permissible. (1) As applied to electric face equipment, all electrically operated equipment taken into or used inby the last open crosscut of an entry or a room of any coal mine the electrical parts of which, including, but not limited to, associated electrical equipment, components, and accessories, are designed, constructed, and installed, in accordance with the specifications of the Secretary, to assure that such equipment will not cause a mine explosion or mine fire, and the other features of which are de- signed and constructed, in accordance with the specifications of the Secretary, to prevent, to the greatest extent possible, other accidents in the use of such equipment. The regulations of the Secretary or the Director of the Bureau of Mines in effect on March 30, 1970, relating to the requirements for investiga- tion, testing, approval, certification, and acceptance of such equipment as permissible shall continue in effect until modified or superseded by the Secretary, except that the Secretary shall provide procedures, including, where feasible, testing, approval, certification, and acceptance in the field by an authorized representative of the Secretary, to facilitate compliance by an operator with the requirements of S 75.500 within the periods prescribed in S 75.500.
(2) As applied to equipment other than permissible electric face equipment: (i) Equipment used in the operation of a coal mine to which an approval plate, label, or other device is attached as autho- rized by the Secretary and which meets specifications which are prescribed by the Secretary for the construction and maintenance of such equipment and are designed to assure that such equipment will not cause a mine explosion or a mine fire. (ii) The manner of use of equipment means the manner of use prescribed by the Secretary.
Qualified person. As the context requires:
(1) An individual deemed qualified by the Secretary and designated by the operator to make tests and examinations required by this part 75; and
(2) An individual deemed, in accordance with minimum requirements to be established by the Secretary, qualified by training, education, and experience, to perform electrical work, to maintain electrical equipment, and to conduct examinations and tests of all electrical equipment.
Respirable dust. Dust collected with a sampling device approved by the Secretary and the Secre- tary of Health and Human Services in accordance with part 74--Coal Mine Dust Personal Sampler Units of this title. Sampling device approvals issued by the Secretary of the Interior and Secretary of Health, Education, and Welfare are continued in effect.
Rock dust. Pulverized limestone, dolomite, gypsum, anhydrite, shale, adobe, or other inert material, preferably light colored, 100 percent of which will pass through a sieve having 20 meshes per linear inch and 70 percent or more of which will pass through a sieve having 200 meshes per linear inch; the particles of which when wetted and dried will not cohere to form a cake which will not be dispersed into separate particles by a light blast of air; and which does not contain more than 5 percent combus- tible matter or more than a total of 4 percent free and combined silica (SiO2), or, where the Secretary finds that such silica concentrations are not available, which does not contain more than 5 percent of free and combined silica.
Secretary. The Secretary of Labor or the Secretary's delegate.
State Mine Inspector means the State Mine Inspector of the State of Wyoming and any Deputy State Mine Inspectors employed by the Inspector.
Working face. Any place in a coal mine in which work of extracting coal from its natural deposit in the earth is performed during the mining cycle.
Working place. The area of a coal mine inby the last open crosscut.
Working section. All areas of the coal mine from the loading point of the section to and including the working faces.
Subpart B-Qualified and Certified Persons 75.100 Certified person.
(a) The provisions of Subpart D-Ventilation of this Part 75 require that certain examinations and tests be made by a certified person. A certified person within the meaning of those provisions is a person who has been certified as a mine foreman (mine manager), an assistant mine foreman (section foreman), or a preshift examiner (mine examiner). A person who has been so certified is also a qualified person within the meaning of those provisions of Subpart D of this part which require that certain tests be made by a qualified person and within the meaning of S 75.1106.
(b) A person who is certified as a mine foreman, an assistant mine foreman, or a preshift exam- iner by the State in which the coal mine is located is, to the extent of the State's certification, a certified person within the meaning of the provisions of Subpart D of this part and S 75.1106 referred to in para- graph (a) of this section.
(c)(1) The Secretary may certify persons in the categories of mine foreman, assistant mine fore- man, and preshift examiner whenever the State in which persons are presently employed in these catego- ries does not provide for such certification. A person's initial certification by MSHA is valid for as long as the person continues to satisfy the requirements necessary to obtain the certification and is employed at the same coal mine or by the same independent contractor. The mine operator or independent contrac- tor shall make an application which satisfactorily shows that each such person has had at least 2 years underground experience in a coal mine, and has held the position of mine foreman, assistant mine foreman, or preshift examiner for a period of 6 months immediately preceding the filing of the applica- tion, and is qualified to test for methane and for oxygen deficiency. Applications for Secretarial certifica- tion should be submitted in writing to the Health and Safety Activity, Mine Safety and Health Adminis- tration, Certification and Qualification Center, P.O. Box 25367, Denver Federal Center, Denver, Colo- rado 80225.
(2) A person certified by the Secretary under this paragraph will be a certified person, within the meaning of the provisions for Subpart D of this part and S 75.1106 referred to in paragraph (a) of this section, as long as that person continues to satisfy the requirements for qualification or certification and is employed at the same coal mine or by the same independent contractor.
S 75.150 Tests for methane and for oxygen deficiency; qualified person.
(a) The provisions of Subpart D-Ventilation of this part and S 75.1106 require that tests for methane and for oxygen deficiency be made by a qualified person. A person is a qualified person for this purpose if he is a certified person under S 75.100.
(b) Pending issuance of Federal standards, a person will be considered a qualified person for testing for methane and for oxygen deficiency:
(1) If he has been qualified for this purpose by the State in which the coal mine is located; or
(2) The Secretary may qualify persons for this purpose in a coal mine in which persons are not qualified for this purpose by the State upon an application and a satisfactory showing by the operator of the coal mine that each such person has been trained and designated by the operator to test for methane and oxygen deficiency and has made such tests for a period of 6 months immediately preceding the application. Applications for Secretarial qualification should be submitted to the Health and Safety Activity, Mine Safety and Health Administration, Certification and Qualification Center, P.O. Box 25367, Denver Federal Center, Denver, Colo. 80225.
S 75.151 Tests for methane; qualified person; additional requirement.
Notwithstanding the provisions of S 75.150, on and after January 1, 1971, no person shall be a qualified person for testing for methane unless he demonstrates to the satisfaction of an authorized representative of the Secretary that he is qualified to test for methane with a portable methane detector approved by the Bureau of Mines or the Mine Safety and Health Administration under Part 22 of this chapter (Bureau of Mines Schedule 8C).
S 75.152 Tests of air flow; qualified person.
A person is a qualified person within the meaning of the provisions of Subpart D-Ventilation of this part requiring that tests of air flow be made by a qualified person only if he is a certified person under S 75.100 or a person trained and designated by a certified person to perform such tests.
S 75.153 Electrical work; qualified person.
(a) Except as provided in paragraph (f) of this section, an individual is a qualified person within the meaning of SS 75.511 and 75.512 to perform electrical work (other than work on energized surface high-voltage lines) if--
(1) He has been qualified as a coal mine electrician by a State that has a coal mine electrical qualification program approved by the Secretary; or,
(2) He has at least 1 year of experience in performing electrical work underground in a coal mine, in the surface work areas of an underground coal mine, in a surface coal mine, in a noncoal mine, in the mine equipment manufacturing industry, or in any other industry using or manufacturing similar equipment, and has satisfactorily completed a coal mine electrical training program approved by the Secretary; or,
(3) He has at least 1 year of experience, prior to the date of the application required by paragraph
(c) of this section, in performing electrical work underground in a coal mine, in the surface work areas of an underground coal mine, in a surface coal mine, in a noncoal mine, in the mine equipment manufactur- ing industry, or in any other industry using or manufacturing similar equipment, and he attains a satisfac- tory grade on each of the series of five written tests approved by the Secretary and prescribed in para- graph (b) of this section.
(b) The series of five written tests approved by the Secretary shall include the following catego- ries:
(1) Direct current theory and application;
(2) Alternating current theory and application;
(3) Electric equipment and circuits;
(4) Permissibility of electric equipment; and,
(5) Requirements of subparts F through K of this part 75.
(c) In order to take the series of five written tests approved by the Secretary, an individual shall apply to the District Manager and shall certify that he meets the requirements of paragraph (a)(3) of this section. The tests will be administered in the Coal Mine Safety and Health Districts at regular intervals, or as demand requires.
(d) A score of at least 80 percent of each of the five written tests will be deemed to be a satisfac- tory grade. Recognition shall be given to practical experience in that 1 percentage point shall be added to an individual's score in each test for each additional year of experience beyond the 1 year minimum requirement specified in paragraph (a)(3) of this section; however, in no case shall an individual be given more than 5 percentage points for such practical experience.
(e) An individual may, within 30 days from the date on which he received notification from the Administration of his test scores, repeat those on which he received an unsatisfactory score. If further retesting is necessary after this initial repetition, a minimum of 30 days from the date of receipt of notification of the initial retest scores shall elapse prior to such further retesting.
(f) An individual who has, prior to November 1, 1972, been qualified to perform electrical work specified in SS 75.511 and 75.512 (other than work on energized surface high-voltage lines) shall con- tinue to be qualified until June 30, 1973. To remain qualified after June 30, 1973, such individual shall meet the requirements of either paragraph (a)(1), (2), or (3) of this section.
(g) An individual qualified in accordance with this section shall, in order to retain qualification, certify annually to the District Manager, that he has satisfactorily completed a coal mine electrical retraining program approved by the Secretary.
S 75.154 Repair of energized surface high voltage lines; qualified person.
An individual is a qualified person within the meaning of S 75.705 for the purpose of repairing energized surface high voltage lines only if he has had at least 2 years experience in electrical mainte- nance, and at least 2 years experience in the repair of energized high voltage surface lines located on poles or structures.
S 75.155 Qualified hoisting engineer; qualifications.
(a)(1) A person is a qualified hoisting engineer within the provisions of subpart O of this part, for the purpose of operating a steam-driven hoist in a coal mine, if he has at least 1 year experience as an engineer in a steam-driven hoisting plant and is qualified by the State in which the mine is located as a steam-hoisting engineer; or
(2) If a State has no program for qualifying persons as steam-hoisting engineers, the Secretary may qualify persons for this purpose if the operator of the coal mine in which such persons are em- ployed, or the independent contractor, makes an application and a satisfactory showing that each such person has had 1 year experience in operating steam-driven hoists and has held the position of hoisting engineer for a period of 6 months immediately preceding the application. A person's qualification is valid for as long as this person continues to satisfy the requirements necessary for qualification and is employed at the same coal mine or by the same independent contractor.
(b)(1) A person is a qualified hoisting engineer within the provisions of subpart O of this part, for the purpose of operating an electrically driven hoist in a coal mine, if he has at least 1 year experience operating a hoist plant in a mine or maintaining electric-hoist equipment in a mine and is qualified by the State in which the mine is located as an electric-hoisting engineer; or
(2) If a State has no program for qualifying persons as electric-hoisting engineers, the Secretary may qualify persons for this purpose if the operator of the coal mine in which such persons are em- ployed, or the independent contractor, makes an application and a satisfactory showing that each such person has had 1 year experience in operating electric-driven hoists and has held the position of hoisting engineer for a period of 6 months immediately preceding the application. A person's qualification is valid for as long as this person continues to satisfy the requirements for qualification and is employed at the same coal mine or by the same independent contractor.
(c) Applications for Secretarial qualification should be submitted to the Health and Safety Activ- ity, Mine Safety and Health Administration, Certification and Qualification Center, P.O. Box 25367, Denver Federal Center, Denver, Colo. 80225.
S 75.159 Records of certified and qualified persons.
The operator of each coal mine shall maintain a list of all certified and qualified persons desig- nated to perform duties under this part 75.
S 75.160 Training programs.
[Statutory Provision]
Every operator of a coal mine shall provide a program, approved by the Secretary, of training and retraining of both qualified and certified persons needed to carry out functions prescribed in the Act.
S 75.161 Plans for training programs.
Each mine operator shall submit to the District Manager a program or plan setting forth what, when, how, and where the operator will train and retrain persons whose work assignments require that they be qualified or certified. The program shall provide--
(a) For certified persons, annual training courses in methane measurement and oxygen deficiency testing, roof and rib control, ventilation, first aid, principles of mine rescue, and the provisions of this part 75;
(b) For qualified persons, annual courses in performance of the tasks which they perform as qualified persons; and
(c) For certified persons, annual training in the use of self-contained self-rescue devices used at the mine. This training shall include complete donning procedures in which each person assumes proper position, opens the device, activates the device, inserts the mouthpiece or simulates this task while explaining proper insertion of the mouthpiece, and puts on the nose clip.
Subpart C--Roof Support
S 75.200 Scope.
This subpart C sets forth requirements for controlling roof, face and ribs, including coal or rock bursts, in underground coal mines. Roof control systems installed prior to the effective date of this subpart are not affected so long as the support system continues to effectively control the roof, face and ribs.
S 75.201 Definitions.
Automated temporary roof support (ATRS) system. A device to provide temporary roof support from a location where the equipment operator is protected from roof falls.
Pillar recovery. Any reduction in pillar size during retreat mining.
S 75.202 Protection from falls of roof, face and ribs.
(a) The roof, face and ribs of areas where persons work or travel shall be supported or otherwise controlled to protect persons from hazards related to falls of the roof, face or ribs and coal or rock bursts.
(b) No person shall work or travel under unsupported roof unless in accordance with this subpart.
S 75.203 Mining methods.
(a) The method of mining shall not expose any person to hazards caused by excessive widths of rooms, crosscuts and entries, or faulty pillar recovery methods. Pillar dimensions shall be compatible with effective control of the roof, face and ribs and coal or rock bursts.
(b) A sightline or other method of directional control shall be used to maintain the projected direction of mining in entries, rooms, crosscuts and pillar splits.
(c) A sidecut shall be started only from an area that is supported in accordance with the roof control plan.
(d) A working face shall not be mined through into an unsupported area of active workings, except when the unsupported area is inaccessible.
(e) Additional roof support shall be installed where-
(1) The width of the opening specified in the roof control plan is exceeded by more than 12 inches; and
(2) The distance over which the excessive width exists is more than 5 feet.
S 75.204 Roof bolting.
(a) For roof bolts and accessories addressed in ASTM F432-88, "Standard Specification for Roof and Rock Bolts and Accessories", the mine operator shall-
(1) Obtain a manufacturer's certification that the material was manufactured and tested in accor- dance with the specifications of ASTM F432-88; and
(2) Make this certification available to an authorized representative of the Secretary and the State Mine Inspector.
(b) Roof bolts and accessories not addressed in ASTM F432-88 may be used, provided that the use of such materials is approved by the District Manager based on--
(1) Demonstrations which show that the materials have successfully supported the roof in an area of a coal mine with similar strata, opening dimensions and roof stresses; or
(2) Tests which show the materials to be effective for supporting the roof in an area of the af- fected mine which has similar strata, opening dimensions and roof stresses as the area where the roof bolts are to be used. During the test process, access to the test area shall be limited to persons necessary to conduct the test.
(c)(1) A bearing plate shall be firmly installed with each roof bolt.
(2) Bearing plates used directly against the mine roof shall be at least 6 inches square or the equivalent, except that where the mine roof is firm and not susceptible to sloughing, bearing plates 5 inches square or the equivalent may be used.
(3) Bearing plates used with wood or metal materials shall be at least 4 inches square or the equivalent.
(4) Wooden materials that are used between a bearing plate and the mine roof in areas which will exist for three years or more shall be treated to minimize deterioration.
(d) When washers are used with roof bolts, the washers shall conform to the shape of the roof bolt head and bearing plate.
(e)(1) The diameter of finishing bits shall be within a tolerance of plus or minus 0.030 inch of the manufacturer's recommended hole diameter for the anchor used.
(2) When separate finishing bits are used, they shall be distinguishable from other bits.
(f) Tensioned roof bolts. (1) Roof bolts that provide support by creating a beam of laminated strata shall be at least 30 inches long. Roof bolts that provide support by suspending the roof from overlying stronger strata shall be long enough to anchor at least 12 inches into the stronger strata.
(2) Test holes, spaced at intervals specified in the roof control plan, shall be drilled to a depth of at least 12 inches above the anchorage horizon of mechanically anchored tensioned bolts being used. When a test hole indicates that bolts would not anchor in competent strata, corrective action shall be taken.
( The installed torque or tension ranges for roof bolts as specified in the roof control plan shall maintain the integrity of the support system and shall not exceed the yield point of the roof bolt nor anchorage capacity of the strata.
(4) In each roof bolting cycle, the actual torque or tension of the first tensioned roof bolt installed with each drill head shall be measured immediately after it is installed. Thereafter, for each drill head used, at least one roof bolt out of every four installed shall be measured for actual torque or tension. If the torque or tension of any of the roof bolts measured is not within the range specified in the roof control plan, corrective action shall be taken.
(5) In working places from which coal is produced during any portion of a 24-hour period, the actual torque or tension on at least one out of every ten previously installed mechanically anchored tensioned roof bolts shall be measured from the outby corner of the last open crosscut to the face in each advancing section. Corrective action shall be taken if the majority of the bolts measured-
(i) Do not maintain at least 70 percent of the minimum torque or tension specified in the roof control plan, 50 percent if the roof bolt plates bear against wood; or
(ii) Have exceeded the maximum specified torque or tension by 50 percent.
(6) The mine operator or a person designated by the operator shall certify by signature and date that measurements required by paragraph (f)(5) of this section have been made. This certification shall be maintained for at least one year and shall be made available to an authorized representative of the Secretary, the State Mine Inspector and representatives of the miners.
(7) Tensioned roof bolts installed in the roof support pattern shall not be used to anchor trailing cables or used for any other purpose that could affect the tension of the bolt. Hanging trailing cables, line brattice, telephone lines, or other similar devices which do not place sudden loads on the bolts are permitted.
(8) Angle compensating devices shall be used to compensate for the angle when tensioned roof bolts are installed at angles greater than 5 degrees from the perpendicular to the bearing plate.
(g) Non-tensioned grouted roof bolts. The first non-tensioned grouted roof bolt installed during each roof bolting cycle shall be tested during or immediately after the first row of bolts has been in- stalled. If the bolt tested does not withstand at least 150 foot-pounds of torque without rotating in the hole, corrective action shall be taken.
S 75.205 Installation of roof support using mining machines with integral roof bolters.
When roof bolts are installed by a continuous mining machine with integral roof bolting equip- ment--
(a) The distance between roof bolts shall not exceed 10 feet crosswise.
(b) Roof bolts to be installed 9 feet or more apart shall be installed with a wooden crossbar at least 3 inches thick and 8 inches wide, or material which provides equivalent support.
(c) Roof bolts to be installed more than 8 feet but less than 9 feet apart shall be installed with a wooden plank at least 2 inches thick and 8 inches wide, or material which provides equivalent support.
S 75.206 Conventional roof support.
(a) Except in anthracite mines using non-mechanized mining systems, when conventional roof support materials are used as the only means of support--
(1) The width of any opening shall not exceed 20 feet;
(2) The spacing of roadway roof support shall not exceed 5 feet;
(3)(i) Supports shall be installed to within 5 feet of the uncut face;
(ii) When supports nearest the face must be removed to facilitate the operation of face equip- ment, equivalent temporary support shall be installed prior to removing the supports;
(4) Straight roadways shall not exceed 16 feet wide where full overhead support is used and 14 feet wide where only posts are used;
(5) Curved roadways shall not exceed 16 feet wide; and
(6) The roof at the entrance of all openings along travelways which are no longer needed for storing supplies or for travel of equipment shall be supported by extending the line of support across the opening.
(b) Conventional roof support materials shall meet the following specifications:
(1) The minimum diameter of cross-sectional area of wooden posts shall be as follows:
|
Post length
(in inches)
|
Diameter of round
posts (in inches
|
Cross-sectional area
of split posts (in
square inches)
|
| 60 or less | 4 | 13 |
| Over 60 to 84 | 5 | 20 |
| Over 84 to 108 | 6 | 28 |
| Over 108 to 132 | 7 | 39 |
| Over 132 to 156 | 8 | 50 |
| Over 156 to 180 | 9 | 64 |
| Over 180 to 204 | 10 | 79 |
| Over 204 to 228 | 11 | 95 |
| Over 228 | 12 | 113 |
(2) Wooden materials used for support shall have the following dimensions:
(i) Cap blocks and footings shall have flat sides and be at least 2 inches thick, 4 inches wide and 12 inches long.
(ii) Crossbars shall have a minimum cross-sectional area of 24 square inches and be at least 3 inches thick.
(iii) Planks shall be at least 6 inches wide and 1 inch thick.
(3) Cribbing materials shall have at least two parallel flat sides.
(c) A cluster of two or more posts that provide equivalent strength may be used to meet the requirements of paragraph (b)(1) of this section, except that no post shall have a diameter less than 4 inches or have a cross-sectional area less than 13 square inches.
(d) Materials other than wood used for support shall have support strength at least equivalent to wooden material meeting the applicable provisions of this section.
(e) Posts and jacks shall be tightly installed on solid footing.
(f) When posts are installed under roof susceptible to sloughing a cap block, plank, crossbar or materials that are equally effective shall be placed between the post and the roof.
(g) Blocks used for lagging between the roof and crossbars shall be spaced to distribute the load.
(h) Jacks used for roof support shall be used with at least 36 square inches of roof bearing sur- face.
S 75.207 Pillar recovery.
Pillar recovery shall be conducted in the following manner, unless otherwise specified in the roof control plan:
(a) Full and partial pillar recovery shall not be conducted on the same pillar line, except where physical conditions such as unstable floor or roof, falls of roof, oil and gas well barriers or surface subsidence require that pillars be left in place.
(b) Before mining is started in a pillar split or lift-
(1) At least two rows of breaker posts or equivalent support shall be installed--
(i) As close to the initial intended breakline as practicable; and
(ii) Across each opening leading into an area where full or partial pillar extraction has been completed.
(2) A row of roadside-radius (turn) posts or equivalent support shall be installed leading into the split or lift.
(c) Before mining is started on a final stump--
(1) At least 2 rows of posts or equivalent support shall be installed on not more than 4-foot centers on each side of the roadway; and
(2) Only one open roadway, which shall not exceed 16 feet wide, shall lead from solid pillars to the final stump of a pillar. Where posts are used as the sole means of roof support, the width of the roadway shall not exceed 14 feet.
(d) During open-end pillar extraction, at least 2 rows of breaker posts or equivalent support shall be installed on not more than 4-foot centers. These supports shall be installed between the lift to be started and the area where pillars have been extracted. These supports shall be maintained to within 7 feet of the face and the width of the roadway shall not exceed 16 feet. Where posts are used as the sole means of roof support, the width of the roadway shall not exceed 14 feet.
S 75.208 Warning devices.
Except during the installation of roof supports, the end of permanent roof support shall be posted with a readily visible warning, or a physical barrier shall be installed to impede travel beyond permanent support.
S 75.209 Automated Temporary Roof Support (ATRS) systems.
(a) Except in anthracite mines and as specified in paragraphs (b) and (c) of this section, an ATRS system shall be used with roof bolting machines and continuous-mining machines with integral roof bolters operated in a working section. The requirements of this paragraph shall be met according to the following schedule:
(1) All new machines ordered after March 28, 1988.
(2) All existing machines operated in mining heights of 36 inches or more after March 28, 1989; and
(3) All existing machines operated in mining heights of 30 inches or more but less than 36 inches after March 28, 1990. (b) After March 28, 1990 the use of ATRS systems with existing roof bolting machines and continuous-mining machines with integral roof bolters operated in a working section where the mining height is less than 30 inches shall be addressed in the roof control plan.
(c) Alternative means of temporary support shall be used, as specified in the roof control plan, when--
(1) Mining conditions or circumstances prevent the use of an ATRS system; or
(2) Temporary supports are installed in conjunction with an ATRS system.
(d) Persons shall work or travel between the support device of the ATRS system and another support, and the distance between the support device of the ATRS system and support to the left, right or beyond the ATRS system, shall not exceed 5 feet.
(e) Each ATRS system shall meet each of the following:
(1) The ATRS system shall elastically support a deadweight load measured in pounds of at least 450 times each square foot of roof intended to be supported, but in no case less than 11,250 pounds.
(2) The controls that position and set the ATRS system shall be--
(i) Operable from under permanently supported roof; or
(ii) Located in a compartment, which includes a deck, that provides the equipment operator with overhead and lateral protection, and has the structural capacity to elastically support a deadweight load of at least 18,000 pounds.
(3) All jacks affecting the capacity of the ATRS system and compartment shall have check valves or equivalent devices that will prevent rapid collapse in the event of a system failure.
(4) Except for the main tram controls, tram controls for positioning the equipment to set the ATRS system shall limit the speed of the equipment to a maximum of 80 feet-per-minute.
(f) The support capacity of each ATRS system and the structural capacity of each compartment shall be certified by a registered engineer as meeting the applicable requirements of paragraphs (e)(1) and (e)(2) of this section. The certifications shall be made available to an authorized representative of the Secretary, the State Mine Inspector and representative of the miners.
S 75.210 Manual installation of temporary support.
(a) When manually installing temporary support, only persons engaged in installing the support shall proceed beyond permanent support.
(b) When manually installing temporary supports, the first temporary support shall be set no more than 5 feet from a permanent roof support and the rib. All temporary supports shall be set so that the person installing the supports remains between the temporary support being set and two other sup- ports which shall be no more than 5 feet from the support being installed. Each temporary support shall be completely installed prior to installing the next temporary support.
(c) All temporary supports shall be placed on no more than 5-foot centers.
(d) Once temporary supports have been installed, work or travel beyond permanent roof support shall be done between temporary supports and the nearest permanent support or between other tempo- rary supports.
S 75.211 Roof testing and scaling.
(a) A visual examination of the roof, face and ribs shall be made immediately before any work is started in an area and thereafter as conditions warrant.
(b) Where the mining height permits and the visual examination does not disclose a hazardous condition, sound and vibration roof tests, or other equivalent tests, shall be made where supports are to be installed. When sound and vibration tests are made, they shall be conducted--
(1) After the ATRS system is set against the roof and before other support is installed; or
(2) Prior to manually installing a roof support. This test shall begin under supported roof and progress no further than the location where the next support is to be installed.
(c) When a hazardous roof, face, or rib condition is detected, the condition shall be corrected before there is any other work or travel in the affected area. If the affected area is left unattended, each entrance to the area shall be posted with a readily visible warning, or a physical barrier shall be installed to impede travel into the area.
(d) A bar for taking down loose material shall be available in the working place or on all face equipment except haulage equipment. Bars provided for taking down loose material shall be of a length and design that will allow the removal of loose material from a position that will not expose the person performing this work to injury from falling material.
S 75.212 Rehabilitation of areas with unsupported roof.
(a) Before rehabilitating each area where a roof fall has occurred or the roof has been removed by mining machines or by blasting--
(1) The mine operator shall establish the clean up and support procedures that will be followed;
(2) All persons assigned to perform rehabilitation work shall be instructed in the clean-up and support procedures; and
(3) Ineffective, damaged or missing roof support at the edge of the area to be rehabilitated shall be replaced or other equivalent support installed.
(b) All persons who perform rehabilitation work shall be experienced in this work or they shall be supervised by a person experienced in rehabilitation work who is designated by the mine operator.
(c) Where work is not being performed to rehabilitate an area in active workings where a roof fall has occurred or the roof has been removed by mining machines or by blasting, each entrance to the area shall be supported by at least one row of posts on not more than 5-foot centers, or equally effective support.
S 75.213 Roof support removal.
(a)(1) All persons who perform the work of removing permanent roof supports shall be super- vised by a management person experienced in removing roof supports.
(2) Only persons with at least one year of underground mining experience shall perform perma- nent roof support removal work.
(b) Prior to the removal of permanent roof supports, the person supervising roof support removal in accordance with paragraph (a)(1) of this section shall examine the roof conditions in the area where the supports are to be removed and designate each support to be removed.
(c)(1) Except as provided in paragraph (g) of this section, prior to the removal of permanent supports, a row of temporary supports on no more than 5-foot centers or equivalent support shall be installed across the opening within 4 feet of the supports being removed. Additional supports shall be installed where necessary to assure safe removal.
(2) Prior to the removal of roof bolts, temporary support shall be installed as close as practicable to each roof bolt being removed.
(d) Temporary supports installed in accordance with this section shall not be removed unless-
(1) Removal is done by persons who are in a remote location under supported roof; and
(2) At least two rows of temporary supports, set across the opening on no more than 5-foot centers, are maintained between the miners and the unsupported area.
(e) Each entrance to an area where supports have been removed shall be posted with a readily visible warning or a physical barrier shall be installed to impede travel into the area.
(f) Except as provided in paragraph (g) of this section, permanent support shall not be removed where--
(1) Roof bolt torque or tension measurements or the condition of conventional support indicate excessive loading;
(2) Roof fractures are present;
(3) There is any other indication that the roof is structurally weak; or
(4) Pillar recovery has been conducted.
(g) Permanent supports may be removed provided that:
(1) Removal is done by persons who are in a remote location under supported roof; and
(2) At least two rows of temporary supports, set across the opening on no more than 5-foot centers, are maintained between the miners and the unsupported area.
(h) The provisions of this section do not apply to removal of conventional supports for starting crosscuts and pillar splits or lifts except that prior to the removal of these supports an examination of the roof conditions shall be made.
S 75.214 Supplemental support materials, equipment and tools.
(a) A supply of supplementary roof support materials and the tools and equipment necessary to install the materials shall be available at a readily accessible location on each working section or within four crosscuts of each working section.
(b) The quantity of support materials and tools and equipment maintained available in accor- dance with this section shall be sufficient to support the roof if adverse roof conditions are encountered, or in the event of an accident involving a fall.
S 75.215 Longwall mining systems.
For each longwall mining section, the roof control plan shall specify--
(a) The methods that will be used to maintain a safe travelway out of the section through the tailgate side of the longwall; and
(b) The procedures that will be followed if a ground failure prevents travel out of the section through the tailgate side of the longwall.
S 75.220 Roof control plan.
(a)(1) Each mine operator shall develop and follow a roof control plan, approved by the District Manager, that is suitable to the prevailing geological conditions, and the mining system to be used at the mine. Additional measures shall be taken to protect persons if unusual hazards are encountered.
(2) The proposed roof control plan and any revisions to the plan shall be submitted, in writing, to the District Manager. When revisions to a roof control plan are proposed, only the revised pages need to be submitted unless otherwise specified by the District Manager. Upon approval a copy of the approved plan, and any changes, shall be file with the State Mine Inspector.
(b)(1) The mine operator will be notified in writing of the approval or denial of approval of a proposed roof control plan or proposed revision.
(2) When approval of a proposed plan or revision is denied, the deficiencies of the plan or revi- sion and recommended changes will be specified and the mine operator will be afforded an opportunity to discuss the deficiencies and changes with the District Manager.
(3) Before new support materials, devices or systems other than roof bolts and accessories, are used as the only means of roof support, the District Manager may require that their effectiveness be demonstrated by experimental installations.
(c) No proposed roof control plan or revision to a roof control plan shall be implemented before it is approved.
(d) Before implementing an approved revision to a roof control plan, all persons who are affected by the revision shall be instructed in its provisions.
(e) The approved roof control plan and any revisions shall be available to the miners and repre- sentative of miners at the mine.
(f) Existing roof control plans that conflict with this subpart C shall be revised to meet the re- quirements of this subpart C by September 28, 1988. This paragraph (f) shall expire March 28, 1989.
S 75.221 Roof control plan information.
(a) The following information shall be included in each roof control plan:
(1) The name and address of the company.
(2) The name, address, mine identification number and location of the mine.
(3) The name and title of the company official responsible for the plan.
(4) A typical columnar section of the mine strata which shall--
(i) Show the name and the thickness of the coalbed to be mined and any persistent partings;
(ii) Identify the type and show the thickness of each stratum up to and including the main roof above the coalbed and for distance of at least 10 feet below the coalbed; and
(iii) Indicate the maximum cover over the area to be mined.
(5) A description and drawings of the sequence of installation and spacing of supports for each method of mining used.
(6) When an ATRS system is used, the maximum distance that an ATRS system is to be set beyond the last row of permanent support.
(7) When tunnel liners or arches are to be used for roof support, specifications and installation procedures for the liners or arches.
(8) Drawings indicating the planned width of openings, size of pillars, method of pillar recovery, and the sequence of mining pillars.
(9) A list of all support materials required to be used in the roof, face and rib control system, including, if roof bolts are to be installed--
(i) The length, diameter, grade and type of anchorage unit to be used;
(ii) The drill hole size to be used; and
(iii) The installed torque or tension range for tensioned roof bolts.
(10) When mechanically anchored tensioned roof bolts are used, the intervals at which test holes will be drilled.
(11) A description of the method of protecting persons-
(i) From falling material at drift openings; and
(ii) When mining approaches within 150 feet of an outcrop.
(b) Each drawing submitted with a roof control plan shall contain a legend explaining all sym- bols used and shall specify the scale of the drawing which shall not be less than 5 feet to the inch or more than 20 feet to the inch.
(c) All roof control plan information, including drawings, shall be submitted on 8 1/2 by 11 inch paper, or paper folded to this size.
S 75.222 Roof control plan-approval criteria.
(a) This section sets forth the criteria that shall be considered on a mine-by-mine basis in the formulation and approval of roof control plans and revisions. Additional measures may be required in plans by the District Manager. Roof control plans that do not conform to the applicable criteria in this section may be approved by the District Manager, provided that effective control of the roof, face and ribs can be maintained.
(b) Roof Bolting. (1) Roof bolts should be installed on centers not exceeding 5 feet lengthwise and crosswise, except as specified in S 75.205.
(2) When tensioned roof bolts are used as a means of roof support, the torque or tension range should be capable of supporting roof bolt loads of at least 50 percent of either the yield point of the bolt or anchorage capacity of the strata, whichever is less.
(3) Any opening that is more than 20 feet wide should be supported by a combination of roof bolts and conventional supports.
(4) In any opening more than 20 feet wide--
(i) Posts should be installed to limit each roadway to 16 feet wide where straight and 18 feet wide where curved; and
(ii) A row of posts should be set for each 5 feet of space between the roadway posts and the ribs.
(5) Openings should not be more than 30 feet wide.
(c) Installation of roof support using mining machines with integral roof bolters. (1) Before an intersection or pillar split is started, roof bolts should be installed on at least 5-foot centers where the work is performed.
(2) Where the roof is supported by only two roof bolts crosswise, openings should not be more than 16 feet wide.
(d) Pillar recovery. (1) During development, any dimension of a pillar should be at least 20 feet.
(2) Pillar splits and lifts should not be more than 20 feet wide.
(3) Breaker posts should be installed on not more than 4-foot centers.
(4) Roadside-radius (turn) posts, or equivalent support, should be installed on not more than 4-foot centers leading into each pillar split or lift.
(5) Before full pillar recovery is started in areas where roof bolts are used as the only means of roof support and openings are more than 16 feet wide, at least one row of posts should be installed to limit the roadway width to 16 feet. These posts should be-
(i) Extended from the entrance to the split through the intersection outby the pillar in which the split or lift is being made; and
(ii) Spaced on not more than 5-foot centers.
(e) Unsupported openings at intersections. Openings that create an intersection should be perma- nently supported or at least one row of temporary supports should be installed on not more than 5-foot centers across the opening before any other work or travel in the intersection.
(f) ATRS systems in working sections where the mining height is below 30 inches. In working sections where the mining height is below 30 inches, an ATRS system should be used to the extent practicable during the installation of roof bolts with roof bolting machines and continuous-mining machines with integral roof bolters.
(g) Longwall mining systems. (1) Systematic supplemental support should be installed through- out--
(i) The tailgate entry of the first longwall panel prior to any mining; and
(ii) In the proposed tailgate entry of each subsequent panel in advance of the frontal abutment stresses of the panel being mined.
(2) When a ground failure prevents travel out of the section through the tailgate side of the longwall section, the roof control plan should address--
(i) Notification of miners that the travelway is blocked;
(ii) Re-instruction of miners regarding escapeways and escape procedures in the event of an emergency;
(iii) Re-instruction of miners on the availability and use of self-contained self-rescue devices;
(iv) Monitoring and evaluation of the air entering the longwall section;
(v) Location and effectiveness of the two-way communication systems; and
(vi) A means of transportation from the section to the main line.
(3) The plan provisions addressed by paragraph (g)(2) of this section should remain in effect until travelway is reestablished on the tailgate side of a longwall section.
S 75.223 Evaluation and revision of roof control plan.
(a) Revisions of the roof control plan shall be proposed by the operator-
(1) When conditions indicate that the plan is not suitable for controlling the roof, face, ribs, or coal or rock bursts; or
(2) When accident and injury experience at the mine indicates the plan is inadequate. The acci- dent and injury experience at each mine shall be reviewed at least every six months.
(b) Each unplanned roof fall and rib fall and coal or rock burst that occurs in the active workings shall be plotted on a mine map if it--
(1) Is above the anchorage zone where roof bolts are used;
(2) Impairs ventilation;
(3) Impedes passage of persons;
(4) Causes miners to be withdrawn from the area affected; or
(5) Disrupts regular mining activities for more than one hour.
(c) The mine map on which roof falls are plotted shall be available at the mine site for inspection by authorized representatives of the Secretary, the State Mine Inspector and representatives of miners at the mine.
(d) The roof control plan for each mine shall be reviewed every six months by an authorized representative of the Secretary. This review shall take into consideration any falls of the roof, face and ribs and the adequacy of the support systems used at the time.
Subpart D--Ventilation
75.300 Scope.
This subpart sets requirements for underground coal mine ventilation.
75.301 Definitions.
75.302 Main mine fans.
75.311 Main mine fan operation.
(a) Main mine fans shall be continuously operated, except as otherwise approved in the ventila- tion plan, or when intentionally stopped for testing of automatic closing doors and automatic fan signal devices, maintenance or adjustment of the fan, or to perform maintenance or repair work underground that cannot otherwise be made while the fan is operating.
(b) Except as provided in paragraph (c) of this section, when a main mine fan is intentionally stopped and the ventilating quantity provided by the fan is not maintained by a back-up fan system-
(1) Only persons necessary to evaluate the effect of the fan stoppage or restart, or to perform maintenance or repair work that cannot otherwise be made while the fan is operating, shall be permitted underground;
(2) Mechanized equipment shall be shut off before stopping the fan; and
(3) Electric power circuits entering underground areas of the mine shall be deenergized.
(c) When a back-up fan system is used that does not provide the ventilating quantity provided by the main mine fan, persons may be permitted in the mine and electric power circuits may be energized as specified in the approved ventilation plan.
(d) If an unusual variance in the mine ventilation pressure is observed, or if an electrical or mechanical deficiency of a main mine fan is detected, the mine foreman or equivalent mine official, or in the absence of the mine foreman or equivalent mine official, a designated certified person acting for the mine foreman or equivalent mine official shall be notified immediately, and appropriate action or repairs shall be instituted promptly.
(e) While persons are underground, a responsible person designated by the operator shall always be at a surface location where each main mine fan signal can be seen or heard.
(f) The area within 100 feet of main mine fans and intake air openings shall be kept free of combustible material, unless alternative precautions necessary to provide protection from fire or other products of combustion are approved in the ventilation plan.
(g) If multiple mine fans are used, the mine ventilation system shall be designed and maintained to eliminate areas without air movement.
(h) Any atmospheric monitoring system operated during fan stoppages shall be intrinsically safe.
75.312 Main mine fan examinations and records.
75.313 Main mine fan stoppage with persons underground.
75.321 Air quality.
75.322 Harmful quantities of noxious gases.
Concentrations of noxious or poisonous gases, other than carbon dioxide, shall not exceed the threshold limit values (TLV) as specified and applied by the American Conference of Governmental Industrial Hygienists in -Threshold Limit Values for Substance in Workroom Air- (1972). Detectors or laboratory analysis of mine air samples shall be used to determine the concentrations of harmful, nox- ious, or poisonous gases. This incorporation by reference has been approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR Part 51. Copies are available from the Mine Safety and Health Administration, Department of Labor, 4015 Wilson Boulevard, Arlington, VA 22203 and at every Coal Mine Health and Safety District and Subdistrict Office. The material is avail- able for examination at the Office of the Federal Register, 800 N. Capitol Street, NW., 7th Floor, Suite 700, Washington, D.C. 20408
75.323 Actions for excessive methane.
75.325 Air quantity.
75.326 Mean entry air velocity.
In exhausting face ventilation systems, the mean entry air velocity shall be at least 60 feet per minute reaching each working face where coal is being cut, mined, drilled for blasting, or loaded, and to any other working places as required in the approved ventilation plan. A lower mean entry air velocity may be approved in the ventilation plan if the lower velocity will maintain methane and respirable dust concentrations in accordance with the applicable levels. Mean entry air velocity shall be determined at or near the inby end of the line curtain, ventilation tubing, or other face ventilation control devices.
75.327 Air courses and trolley haulage systems.
75.330 Face ventilation control devices.
75.331 Auxiliary fans and tubing.
75.332 Working sections and working places.
75.333 Ventilation controls.
75.334 Worked-out areas and areas where pillars are being recovered.
75.340 Underground electrical installations.
75.341 Direct-fired intake air heaters.
75.342 Methane monitors.
75.344 Compressors.
75.345 Housing of underground compressor stations.
Underground compressor stations shall be housed in fireproof structures or areas.
75.350 Air courses and belt haulage entries.
75.351 Atmospheric monitoring system (AMS).
75.352 Return air courses.
Entries used as return air courses shall be separated from belt haulage entries by permanent ventilation controls.
75.360 Preshift examination.
75.361 Supplemental examination.
75.362 On-shift examination.
75.363 Hazardous conditions; posting, correcting and recording.
75.364 Weekly examination.
75.370 Mine ventilation plan; contents.
75.371 Mine ventilation plan; contents.
75.372 Mine ventilation map.
75.373 Reopening mines.
After a mine is abandoned or declared inactive, and before it is reopened, mining operations shall not begin until MSHA has been notified and has completed an inspection.
75.380 Escapeways; bituminous and lignite mines.
75.381 Escapeways; anthracite mines.
75.382 Mechanical escape facilities.
75.383 Escapeway maps and drills.
75.384 Longwall and shortwall travelways.
75.385 Opening new mines.
When new mines are opened, no more than 20 miners at a time shall be allowed in any mine until connection has been made between the mine openings, and these connections shall be made as soon as possible.
75.386 Final mining of pillars.
When only one mine opening is available due to final mining of pillars, no more than 20 miners at a time shall be allowed in the mine, and the distance between the mine opening and working face shall not exceed 500 feet.
75.388 Boreholes in advance of mining.
75.389 Mining into inaccessible areas.
(a)(1) The operator shall develop and follow a plan for mining into areas penetrated by boreholes drilled under 75.388.
(2) Mining shall not resume into any area penetrated by boreholes until conditions in the pen- etrated area can be determined under 75.388 and the plan for mining-through into the area has been approved by the district manager.
(3) A copy of the procedures to be followed shall be posted near the site of the mining-through operations and the operator shall explain these procedures to all miners involved in the operations.
(b) The procedures specified in the plan shall include-
(1) The method of ventilation, ventilation controls, and the air quantities and velocities in the affected working section and working place;
(2) Dewatering procedures to be used if a penetrated area contains a water accumulation; and
(3) The procedures and precautions to be followed during mining- through operations.
(c) Except for routine mining-through operations that are part of a retreat section ventilation system approved in accordance with 75.371(f) and (x), the following provisions shall apply:
(1) Before and during mining-through operations, a certified person shall perform air quality tests at intervals and at locations necessary to protect the safety of the miners.
(2) During mining-through operations, only persons involved in these operations shall be permit- ted in the mine; and
(3) After mining-through, a certified person shall determine that the affected areas are safe before any persons enter the underground areas of the mine.
Subpart E--Combustible Materials and Rock Dusting
S 75.400 Accumulation of combustible materials.
Coal dust, including float coal dust deposited on rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be permitted to accumulate in active workings, or on diesel-powered equipment and electric equipment therein.
S 75.400-1 Definitions.
(a) The term "coal dust" means particles of coal that can pass a No. 20 sieve.
(b) The term "float coal dust" means the coal dust consisting of particles of coal that can pass a No. 200 sieve.
(c) The term "loose coal" means coal fragments larger in size than coal dust.
S 75.400-2 Cleanup program.
A program for regular cleanup and removal of accumulations of coal and float coal dusts, loose coal, and other combustibles shall be established and maintained. Such program shall be available to the Secretary or authorized representative and the State Mine Inspector.
S 75.401 Abatement of dust; water or water with a wetting agent.
[Statutory Provision]
Where underground mining operations in active workings create or raise excessive amounts of dust, water or water with a wetting agent added to it, or other no less effective methods approved by the Secretary or his authorized representative, shall be used to abate such dust. In working places, particu- larly in distances less than 40 feet from the face, water, with or without a wetting agent, or other no less effective methods approved by the Secretary or his authorized representative, shall be applied to coal dust on the ribs, roof, and floor to reduce dispersibility and to minimize the explosion hazard.
S 75.401-1 Excessive amounts of dust.
The term "excessive amounts of dust" means coal and float coal dust in the air in such amounts as to create the potential of an explosion hazard.
S 75.402 Rock dusting.
[Statutory Provision]
All underground areas of a coal mine, except those areas in which the dust is too wet or too high in incombustible content to propagate an explosion, shall be rock dusted to within 40 feet of all working faces, unless such areas are inaccessible or unsafe to enter or unless the Secretary or his authorized representative permits an exception upon his finding that such exception will not pose a hazard to the miners. All crosscuts that are less than 40 feet from a working face shall also be rock dusted.
S 75.402-1 Definition.
The term "too wet" means that sufficient natural moisture is retained by the dust that when a ball of finely divided material is squeezed in the hands water is exuded.
S 75.402-2 Exceptions.
Exceptions granted under S 75.402 by the Secretary or his authorized representative shall be reviewed periodically.
S 75.403 Maintenance of incombustible content of rock dust.
[Statutory Provision]
Where rock dust is required to be applied, it shall be distributed upon the top, floor, and sides of all underground areas of a coal mine and maintained in such quantities that the incombustible content of the combined coal dust, rock dust, and other dust shall be not less than 65 per centum, but the incombus- tible content in the return aircourses shall be no less than 80 per centum. Where methane is present in any ventilating current, the per centum of incombustible content of such combined dusts shall be in- creased 1.0 and 0.4 per centum for each 0.1 per centum of methane where 65 and 80 per centum, respec- tively, of incombustibles are required.
S 75.403-1 Incombustible content.
Moisture contained in the combined coal dust, rock dust and other dusts shall be considered as a part of the incombustible content of such mixture.
S 75.404 Exemption of anthracite mines.
[Statutory Provision]
Sections 75.401, 75.402, and 75.403 shall not apply to underground anthracite mines. Subpart F--Electrical Equipment-General
S 75.500 Permissible electric equipment.
[Statutory Provision]
On and after March 30, 1971:
(a) All junction or distribution boxes used for making multiple power connections inby the last open crosscut shall be permissible;
(b) All handheld electric drills, blower and exhaust fans, electric pumps, and such other low horsepower electric face equipment as the Secretary may designate on or before May 30, 1970, which are taken into or used inby the last open crosscut of any coal mine shall be permissible;
(c) All electric face equipment which is taken into or used inby the last open crosscut of any coal mine classified under any provision of law as gassy prior to March 30, 1970, shall be permissible; and
(d) All other electric face equipment which is taken into or used inby the last crosscut of any coal mine, except a coal mine referred to in S 75.501, which has not been classified under any provision of law as a gassy mine prior to March 30, 1970, shall be permissible.
S 75.500-1 Other low horsepower electric face equipment.
Other low horsepower electric face equipment designated pursuant to the provisions of S 75.500(b) is all other electric-driven mine equipment, except low horsepower rock dusting equipment, and employs an electric current supplied by either a power conductor or battery and consumes not more than 2,250 watts of electricity and which is taken into or used inby the last open crosscut.
S 75.501 Permissible electric face equipment; coal seams above water table.
[Statutory Provision]
On and after March 30, 1974, all electric face equipment, other than equipment referred to in paragraph (b) of S 75.500, which is taken into and used inby the last open crosscut of any coal mine which is operated entirely in coal seams located above the water table and which has not been classified under any provision of law as a gassy mine prior to March 30, 1970, and in which one or more openings were made prior to December 30, 1969, shall be permissible.
S 75.501-1 Coal seams above the water table.
As used in S 75.501, the phrase "coal seams above the water table" means coal seams in a mine which are located at an elevation above a river or the tributary of a river into which a local surface water system naturally drains.
S 75.501-2 Permissible electric face equipment.
(a) On and after March 30, 1971, in mines operated entirely in coal seams which are located at elevations above the water table:
(1) All junction or distribution boxes used for making multiple power connections inby the last open crosscut shall be permissible; and
(2) All handheld electric drills, blower and exhaust fans, electric pumps, and all other electric-driven mine equipment, except low horsepower rock dusting equipment, that employs an electric current supplied by either a power conductor or battery and consumes not more than 2,250 watts of electricity, which is taken into or used inby the last open crosscut shall be permissible.
(b) On and after March 30, 1974, in mines operated entirely in coal seams which are located at elevations above the water table, all electric face equipment which is taken into or used inby the last crosscut shall be permissible.
S 75.501-3 New openings; mines above water table and never classed gassy.
(a) Where a new opening(s) is proposed to be developed by shaft, slope, or drift from the surface to, or in, any coalbed and the operator considers such proposed new opening(s) to be a part of a mine coming under section 305(a)(2) of the Act and S75.501 the operator shall so notify the District Manager for the District in which the mine is located and the State Mine Inspector in writing prior to the date any actual development (in coal) through such opening(s) is undertaken. Such notification shall include the following information:
(1) Name, address, and identification number of the existing mine.
(2) A current map of the existing mine clearly setting out the proposed new opening(s), mining plan and planned interconnection, if any, with existing workings.
(3) A statement as to when the operator obtained the right to mine the coal which the proposed new opening(s) will traverse.
(4) The name of the coalbeds currently being mined and those which the new opening(s) will traverse.
(5) The expected life of the mine.
(6) The reason(s) for the proposed new opening(s) (for example, haulage, ventilation, drainage, to avoid bad roof, escapeway). The District Manager shall require submission of any additional informa- tion he considers pertinent.
(b) The District Manager shall make a determination based on all of the information submitted by the operator as to whether the proposed new opening(s) will be considered as a part of the existing mine or as a new mine. The following guidelines and criteria shall be used by the District Manager in making his determination:
(1) The effect that the proposed new opening(s) will have on the safety of the men working in the existing mine shall be considered of primary importance.
(2) Whether the operator had a right to mine the coal which the proposed new openings will traverse prior to the date of enactment of the Act (December 30, 1969) and whether the original mining plan included mining such coal.
(3) Whether, in accordance with the usual mining practices common to the particular district, the proposed new openings would have been considered a new mine or part of the existing mine. A number of factors will be considered including, but not limited to:
(i) The relationship between the coalbeds currently being mined, and those proposed to be mined;
(ii) The distance between existing openings and the proposed new opening(s);
(iii) The projected time elapsing between the start of the new opening(s) and planned intercon- nection, if any, with the existing mine; and
(iv) The projected tonnage of coal which is expected to be mined prior to interconnection where interconnection is planned. The District Manager shall notify the operator in writing within 30 days of receiving all of the information, required and requested, of his determination. No informal notification shall be given.
(c) All new opening(s) shall be operated as a new mine prior to receiving a written notification from the District Manager that such new opening(s) will be considered part of an existing mine coming under section 305(a)(2) of the Act and S 75.501.
(d) Nothing in this S 75.501-3 shall be construed to relieve the operator from compliance with any of the mandatory standards contained in this part 75.
S 75.502 Permits for noncompliance.
An operator need not comply with paragraph (d) of S 75.500 or with S 75.501 during the period of time specified in a permit issued by the Interim Compliance Panel established by the Act.
S 75.503 Permissible electric face equipment; maintenance.
[Statutory Provisions]
The operator of each coal mine shall maintain in permissible condition all electric face equip- ment required by SS 75.500, 75.501, 75.504 to be permissible which is taken into or used inby the last open crosscut of any such mine.
S 75.503-1 Statement listing all electric face equipment.
Each operator of a coal mine shall complete and file Mine Safety and Health Administration Form No. 6-1496 entitled "Coal Operator's Electrical Survey" and Form 6-1496 Supplemental entitled "Operator's Survey of Electrical Face Equipment." Forms may be obtained from any Coal Mine Safety District Office or Subdistrict Office of the Mine Safety and Health Administration. Separate forms shall be filed for each mine. Copies one and two of the completed form shall be filed with the Coal Mine District or Subdistrict Manager for the district in which each mine is located on or before May 30, 1970.
An operator must list all electric face equipment being used at each mine as of the time of filing, all such equipment being repaired, and all standby electric equipment stored at or in the mine which the operator intends to use as face equipment.
S 75.504 Permissibility of new, replacement, used, reconditioned, additional, and rebuilt electric face equipment.
On and after March 30, 1971, all new, replacement, used, reconditioned, and additional electric face equipment used in any mine referred to in SS 75.500, 75.501, and 75.503 shall be permissible and shall be maintained in a permissible condition, and in the event of any major overhaul of any item of electric face equipment in use on or after March 30, 1971, such equipment shall be put in, and thereafter maintained in, a permissible condition, unless in the opinion of the Secretary, such equipment or neces- sary replacement parts are not available.
S 75.505 Mines classed gassy; use and maintenance of permissible electric face equipment.
[Statutory Provision]
Any coal mine which, prior to March 30, 1970, was classed gassy under any provision of law and was required to use permissible electric face equipment and to maintain such equipment in a permissible condition shall continue to use such equipment and to maintain such equipment in such condition.
S 75.506 Electric face equipment; requirements for permissibility.
(a) Electric-driven mine equipment and accessories manufactured on or after March 30, 1973, will be permissible electric face equipment only (1) if they are fabricated, assembled, or built under an approval, or any extension thereof, issued by the Bureau of Mines or the Mine Safety and Health Admin- istration in accordance with schedule 2G, or any subsequent Bureau of Mines schedule promulgated by the Secretary after March 30, 1970, which amends, modifies, or supersedes the permissibility require- ments of schedule 2G, and (2) if they are maintained in a permissible condition.
(b) Except as provided in paragraph (c) of this S 75.506 electric-driven mine equipment and accessories manufactured prior to March 30, 1973, will be permissible electric face equipment (1) if they were fabricated, assembled, or built under an approval, or any extension thereof, issued by the Bureau of Mines in accordance with the schedules set forth below, and (2) if they are maintained in a permissible condition.
Bureau of Mines Schedule 2D, May 23, 1936;
Bureau of Mines Schedule 2E, February 15, 1945;
Bureau of Mines Schedule 2F, August 3, 1955; and
Bureau of Mines Schedule 2G, March 19, 1968.
Copies of these schedules are available at all Coal Mine Safety District and Subdistrict Offices of the Bureau of Mines.
(c) Electric driven mine equipment and accessories bearing the Bureau of Mines approval num- bers listed in Appendix A to this subpart are permissible electric face equipment only if they are main- tained in a permissible condition.
(d) Electric cap lamps, electric mine lamps other than standard cap lamps, flame safety lamps, portable methane detectors, telephones and signaling devices, single- and multiple-shot blasting units, lighting equipment for illuminating underground mines, and methane-monitoring systems will be per- missible electric face equipment only (1) if they are approved under the appropriate Bureau of Mines schedule applicable to such equipment and (2) if they are in permissible condition. The Bureau of Mines schedules referred to, dates issued, and the appropriate parts of this chapter are:
Electric Cap Lamps, Bureau of Mines Schedule 6D, August 26, 1939 (part 19);
Electric Mine Lamps Other than Standard Cap Lamps, Bureau of Mines Schedule 10C, May 17, 1938 (part 20);
Flame Safety Lamps, Bureau of Mines Schedule 7C, August 30, 1935 (part 21);
Portable Methane Detectors, Bureau of Mines Schedule 8C, October 31, 1935 (part 22);
Telephone and Signaling Devices, Bureau of Mines Schedule 9B, October 25, 1938 (part 23);
Single Shot Blasting Units, Bureau of Mines Schedule 12D, November 27, 1945 (part 24);
Multiple Shot Blasting Units, Bureau of Mines Schedule 16E, May 19, 1960 (part 25);
Lighting Equipment for Illuminating Underground Workings, Bureau of Mines Schedule 29A, December 2, 1958 (part 26); and
Methane-Monitoring Systems, Bureau of Mines Schedule 32A, July 27, 1966 (part 27).
S 75.506-1 Electric face equipment; permissible condition; maintenance requirements.
(a) Except as provided in paragraph (b) of this section, electric face equipment which meets the requirements for permissibility set forth in S 75.506 will be considered to be in permissible condition only if it is maintained so as to meet the requirements for permissibility set forth in the Bureau of Mines schedule under which such electric face equipment was initially approved, or, if the equipment has been modified, it is maintained so as to meet the requirements of the schedule under which such modification was approved.
(b) Electric face equipment bearing the Bureau of Mines approval number listed in Appendix A of this subpart will be considered to be in permissible condition only if it is maintained so as to meet the requirements for permissibility set forth in Bureau of Mines Schedule 2D or, if such equipment has been modified, it is maintained so as to meet the requirements of the schedule under which the modification was approved.
(c) Notwithstanding the provisions of paragraphs (a) and (b) of this section, where the minimum requirements for permissibility set forth in the appropriate Bureau of Mines schedule under which such equipment or modifications were approved have been superseded by the requirements of this part 75, the latter requirements shall be applicable.
S 75.507 Power connection points.
[Statutory Provisions]
Except where permissible power connection units are used, all power-connection points outby the last open crosscut shall be in intake air.
S 75.507-1 Electric equipment other than power-connection points; outby the last open crosscut; return air; permissibility requirements.
(a) All electric equipment, other than power-connection points, used in return air outby the last open crosscut in any coal mine shall be permissible except as provided in paragraphs (b) and (c) of this section.
(b) Notwithstanding the provisions of paragraph (a) of this section, in any coal mine where nonpermissible electric face equipment may be taken into or used inby the last open crosscut until March 30, 1974, such nonpermissible electric face equipment may be used in return air outby the last open crosscut.
(c) Notwithstanding the provisions of paragraph (a) of this section, in any coal mine where a permit for noncompliance is in effect, nonpermissible electric face equipment specified in such permit for noncompliance may be used in return air outby the last open crosscut for the duration of such permit.
S 75.508 Map of electrical system.
[Statutory Provisions]
The location and the electrical rating of all stationary electric apparatus in connection with the mine electric system, including permanent cables, switchgear, rectifying substations, transformers, permanent pumps, and trolley wires and trolley feeder wires, and settings of all direct-current circuit breakers protecting underground trolley circuits, shall be shown on a mine map. Any changes made in a location, electric rating, or setting shall be promptly shown on the map when the change is made. Such map shall be available to an authorized representative of the Secretary and to the miners in such mine.
S 75.508-1 Mine tracks.
When mine track is used as a conductor of a trolley system, the location of such track shall be shown on the map required by S 75.508, with a notation of the number of rails and the size of such track expressed in pounds per yard.
S 75.508-2 Changes in electric system map; recording.
Changes made in the location, electrical rating or setting within the mine electrical system shall be recorded on the map of such system no later than the end of the next workday following completion of such changes.
S 75.509 Electric power circuit and electric equipment; deenergization.
[Statutory Provisions]
All power circuits and electric equipment shall be deenergized before work is done on such circuits and equipment, except when necessary for trouble shooting or testing.
S 75.510 Energized trolley wires; repair.
[Statutory Provisions]
Energized trolley wires may be repaired only by a person trained to perform electrical work and to maintain electrical equipment and the operator of a mine shall require that such person wear approved and tested insulated shoes and wireman's gloves.
S 75.510-1 Repair of energized trolley wires; training.
The training referred to in S 75.510 must include training in the repair and maintenance of live trolley wires, and in the hazards involved in making such repairs, and in the limitations of protective clothing used to protect against such hazards.
S 75.511 Low-, medium-, or high-voltage distribution circuits and equipment; repair.
[Statutory Provision]
No electrical work shall be performed on low-, medium-, or high-voltage distribution circuits or equipment, except by a qualified person or by a person trained to perform electrical work and to main- tain electrical equipment under the direct supervision of a qualified person. Disconnecting devices shall be locked out and suitably tagged by the persons who perform such work, except that in cases where locking out is not possible, such devices shall be opened and suitably tagged by such persons. Locks or tags shall be removed only by the persons who installed them or, if such persons are unavailable, by persons authorized by the operator or his agent.
S 75.511-1 Qualified person.
To be a qualified person within the meaning of S 75.511, an individual must meet the require- ments of S 75.153.
S 75.512 Electric equipment; examination, testing and maintenance.
[Statutory Provision]
All electric equipment shall be frequently examined, tested, and properly maintained by a quali- fied person to assure safe operating conditions. When a potentially dangerous condition is found on electric equipment, such equipment shall be removed from service until such condition is corrected. A record of such examinations shall be kept and made available to an authorized representative of the Secretary and to the miners in such mine.
S 75.512-1 Qualified person.
To be a qualified person within the meaning of S 75.512, an individual must meet the require- ments of S 75.153.
S 75.512-2 Frequency of examinations.
The examinations and tests required by S 75.512 shall be made at least weekly. Permissible equipment shall be examined to see that it is in permissible condition.
S 75.513 Electric conductor; capacity and insulation.
[Statutory Provision]
All electric conductors shall be sufficient in size and have adequate current carrying capacity and be of such construction that a rise in temperature resulting from normal operation will not damage the insulating materials.
S 75.513-1 Electric conductor; size.
An electric conductor is not of sufficient size to have adequate carrying capacity if it is smaller than is provided for in the National Electric Code, 1968. In addition, equipment and trailing cables that are required to be permissible must meet the requirements of the appropriate schedules of the Bureau of Mines.
S 75.514 Electrical connections or splices; suitability.
[Statutory Provision]
All electrical connections or splices in conductors shall be mechanically and electrically efficient, and suitable connectors shall be used. All electrical connections or splices in insulated wire shall be reinsulated at least to the same degree of protection as the remainder of the wire.
S 75.515 Cable fittings; suitability.
S 75.516 Power wires; support.
[Statutory Provision]
All power wires (except trailing cables on mobile equipment, specially designed cables conduct- ing high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.
S 75.516-1 Installed insulators.
Well-insulated insulators is interpreted to mean well-installed insulators. Insulated J-hooks may be used to suspend insulated power cables for temporary installation not exceeding 6 months and for permanent installation of control cables such as may be used along belt conveyors.
S 75.516-2 Communication wires and cables; installation; insulation; support.
(a) All communication wires shall be supported on insulated hangers or insulated J-hooks.
(b) All communication cables shall be insulated as required by S 75.517-1, and shall either be supported on insulated or uninsulated hangers or J-hooks, or securely attached to messenger wires, or buried, or otherwise protected against mechanical damage in a manner approved by the Secretary or his authorized representative.
(c) All communication wires and cables installed in track entries shall, except when a communi- cation cable is buried in accordance with paragraph (b) of this section, be installed on the side of the entry opposite to trolley wires and trolley feeder wires. Additional insulation shall be provided for communication circuits at points where they pass over or under any power conductor.
(d) For purposes of this section, communication cable means two or more insulated conductors covered by an additional abrasion-resistant covering.
S 75.517 Power wires and cables; insulation and protection.
[Statutory Provisions]
Power wires and cables, except trolley wires, trolley feeder wires, and bare signal wires, shall be insulated adequately and fully protected.
S 75.517-1 Power wires and cables; insulation and protection.
Power wires and cables installed on or after March 30, 1970, shall have insulation with a dielec- tric strength at least equal to the voltage of the circuit.
S 75.517-2 Plans for insulation of existing bare power wires and cables.
(a) On or before December 31, 1970, plans for the insulation of existing bare power wires and cables installed prior to March 30, 1970, shall be filed with the District Manager of the Coal Mine Safety District in which the mine is located to permit approval and prompt implementation of such plans.
(b) The appropriate District Manager shall notify the operator in writing of the approval of a proposed insulation plan. If revisions are required for approval, the changes required will be specified.
(c) An insulation plan shall include the following information:
(1) Name and address of the company, the mine and the responsible officials;
(2) Map or diagram indicating location of power wires and cables required to be insulated;
(3) Total length of bare power wires and cables required to be insulated;
(4) Schedule for the replacement or insulation of bare power wires and cables;
(5) Type of insulation to be used and the voltage rating as indicated by the manufacturer.
(d) The District Manager shall be guided by the following criteria in approving insulation plans on a mine-by-mine basis. Insulation not conforming to these criteria may be approved provided the operator can satisfy the Mine Safety and Health Administration that the insulation will provide no less than the same measure of protection.
(1) Insulation shall be adequate for the applied voltage of the circuit.
(2) When tubing is used to insulate existing power wires and cables, it shall have a dielectric strength at least equal to the voltage of the circuit. When the tubing is split for purposes of installation, the joints shall be effectively sealed. The butt ends may be sealed with a moisture resistant insulating tape.
(3) When tape is used to insulate existing power wires and cables, it shall be applied half-lapped and one thickness of the tape shall have a dielectric strength at least equal to the voltage of the circuit. The tape shall be self-adhesive and moisture resistant.
S 75.518 Electric equipment and circuits; overload and short circuit protection.
S 75.518-1 Electric equipment and circuits; overload and short circuit protection; minimum requirements.
A device to provide either short circuit protection or protection against overload which does not conform to the provisions of the National Electric Code, 1968, does not meet the requirement of S 75.518. In addition, such devices on electric face equipment and trailing cables that are required to be permissible must meet the requirements of the applicable schedules of the Bureau of Mines.
S 75.518-2 Incandescent lamps, overload and short circuit protection.
Incandescent lamps installed along haulageways and at other locations, not contacting combus- tible material, and powered from trolley or direct current feeder circuits, need not be provided with separate short circuit or overload protection, if the lamp is not more than 8 feet in distance from such circuits.
S 75.519 Main power circuits; disconnecting switches.
[Statutory Provision]
In all main power circuits, disconnecting switches shall be installed underground within 500 feet of the bottoms of shafts and boreholes through which main power circuits enter the underground area of the mine and within 500 feet of all other places where main power circuits enter the underground area of the mine.
S 75.519-1 Main power circuits; disconnecting switches; locations.
Section 75.519 requires (a) that a disconnecting switch be installed on the surface at a point within 500 feet of the place where the main power circuit enters the underground area of a mine, and (b) that, in an instance on which a main power circuit enters the underground area through a shaft or bore- hole, a disconnecting switch be installed underground within 500 feet of the bottom of the shaft or borehole.
S 75.520 Electric equipment; switches.
[Statutory Provision]
All electric equipment shall be provided with switches or other controls that are safely designed, constructed, and installed.
S 75.521 Lightning arresters; ungrounded and exposed power conductors and telephone wires.
Each ungrounded, exposed power conductor and each ungrounded, exposed telephone wire that leads underground shall be equipped with suitable lightning arresters of approved type within 100 feet of the point where the circuit enters the mine. Lightning arresters shall be connected to a low resistance grounding medium on the surface which shall be separated from neutral grounds by a distance of not less than 25 feet.
S 75.522 Lighting devices.
[Statutory Provision]
No device for the purpose of lighting any coal mine which has not been approved by the Secre- tary or his authorized representative shall be permitted in such mine.
S 75.522-1 Incandescent and fluorescent lamps.
(a) Except for areas of a coal mine inby the last open crosscut, incandescent lamps may be used to illuminate underground areas. When incandescent lamps are used in a track entry or belt entry or near track entries to illuminate special areas other than structures, the lamps shall be installed in weather-proof sockets located in positions such that the lamps will not come in contact with any com- bustible material. Lamps used in all other places must be of substantial construction and be fitted with a glass enclosure.
(b) Incandescent lamps within glass enclosures or fluorescent lamps may be used inside under- ground structures (except magazines used for the storage of explosives and detonators). In underground structures lighting circuits shall consist of cables installed on insulators or insulated wires installed in metallic conduit or metallic armor.
S 75.523 Electric face equipment; deenergization.
[Statutory Provision]
An authorized representative of the Secretary may require in any mine that electric face equip- ment be provided with devices that will permit the equipment to be deenergized quickly in the event of an emergency.
S 75.523-1 Deenergization of self-propelled electric face equipment installation requirements.
(a) Except as provided in paragraphs (b) and (c) of this section, all self-propelled electric face equipment which is used in the active workings of each underground coal mine on and after March 1, 1973, shall, in accordance with the schedule of time specified in paragraphs (a)(1) and (2) of this section, be provided with a device that will quickly deenergize the tramming motors of the equipment in the event of an emergency. The requirements of this paragraph (a) shall be met as follows:
(1) On and after December 15, 1974, for self-propelled cutting machines, shuttle cars, battery-powered machines, and roof drills and bolters;
(2) On and after February 15, 1975, for all other types of self-propelled electric face equipment.
(b) Self-propelled electric face equipment that is equipped with a substantially constructed cab which meets the requirements of this part, shall not be required to be provided with a device that will quickly deenergize the tramming motors of the equipment in the event of an emergency.
(c) An operator may apply to the Director of Technical Support, Mine Safety and Health Admin- istration, Department of Labor, 4015 Wilson Boulevard, Arlington, Va. 22203 for approval of the instal- lation of devices to be used in lieu of devices that will quickly deenergize the tramming motors of self-propelled electric face equipment in the event of an emergency. The Director of Technical Support may approve such devices if he determines that the performance thereof will be no less effective than the performance requirements specified in S 75.523-2.
S 75.523-2 Deenergization of self-propelled electric face equipment; performance requirements.
(a) Deenergization of the tramming motors of self-propelled electric face equipment, required by paragraph (a) of S 75.523-1, shall be provided by:
(1) Mechanical actuation of an existing pushbutton emergency stopswitch,
(2) Mechanical actuation of an existing lever emergency stopswitch, or
(3) The addition of a separate electromechanical switch assembly.
(b) The existing emergency stopswitch or additional switch assembly shall be actuated by a bar or lever which shall extend a sufficient distance in each direction to permit quick deenergization of the tramming motors of self-propelled electric face equipment from all locations from which the equipment can be operated.
(c) Movement of not more than 2 inches of the actuating bar or lever resulting from the applica- tion of not more than 15 pounds of force upon contact with any portion of the equipment operator's body at any point along the length of the actuating bar or lever shall cause deenergization of the tramming motors of the self-propelled electric face equipment.
S 75.523-3 Automatic emergency-parking brakes.
(a) Except for personnel carriers, rubber-tired, self-propelled electric haulage equipment used in the active workings of underground coal mines shall be equipped with automatic emergency-parking brakes in accordance with the following schedule.
(1) On and after May 23, 1989--
(i) All new equipment ordered; and
(ii) All equipment originally furnished with or retrofitted with automatic emergency-parking brakes which meet the requirements of this section.
(2) On and after May 23, 1991, all other equipment.
(b) Automatic emergency-parking brakes shall--
(1) Be activated immediately by the emergency deenergization device required by 30 CFR 75.523-1 and 75.523-2;
(2) Engage automatically within 5.0 seconds when the equipment is deenergized;
(3) Safely bring the equipment when fully loaded to a complete stop on the maximum grade on which it is operated;
(4) Hold the equipment stationary despite any contraction of brake parts, exhaustion of any non-mechanical source of energy, or leakage; and
(5) Release only by a manual control that does not operate any other equipment function.
(c) Automatic emergency-parking brakes shall include a means in the equipment operator's compartment to--
(1) Apply the brakes manually without deenergizing the equipment; and
(2) Release and reengage the brakes without energizing the equipment.
(d) On and after November 24, 1989, rubber-tired, self-propelled electric face equipment not covered by paragraph (a) of this section shall be equipped with a means incorporated on the equipment and operable from each tramming station to hold the equipment stationary--
(1) On the maximum grade on which it is operated; and
(2) Despite any contraction of components, exhaustion of any non-mechanical source of energy, or leakage.
(e) The brake systems required by paragraphs (a) or (d) of this section shall be applied when the equipment operator is not at the controls of the equipment, except during movement of disabled equip- ment.
The maximum level of alternating or direct electric current that exists between the frames of any two units of electric face equipment that come in contact with each other in the working places of a coal mine, or between the frames of any two units of electric equipment that come in contact with each other in return air outby the last open crosscut, shall not exceed one ampere as determined from the voltage measured across a 0.1 ohm resistor connected between the frames of such equipment.
Appendix A--List of Permissible Electric Face Equipment Approved by the Bureau of Mines Prior to May 23, 1936
| Motor-Driven Mine Equipment | ||
| (Approved Under Schedules 2, 2A, 2B, and 2C) | ||
| Approval No. Date | ||
| AIR COMPRESSORS | ||
| 128 | March 21, 1927. | |
| 128A | July 16, 1926. | |
| COAL DRILLS AND DRILLING MACHINES | ||
| Hand Drills | ||
| 109 | September 19, 1922. | |
| 154 | August 1, 1928. | |
| 184 | February 7, 1930. | |
| 227 | July 29, 1931. | |
| 254 | July 15, 1933. | |
| Post Drills | ||
| 119 | April 15, 1925. | |
| 119A | Do. | |
| 225 | July 10, 1931. | |
| 225A | Do. | |
| 228 | August 12, 1931. | |
| 228A | February 17, 1932. | |
| 230 | August 20, 1931. | |
| 230A | Do. | |
| 237 | December 1, 1931. | |
| 237A | Do. | |
| Drilling Machines | ||
| 147 | February 8, 1928. | |
| 147A | Do. | |
| 176 | September 9, 1929. | |
| 176A | Do. | |
|
LOADING AND CONVEYING EQUIPMENT
LOADING MACHINES
|
||
| Unmounted Type | ||
| 122 | January 8, 1926. | |
| 122A | Do. | |
| Caterpillar-Mounted Type | ||
| 150 | May 11, 1928. | |
| 186 | March 15, 1930. | |
| 222 | May 8, 1931. | |
| 222A | July 28, 1931. | |
| 229 | August 17, 1931. | |
| 229A | Do. | |
| 235 | November 27, 1931. | |
| 235A | October 29, 1931. | |
| 278 | January 17, 1935. | |
| 278A | Do. | |
| 283A | March 12, 1935. | |
| 284A | Do. | |
| 285A | Do. | |
| 294 | September 18, 1935. | |
| 300A | May 6, 1936. | |
| 127 | July 16, 1926. | |
| 127A | September 23, 1927. | |
| Track-Mounted Type | ||
| 194 | June 6, 1930. | |
| 194A | Do. | |
| 217 | February 27, 1931. | |
| 217A | Do. | |
| 276 | January 11, 1935. | |
| 277 | January 17, 1935. | |
| 282A | March 12, 1935. | |
| 291A | July 3, 1935. | |
| Pit-Car Loaders | ||
| 167 | March 27, 1929. | |
| 167A | Do. | |
| 175 | July 26, 1929. | |
| 175A | June 24, 1929. | |
| 250 | December 10, 1932. | |
| 250A | Do. | |
| 252A | February 20, 1933. | |
| CONVEYORS | ||
| Belt Type | ||
| 236 | November 19, 1931. | |
| 287A | March 12, 1935. | |
| 296A | January 6, 1936. | |
| Chain Type | ||
| 151 | May 19, 1928. | |
| 209 | December 2, 1930. | |
| 240 | March 12, 1932. | |
| 240A | Do. | |
| 298A | March 3, 1936. | |
| Power Units for Conveyors | ||
| 265 | February 12, 1934. | |
| 265A | March 19, 1934. | |
| 390A | March 23, 1934. | |
| Shaker Type | ||
| 247 | October 21, 1932. | |
| 257A | August 11, 1933. | |
| 262A | December 8, 1933. | |
| 271 | May 20, 1935. | |
| 271A | October 17, 1934. | |
| 274A | December 13, 1934. | |
| 286A | March 12, 1935. | |
| 295 | September 20, 1935. | |
| 299A | April 9, 1936. | |
| Scraper-type Loaders | ||
| 138 | August 5, 1927. | |
| 138A | Do. | |
| 196 | September 29, 1930. | |
| 196A | July 26, 1930. | |
| 226 | July 27, 1931. | |
| 255 | July 31, 1933. | |
| 256 | Do. | |
|
MINING MACHINES, MACHINERY-MOVING EQUIPMENT,
MISCELLANEOUS TRUCKS, AND WATER SPRAY SUPPLY UNITS
|
||
|
MINING MACHINES |
||
| Shortwall Machines | ||
| 103 | November 2, 1917. | |
| 103A | February 9, 1922. | |
| 105 | Do. | |
| 105A | Do. | |
| 106 | Do. | |
| 106A | Do. | |
| 107 | Do. | |
| 107A | Do. | |
| 108 | Do. | |
| 108A | Do. | |
| 111 | October 16, 1922. | |
| 111A | Do. | |
| 113 | November 4, 1924. | |
| 113A | Do. | |
| 114 | February 7, 1925. | |
| 114A | Do. | |
| 115 | Do. | |
| 115A | Do. | |
| 153 | July 31, 1928. | |
| 153A | Do. | |
| 193 | June 3, 1930. | |
| 193A | Do. | |
| 197 | July 31, 1930. | |
| 197A | Do. | |
| 198 | August 1, 1930. | |
| 198A | Do. | |
| 201 | September 8, 1930. | |
| 201A | Do. | |
| 204 | October 13, 1930. | |
| 204A | December 13, 1930. | |
| 223 | May 13, 1931. | |
| 223A | Do. | |
| 241 | March 18, 1932. | |
| 241A | Do. | |
| 258 | August 15, 1933. | |
| 259A | August 16, 1933. | |
| 260A | August 17, 1933. | |
| 273 | November 30, 1934. | |
| 288 | March 27, 1935. | |
| 288A | Do. | |
| 292 | September 11, 1935. | |
| 292A | Do. | |
| 293A | Do. | |
| Longwall Machines | ||
| 185 | February 24, 1930. | |
| 185A | Do. | |
| 218 | March 10, 1931. | |
| 218A | Do. | |
| 246 | August 19, 1932. | |
| 246A | Do. | |
| 261 | September 12, 1933. | |
| Track or caterpillar mounted | ||
| 112 | March 13, 1924. | |
| 112A | Do. | |
| 118 | March 12, 1925. | |
| 118A | Do. | |
| 125 | April 26, 1926. | |
| 125A | Do. | |
| 172 | April 30, 1929. | |
| 172A | Do. | |
| 188 | April 15, 1930. | |
| 188A | Do. | |
| 207 | November 14, 1930. | |
| 207A | Do. | |
| 216 | February 12, 1931. | |
| 216A | Do. | |
| 231 | August 31, 1931. | |
| 231A | Do. | |
| 242 | April 7, 1932. | |
| 244 | June 18, 1932. | |
| 244A | September 20, 1932. | |
| 253A | February 25, 1933. | |
| 267 | June 27, 1934. | |
| 268A | July 25, 1934. | |
| 269A | September 24, 1934. | |
| 280A | March 4, 1935. | |
| 297 | January 27, 1936. | |
| 297A | Do. | |
| Mine Pumps | ||
| 140 | November 1, 1927. | |
| 140A | Do. | |
| 143 | Do. | |
| 143A | Do. | |
| 144 | Do. | |
| 144A | Do. | |
| 199 | August 18, 1930. | |
| 199A | Do. | |
| 208 | November 29, 1930. | |
| 210 | December 15, 1930. | |
| 210A | Do. | |
| 211 | December 17, 1930. | |
| 211A | Do. | |
| 213 | December 29, 1930. | |
| 213A | Do. | |
| 214 | January 2, 1931. | |
| 214A | Do. | |
| 215 | Do. | |
| 215A | Do. | |
| 248 | October 31, 1932. | |
| 248A | November 23, 1932. | |
| 264 | January 31, 1934. | |
| 264A | Do. | |
| 272 | October 23, 1934. | |
| 272A | Do. | |
| Rock-Dusting Machines | ||
| 130 | November 5, 1926. | |
| 137 | July 2, 1927. | |
| 146 | January 20, 1928. | |
| 146A | April 3, 1928. | |
| 180 | October 30, 1929. | |
| 180A | January 17, 1930. | |
| 206 | November 12, 1930. | |
| 279 | February 14, 1935. | |
| Room and Car-Spotting Hoists | ||
| 116 | February 13, 1925. | |
| 116A | Do. | |
| 164 | January 21, 1931. | |
| 164A | Do. | |
| 165 | Do. | |
| 165A | Do. | |
| 169 | April 5, 1929. | |
| 169A | February 26, 1934 | |
| 190 | April 20, 1930. | |
| 251A | January 16, 1933. | |
| 263 | January 11, 1934. | |
| 266A | February 27, 1934 | |
|
STORAGE-BATTERY LOCOMOTIVES AND POWER TRUCKS
|
|
|
|
|
(Approved under Schedules 15, 2C, 2D, and 2E)
|
|
| Gathering Locomotives | ||
| 1501 | October 11, 1921 | |
| 1502 | November 13, 1922 | |
| 1503 | March 24, 1923. | |
| 1505 | April 5, 1924. | |
| 1507 | August 20, 1925. | |
| 1508 | March 21, 1925. | |
| 1509 | September 25, 1925 | |
| 1511 | November 10, 1925 | |
| 1512 | November 11, 1925. | |
| 1513 | February 25, 1926. | |
| 1516 | December 28, 1926 | |
| 1517 | February 10, 1927. | |
| 1520 | May 27, 1929. | |
| 1521 | June 13, 1930. | |
| 1522 | September 12, 1930 | |
| 1523 | December 19, 1930. | |
| 1525 | July 25, 1934. | |
| 1526 | December 20, 1935. | |
| Tandem Locomotive | ||
| 1518 | November 21, 1927. | |
| Power Trucks | ||
| 1506 | May 5, 1924. | |
| 1505A | June 21, 1926. | |
| 1510C | December 31, 1926. | |
| 1514 | December 18, 1926. | |
| 1515 | December 28, 1926. | |
| 1512C | September 13, 1928. | |
| 1519C | April 6, 1929. | |
| 1524C | June 25, 1934. | |
|
|
JUNCTION, DISTRIBUTION, AND SPLICE BOXES
(Approved under Schedules 2D and 2E)
|
|
| Junction Boxes | ||
| 400 | June 16, 1928. | |
| 400A | August 5, 1925. | |
| 401 | May 11, 1927. | |
| 401A | Do. | |
| 402 | Do. | |
| 402A | Do. | |
| 403 | April 14, 1931. | |
| 403A | Do. | |
| 405A | December 4, 1933. | |
.
.
Subpart G--Trailing Cables
S 75.600 Trailing cables; flame resistance.
[Statutory Provisions]
Trailing cables used in coal mines shall meet the requirements established by the Secretary for flame-resistant cables.
S 75.600-1 Approved cables; flame resistance.
Cables shall be accepted or approved by MSHA as flame resistant.
S 75.601 Short circuit protection of trailing cables.
[Statutory Provisions]
Short circuit protection for trailing cables shall be provided by an automatic circuit breaker or other no less effective device approved by the Secretary of adequate current-interrupting capacity in each ungrounded conductor. Disconnecting devices used to disconnect power from trailing cables shall be plainly marked and identified and such devices shall be equipped or designed in such a manner that it can be determined by visual observation that the power is disconnected.
S 75.601-1 Short circuit protection; ratings and settings of circuit breakers.
Circuit breakers providing short circuit protection for trailing cables shall be set so as not to exceed the maximum allowable instantaneous settings specified in this section; however, higher settings may be permitted by an authorized representative of the Secretary when he has determined that special applications are justified:
|
Conductor size
AWG or MGM
|
Maximum allowable
circuit breaker
instantaneous
setting (amperes)
|
| 14 | 50 |
| 12 | 75 |
| 10 | 150 |
| 8 | 200 |
| 6 | 300 |
| 4 | 500 |
| 3 | 600 |
| 2 | 800 |
| 1 | 1,000 |
| 1/0 | 1,250 |
| 2/0 | 1,500 |
| 3/0 | 2,000 |
| 4/0 | 2,500 |
| 250 | 2,500 |
| 300 | 2,500 |
| 350 | 2,500 |
| 400 | 2,500 |
| 450 | 2,500 |
| 500 | 2,500 |
S 75.601-2 Short circuit protection; use of fuses; approval by the Secretary.
Fuses shall not be employed to provide short circuit protection for trailing cables unless specifi- cally approved by the Secretary.
S 75.601-3 Short circuit protection; dual element fuses; current ratings; maximum values.
Dual element fuses having adequate current-interrupting capacity shall meet the requirements for short circuit protection of trailing cables as provided in S 75.601, however, the current ratings of such devices shall not exceed the maximum values specified in this section:
|
Conductor size
(AWG or MGM)
|
Single conductor
cable
Ampacity Max. fuse rating
|
Two conductor
cable
Ampacity Max. fuse
rating
|
| 14 | 15 15 | |
| 12 | 20 20 | |
| 10 | 25 25 | |
| 8 | 60 60 | 50 50 |
| 6 | 85 90 | 65 70 |
| 4 | 110 110 | 90 90 |
| 3 | 130 150 | 105 110 |
| 2 | 150 150 | 120 125 |
| 1 | 170 175 | 140 150 |
| 1/0 | 200 200 | 170 175 |
| 2/0 | 235 250 | 195 200 |
| 3/0 | 275 300 | 225 225 |
| 4/0 | 315 350 | 260 300 |
| 250 | 350 350 | 285 300 |
| 300 | 395 400 | 310 350 |
| 350 | 445 450 | 335 350 |
| 400 | 480 500 | 360 400 |
| 450 | 515 600 | 385 400 |
| 500 | 545 600 | 415 450 |
S 75.602 Trailing cable junctions.
[Statutory Provision]
When two or more trailing cables junction to the same distribution center, means shall be pro- vided to assure against connecting a trailing cable to the wrong size circuit breaker.
S 75.603 Temporary splice of trailing cable.
[Statutory Provision]
One temporary splice may be made in any trailing cable. Such trailing cable may only be used for the next 24-hour period. No temporary splice shall be made in a trailing cable within 25 feet of the machine, except cable reel equipment. Temporary splices in trailing cables shall be made in a workman- like manner and shall be mechanically strong and well insulated. Trailing cables or hand cables which have exposed wires or which have splices that heat or spark under load shall not be used. As used in this section, the term "splice" means the mechanical joining of one or more conductors that have been severed.
S 75.604 Permanent splicing of trailing cables.
[Statutory Provisions]
When permanent splices in trailing cables are made, they shall be--
(a) Mechanically strong with adequate electrical conductivity and flexibility;
(b) Effectively insulated and sealed so as to exclude moisture; and
(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.
(d) Made using splice kits accepted or approved by MSHA as flame resistant.
S 75.605 Clamping of trailing cables to equipment.
[Statutory Provisions]
Trailing cables shall be clamped to machines in a manner to protect the cables from damage and to prevent strain on the electrical connections.
S 75.606 Protection of trailing cables.
[Statutory Provisions]
Trailing cables shall be adequately protected to prevent damage by mobile equipment.
S 75.607 Breaking trailing cable and power cable connections.
[Statutory Provisions]
Trailing cable and power cable connections to junction boxes shall not be made or broken under load.
Subpart H--Grounding
S 75.700 Grounding metallic sheaths, armors, and conduits enclosing power conductors.
[Statutory Provisions]
All metallic sheaths, armors, and conduits enclosing power conductors shall be electrically continuous throughout and shall be grounded by methods approved by an authorized representative of the Secretary.
S 75.700-1 Approved methods of grounding.
Metallic sheaths, armors and conduits in resistance grounded systems where the enclosed con- ductors are a part of the system will be approved if a solid connection is made to the neutral conductor; in all other systems, the following methods of grounding will be approved:
(a) A solid connection to a borehole casing having low resistance to earth;
(b) A solid connection to metal waterlines having low resistance to earth;
(c) A solid connection to a grounding conductor, other than the neutral conductor of a resistance grounded system, extending to a low resistance ground field located on the surface;
(d) Any other method of grounding, approved by an authorized representative of the Secretary, which ensures that there is no difference in potential between such metallic enclosures and the earth.
S 75.701 Grounding metallic frames, casings, and other enclosures of electric equipment.
[Statutory Provisions]
Metallic frames, casings, and other enclosures of electric equipment that can become "alive" through failure of insulation or by contact with energized parts shall be grounded by methods approved by an authorized representative of the Secretary.
S 75.701-1 Approved methods of grounding of equipment receiving power from ungrounded alternating current power systems.
For purposes of grounding metallic frames, casings and other enclosures of equipment receiving power from ungrounded alternating current power systems, the following methods of grounding will be approved:
(a) A solid connection between the metallic frame, casing, or other metal enclosure and the grounded metallic sheath, armor, or conduit enclosing the power conductor feeding the electrical equip- ment enclosed;
(b) A solid connection to a borehole casing having low resistance to earth;
(c) A solid connection to metal waterlines having low resistance to earth;
(d) A solid connection to a grounding conductor extending to a low resistance ground field located on the surface;
(e) Any other method of grounding, approved by an authorized representative of the Secretary, which ensures that there is no difference in potential between such metal enclosures and the earth.
S 75.701-2 Approved method of grounding metallic frames, casings and other enclosures receiving power from single-phase 110-220-volt circuit.
In instances where single-phase 110-220-volt circuits are used to feed electrical equipment, the only method of grounding that will be approved is the connection of all metallic frames, casings and other enclosures of such equipment to a separate grounding conductor which establishes a continuous connection to a grounded center tap of the transformer.
S 75.701-3 Approved methods of grounding metallic frames, casings and other enclosures of electric equipment receiving power from direct current power systems with one polarity grounded.
For the purpose of grounding metallic frames, casings and enclosures of any electric equipment or device-receiving power from a direct-current power system with one polarity grounded, the following methods of grounding will be approved:
(a) A solid connection to the mine track;
(b) A solid connection to the grounded power conductor of the system;
(c) Silicon diode grounding; however, this method shall be employed only when such devices are installed in accordance with the requirements set forth in paragraph (d) of S 75.703-3; and
(d) Any other method, approved by an authorized representative of the Secretary, which insures that there is no difference in potential between such metal enclosures and the earth.
S 75.701-4 Grounding wires; capacity of wires.
Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be approved if:
(a) The cross-sectional area (size) of the grounding wire is at least one-half the cross-sectional area (size) of the power conductor where the power conductor used is No. 6 A.W.G., or larger.
(b) Where the power conductor used is less than No. 6 A.W.G., the cross-sectional area (size) of the grounding wire is equal to the cross-sectional area (size) of the power conductor.
S 75.701-5 Use of grounding connectors.
The attachment of grounding wires to a mine track or other grounded power conductor will be approved if separate clamps, suitable for such purpose, are used and installed to provide a solid connec- tion.
S 75.702 Protection other than grounding.
[Statutory Provisions]
Methods other than grounding which provide no less effective protection may be permitted by the Secretary or his authorized representative.
S 75.702-1 Protection other than grounding; approved by an authorized representative of the Secretary.
Under this subpart no method other than grounding may be used to ensure against a difference in potential between metallic sheaths, armors and conduits, enclosing power conductors and frames, cas- ings and metal enclosures of electric equipment, and the earth, unless approved by an authorized repre- sentative of the Secretary.
S 75.703 Grounding offtrack direct-current machines and the enclosures of related detached components.
[Statutory Provisions]
The frames of all offtrack direct-current machines and the enclosures of related detached compo- nents shall be effectively grounded, or otherwise maintained at no less safe voltages, by methods ap- proved by an authorized representative of the Secretary.
S 75.703-1 Approved method of grounding.
In instances where the metal frames both of an offtrack direct-current machine and of the metal frames of its component parts are grounded to the same grounding medium the requirements of S 75.703 will be met.
S 75.703-2 Approved grounding mediums.
For purposes of grounding offtrack direct-current machines, the following grounding mediums are approved:
(a) The grounded polarity of the direct-current power system feeding such machines; or,
(b) The alternating current grounding medium where such machines are fed by an ungrounded direct-current power system originating in a portable rectifier receiving its power from a section power center. However, when such a medium is used, a separate grounding conductor must be employed.
S 75.703-3 Approved methods of grounding offtrack mobile, portable and stationary direct-current machines.
In grounding offtrack direct-current machines and the enclosures of their component parts, the following methods of grounding will meet the requirements of S 75.703:
(a) The use of a separate grounding conductor located within the trailing cable of mobile and portable equipment and connected between such equipment and the direct-current grounding medium;
(b) The use of a separate ground conductor located within the direct-current power cable feeding stationary equipment and connected between such stationary equipment and the direct-current grounding medium;
(c) The use of a separate external ground conductor connected between stationary equipment and the direct-current grounding medium; or,
(d) The use of silicon diodes; however, the installation of such devices shall meet the following minimum requirements:
(1) Installation of silicon diodes shall be restricted to electric equipment receiving power from a direct-current system with one polarity grounded;
(2) Where such diodes are used on circuits having a nominal voltage rating of 250, they must have a forward current rating of 400 amperes or more, and have a peak inverse voltage rating of 400 or more;
(3) Where such diodes are used on circuits having a nominal voltage rating of 550, they must have a forward current rating of 250 amperes or more, and have a peak inverse voltage rating of 800 or more;
(4) Where fuses approved by the Secretary are used at the outby end of a trailing cable connected to electrical equipment employing silicon diodes, the rating of such fuses must not exceed 150 percent of the nominal current rating of the grounding diodes;
(5) Where circuit breakers are used at the outby end of a trailing cable connected to electrical equipment employing silicon diodes, the instantaneous trip setting shall not exceed 300 percent of the nominal current rating of the grounding diode;
(6) Overcurrent devices must be used and installed in such a manner that the operating coil circuit of the main contactor will open when a fault current with a value of 25 percent or less of the diode rating flows through the diode;
(7) The silicon diode installed must be suitable to the grounded polarity of the power system in which it is used and its threaded base must be solidly connected to the machine frame on which it is installed;
(8) In addition to the grounding diode, a polarizing diode must be installed in the machine con- trol circuit to prevent operation of the machine when the polarity of a trailing cable is reversed;
(9) When installed on permissible equipment, all grounding diodes, overcurrent devices, and polarizing diodes must be placed in explosion proof compartments;
(10) When grounding diodes are installed on a continuous miner, their nominal diode current rating must be at least 750 amperes or more; and,
(11) All grounding diodes shall be tested, examined and maintained as electrical equipment in accordance with the provisions of S 75.512.
S 75.703-4 Other methods of protecting offtrack direct-current equipment; approved by an autho- rized representative of the Secretary.
Other methods of maintaining safe voltage by preventing a difference between the frames of offtrack direct-current machines and the earth must be approved by an authorized representative of the Secretary.
S 75.704 Grounding frames of stationary high voltage equipment receiving power from un- grounded delta systems.
[Statutory Provisions]
The frames of all stationary high-voltage equipment receiving power from ungrounded delta systems shall be grounded by methods approved by an authorized representative of the Secretary.
S 75.704-1 Approved methods of grounding.
The methods of grounding stated in S 75.701-1 will also be approved with respect to the ground- ing of frames of high-voltage equipment referred to in S 75.704.
S 75.705 Work on high-voltage lines; deenergizing and grounding.
S 75.705-1 Work on high-voltage lines.
(a) Section 75.705 specifically prohibits work on energized high-voltage lines underground;
(b) No high-voltage line, either on the surface or underground, shall be regarded as deenergized for the purpose of performing work on it, until it has been determined by a qualified person (as provided in S 75.153) that such high-voltage line has been deenergized and grounded. Such qualified person shall by visual observation (1) determine that the disconnecting devices on the high-voltage circuit are in open position and (2) ensure that each ungrounded conductor of the high-voltage circuit upon which work is to be done is properly connected to the system-grounding medium. In the case of resistance grounded or solid wye-connected systems, the neutral wire is the system-grounding medium. In the case of an un- grounded power system, either the steel armor or conduit enclosing the system or a surface grounding field is a system grounding medium;
(c) No work shall be performed on any high-voltage line on the surface which is supported by any pole or structure which also supports other high-voltage lines until: (1) All lines supported on the pole or structure are deenergized and grounded in accordance with all of the provisions of this section which apply to the repair of energized surface high-voltage lines; or (2) the provisions of SS 75.705-2 through 75.705-10 have been complied with, with respect to all lines, which are supported on the pole or structure.
(d) Work may be performed on energized surface high-voltage lines only in accordance with the provisions of SS 75.705-2 through 75.705-10, inclusive.
S 75.705-2 Repairs to energized surface high-voltage lines.
An energized high-voltage surface line may be repaired only when--
(a) The operator has determined that--
(1) Such repairs cannot be scheduled during a period when the power circuit could be properly deenergized and grounded;
(2) Such repairs will be performed on power circuits with a phase-to-phase nominal voltage no greater than 15,000 volts;
(3) Such repairs on circuits with a phase-to-phase nominal voltage of 5,000 volts or more will be performed only with the use of live line tools;
(4) Weather conditions will not interfere with such repairs or expose those persons assigned to such work to an imminent danger; and
(b) The operator has designated a person qualified under the provisions of S 75.154 as the person responsible for carrying out such repairs and such person, in order to ensure protection for himself and other qualified persons assigned to perform such repairs from the hazards of such repair, has prepared and filed with the operator:
(1) A general description of the nature and location of the damage or defect to be repaired;
(2) The general plan to be followed in making such repairs;
(3) A statement that a briefing of all qualified persons assigned to make such repairs was con- ducted informing them of the general plan, their individual assignments, and the dangers inherent in such assignments;
(4) A list of the proper protective equipment and clothing that will be provided; and
(5) Such other information as the person designated by the operator feels necessary to describe properly the means or methods to be employed in such repairs.
S 75.705-3 Work on energized high-voltage surface lines; reporting.
Any operator designating and assigning qualified persons to perform repairs on energized high-voltage surface lines under the provisions of S 75.705-2 shall maintain a record of such repairs.
Such record shall contain a notation of the time, date, location, and general nature of the repairs made, together with a copy of the information filed with the operator by the qualified person designated as responsible for performing such repairs.
S 75.705-4 Simultaneous repairs.
When two or more persons are working on an energized high-voltage surface line simulta- neously, and any one of them is within reach of another, such persons shall not be allowed to work on different phases or on equipment with different potentials.
S 75.705-5 Installation of protective equipment.
Before repair work on energized high-voltage surface lines is begun, protective equipment shall be used to cover all bare conductors, ground wires, guys, telephone lines, and other attachments in proximity to the area of planned repairs. Such protective equipment shall be installed from a safe posi- tion below the conductors or other apparatus being covered. Each rubber protective device employed in the making of repairs shall have a dielectric strength of 20,000 volts, or more.
S 75.705-6 Protective clothing; use and inspection.
All persons performing work on energized high-voltage surface lines shall wear protective rubber gloves, sleeves, and climber guards if climbers are worn. Protective rubber gloves shall not be worn wrong side out or without protective leather gloves. Protective devices worn by a person assigned to perform repairs on high-voltage surface lines shall be worn continuously from the time he leaves the ground until he returns to the ground, and, if such devices are employed for extended periods, such person shall visually inspect the equipment assigned him for defects before each use and, in no case, less than twice each day.
S 75.705-7 Protective equipment; inspection.
Each person shall visually inspect protective equipment and clothing provided him in connection with work on high-voltage surface lines before using such equipment and clothing, and any equipment or clothing containing any defect or damage shall be discarded and replaced with proper protective equipment or clothing prior to the performance of any electrical work on such lines.
S 75.705-8 Protective equipment; testing and storage.
(a) All rubber protective equipment used on work on energized high-voltage surface lines shall be electrically tested by the operator in accordance with ASTM standards, part 28, published February 1968, and such testing shall be conducted in accordance with the following schedule:
(1) Rubber gloves, once each month;
(2) Rubber sleeves, once every 3 months;
(3) Rubber blankets, once every 6 months;
(4) Insulator hoods and line hose, once a year; and
(5) Other electric protective equipment, once a year.
(b) Rubber gloves shall not be stored wrong side out. Blankets shall be rolled when not in use, and line hose and insulator hoods shall be stored in their natural position and shape. S 75.705-9 Operat- ing disconnecting or cutout switches.
Disconnecting or cutout switches on energized high-voltage surface lines shall be operated only with insulated sticks, fuse tongs, or pullers which are adequately insulated and maintained to protect the operator from the voltage to which he is exposed. When such switches are operated from the ground, the person operating such devices shall wear protective rubber gloves.
S 75.705-10 Tying into energized high-voltage surface circuits.
If the work of forming an additional circuit by tying into an energized high-voltage surface line is performed from the ground, any person performing such work must wear and employ all of the protec- tive equipment and clothing required under the provisions of SS 75.705-5 and 75.705-6. In addition, the insulated stick used by such person must have been designed for such purpose and must be adequately insulated and be maintained to protect such person from the voltage to which he is exposed.
S 75.705-11 Use of grounded messenger wires; ungrounded systems.
Solely for purposes of grounding ungrounded high-voltage power systems, grounded messenger wires used to suspend the cables of such systems may be used as a grounding medium.
S 75.706 Deenergized underground power circuits; idle days-idle shifts.
[Statutory Provisions]
When not in use, power circuits underground shall be deenergized on idle days and idle shifts, except that rectifiers and transformers may remain energized.
Subpart I--Underground High-Voltage Distribution
S 75.800 High-voltage circuits; circuit breakers.
[Statutory Provisions]
High-voltage circuits entering the underground area of any coal mine shall be protected by suitable circuit breakers of adequate interrupting capacity which are properly tested and maintained as prescribed by the Secretary. Such breakers shall be equipped with devices to provide protection against under-voltage grounded phase, short circuit, and overcurrent.
S 75.800-1 Circuit breakers; location.
Circuit breakers protecting high-voltage circuits entering an underground area of any coal mine shall be located on the surface and in no case installed either underground or within a drift.
S 75.800-2 Approved circuit schemes.
The following circuit schemes will be regarded as providing the necessary protection to the circuits required by S 75.800:
(a) Ground check relays may be used for undervoltage protection if the relay coils are designed to trip the circuit breaker when line voltage decreases to 40 percent to 60 percent of the nominal line voltage;
(b) Ground trip relays on resistance grounded systems will be acceptable as grounded phase protection;
(c) One circuit breaker may be used to protect two or more branch circuits, if the circuit breaker is adjusted to afford overcurrent protection for the smallest conductor.
S 75.800-3 Testing, examination and maintenance of circuit breakers; procedures.
(a) Circuit breakers and their auxiliary devices protecting underground high-voltage circuits shall be tested and examined at least once each month by a person qualified as provided in S75.153;
(b) Tests shall include: (1) Breaking continuity of the ground check conductor, where ground check monitoring is used; and
(2) Actuating at least two of the auxiliary protective relays.
(c) Examination shall include visual observation of all components of the circuit breaker and its auxiliary devices, and such repairs or adjustments as are indicated by such tests and examinations shall be carried out immediately.
S 75.800-4 Testing, examination and maintenance of circuit breakers; record.
The operator of any coal mine shall maintain a written record of each test, examination, repair, or adjustment of all circuit breakers protecting high voltage circuits which enter any underground area of the coal mine. Such record shall be kept in a book approved by the Secretary.
S 75.801 Grounding resistors.
[Statutory Provisions]
The grounding resistor, where required, shall be of the proper ohmic value to limit the voltage drop in the grounding circuit external to the resistor to not more than 100 volts under fault conditions.
The grounding resistor shall be rated for maximum fault current continuously and insulated from ground for a voltage equal to the phase-to-phase voltage of the system.
(a) Except as provided in paragraph (b) of this section, high-voltage circuits extending under- ground and supplying portable, mobile, or, stationary high-voltage equipment shall contain either a direct or derived neutral which shall be grounded through a suitable resistor at the source transformers, and a grounding circuit, originating at the grounded side of the grounding resistor, shall extend along with the power conductors and serve as a grounding conductor for the frames of all high-voltage equipment supplied power from that circuit.
(b) Notwithstanding the requirements of paragraph (a) of this section, the Secretary or his autho- rized representative may permit ungrounded high-voltage circuits to be extended underground to feed stationary electric equipment if--
(1) Such circuits are either steel armored or installed in grounded, rigid steel conduit throughout their entire length; or,
(2) The voltage of such circuits is nominally 2,400 volts or less phase-to-phase and the cables used in such circuits are equipped with metallic shields around each power conductor, and contain one or more ground conductors having a total cross sectional area of not less than one-half the power conduc- tor; and,
(3) Upon a finding by the Secretary or his authorized representative that the use of the circuits described in paragraphs (b)(1) and (2) of this section does not pose a hazard to the miners.
(c) Within 100 feet of the point on the surface where high-voltage circuits enter the underground portion of the mine, disconnecting devices shall be installed and so equipped or designed in such a manner that it can be determined by visual observation that the power is disconnected, except that the Secretary or his authorized representative may permit such devices to be installed at a greater distance from such area of the mine if he determines, based on existing physical conditions, that such installation will be more accessible at a greater distance and will not pose any hazard to the miners.
S 75.803 Fail safe ground check circuits on high-voltage resistance grounded systems.
[Statutory Provisions]
On and after September 30, 1970, high-voltage, resistance grounded systems shall include a fail safe ground check circuit to monitor continuously the grounding circuit to assure continuity and the fail safe ground check circuit shall cause the circuit breaker to open when either the ground or pilot check wire is broken, or other no less effective device approved by the Secretary or his authorized representa- tive to assure such continuity, except that an extension of time, not in excess of 12 months, may be permitted by the Secretary on a mine-by-mine basis if he determines that such equipment is not avail- able.
S 75.803-1 Maximum voltage ground check circuits.
The maximum voltage used for ground check circuits under S75.803 shall not exceed 96 volts.
S 75.803-2 Ground check systems not employing pilot check wires; approval by the Secretary.
Ground check systems not employing pilot check wires will be approved only if it is determined that the system includes a fail safe design causing the circuit breaker to open when ground continuity is broken.
S 75.804 Underground high-voltage cables.
(a) Underground high-voltage cables used in resistance grounded systems shall be equipped with metallic shields around each power conductor with one or more ground conductors having a total cross sectional area of not less than one-half the power conductor, and with an insulated external conductor not smaller than No. 8 (A.W.G.) or an insulated internal ground check conductor not smaller than No. 10 (A.W.G.) for the ground continuity check circuit.
(b) All such cables shall be adequate for the intended current and voltage. Splices made in such cables shall provide continuity of all components.
S 75.805 Couplers.
[Statutory Provisions]
Couplers that are used with medium-voltage or high-voltage power circuits shall be of the three-phase type with a full metallic shell, except that the Secretary may permit, under such guidelines as he may prescribe, no less effective couplers constructed of materials other than metal. Couplers shall be adequate for the voltage and current expected. All exposed metal on the metallic couplers shall be grounded to the ground conductor in the cable. The coupler shall be constructed so that the ground check continuity conductor shall be broken first and the ground conductors shall be broken last when the coupler is being uncoupled.
S 75.806 Connection of single-phase loads.
[Statutory Provisions]
Single-phase loads, such as transformer primaries, shall be connected phase-to-phase.
S 75.807 Installation of high-voltage transmission cables.
[Statutory Provisions]
All underground high-voltage transmission cables shall be installed only in regularly inspected air courses and haulageways, and shall be covered, buried, or placed so as to afford protection against damage, guarded where men regularly work or pass under them unless they are 6 1/2 feet or more above the floor or rail, securely anchored, properly insulated, and guarded at ends, and covered, insulated, or placed to prevent contact with trolley wires and other low-voltage circuits.
S 75.808 Disconnecting devices.
[Statutory Provisions]
Disconnecting devices shall be installed at the beginning of branch lines in high-voltage circuits and equipped or designed in such a manner that it can be determined by visual observation that the circuit is deenergized when the switches are open.
S 75.809 Identification of circuit breakers and disconnecting switches.
[Statutory Provisions]
Circuit breakers and disconnecting switches underground shall be marked for identification.
S 75.810 High-voltage trailing cables; splices.
[Statutory Provisions]
In the case of high-voltage cables used as trailing cables, temporary splices shall not be used and all permanent splices shall be made in accordance with S 75.604. Terminations and splices in all other high-voltage cables shall be made in accordance with the manufacturer's specifications.
S 75.811 High-voltage underground equipment; grounding.
[Statutory Provisions]
Frames, supporting structures and enclosures of stationary, portable, or mobile underground high-voltage equipment and all high-voltage equipment supplying power to such equipment receiving power from resistance grounded systems shall be effectively grounded to the high-voltage ground.
S 75.812 Movement of high-voltage power centers and portable transformers; permit.
[Statutory Provisions]
Power centers and portable transformers shall be deenergized before they are moved from one location to another, except that, when equipment powered by sources other than such centers or trans- formers is not available, the Secretary may permit such centers and transformers to be moved while energized, if he determines that another equivalent or greater hazard may otherwise be created, and if they are moved under the supervision of a qualified person, and if such centers and transformers are examined prior to such movement by such person and found to be grounded by methods approved by an authorized representative of the Secretary and otherwise protected from hazards to the miner. A record shall be kept of such examinations. High-voltage cables, other than trailing cables, shall not be moved or handled at any time while energized, except that, when such centers and transformers are moved while energized as permitted under this section, energized high-voltage cables attached to such centers and transformers may be moved only by a qualified person and the operator of such mine shall require that such person wear approved and tested insulated wireman's gloves.
S 75.812-1 Qualified person.
A person who meets the requirements of S 75.153 is a qualified person within the meaning of S 75.812.
S 75.812-2 High-voltage power centers and transformers; record of examination.
The operator shall maintain a record of all examinations conducted in accordance with S 75.812.
Such record shall be kept in a book approved by the Secretary.
Subpart J--Underground Low- and Medium-Voltage Alternating Current Circuits
S 75.900 Low- and medium-voltage circuits serving three-phase alternating current equipment; circuit breakers.
[Statutory Provisions]
Low- and medium-voltage power circuits serving three-phase alternating current equipment shall be protected by suitable circuit breakers of adequate interrupting capacity which are properly tested and maintained as prescribed by the Secretary. Such breakers shall be equipped with devices to provide protection against undervoltage, grounded phase, short circuit, and overcurrent.
S 75.900-1 Circuit breakers; location.
Circuit breakers used to protect low-and medium-voltage circuits underground shall be located in areas which are accessible for inspection, examination, and testing, have safe roofs, and are clear of any moving equipment used in haulageways.
S 75.900-2 Approved circuit schemes.
The following circuit schemes will be regarded as providing the necessary protection to the circuit required by S 75.900:
(a) Ground check relays may be used for undervoltage protection if the relay coils are designed to trip the circuit breaker when line voltage decreases to 40 to 60 percent of the nominal line voltage.
(b) One undervoltage device installed in the main secondary circuit at the source transformer may be used to provide undervoltage protection for each circuit that receives power from that transformer.
(c) One circuit breaker may be used to protect two or more branch circuits if the circuit breaker is adjusted to afford overcurrent protection for the smallest conductor.
(d) Circuit breakers with shunt trip, series trip or undervoltage release devices may be used if the tripping elements of such devices are selected or adjusted in accordance with the settings listed in the tables of the National Electric Code, 1968.
S 75.900-3 Testing, examination, and maintenance of circuit breakers; procedures.
Circuit breakers protecting low- and medium-voltage alternating current circuits serving three-phase alternating current equipment and their auxiliary devices shall be tested and examined at least once each month by a person qualified as provided in S 75.153. In performing such tests, actuating any of the circuit breaker auxiliaries or control circuits in any manner which causes the circuit breaker to open, shall be considered a proper test. All components of the circuit breaker and its auxiliary devices shall be visually examined and such repairs or adjustments as are indicated by such tests and examina- tions shall be carried out immediately.
S 75.900-4 Testing, examination, and maintenance of circuit breakers; record.
The operator of any coal mine shall maintain a written record of each test, examination, repair, or adjustment of all circuit breakers protecting low- and medium-voltage circuits serving three-phase alternating current equipment used in the mine. Such record shall be kept in a book approved by the Secretary.
S 75.901 Protection of low- and medium-voltage three-phase circuits used underground.
[Statutory Provisions]
(a) Low- and medium-voltage three-phase alternating-current circuits used underground shall contain either a direct or derived neutral which shall be grounded through a suitable resistor at the power center, and a grounding circuit, originating at the grounded side of the grounding resistor, shall extend along with the power conductors and serve as a grounding conductor for the frames of all the electrical equipment supplied power from that circuit, except that the Secretary or his authorized representative may permit ungrounded low- and medium-voltage circuits to be used underground to feed such station- ary electrical equipment if such circuits are either steel armored or installed in grounded rigid steel conduit throughout their entire length. The grounding resistor, where required, shall be of the proper ohmic value to limit the ground fault current to 25 amperes. The grounding resistor shall be rated for maximum fault current continuously and insulated from ground for a voltage equal to the phase-to-phase voltage of the system.
S 75.902 Low- and medium-voltage ground check monitor circuits.
[Statutory Provisions]
On or before September 30, 1970, low- and medium-voltage resistance grounded systems shall include a fail-safe ground check circuit to monitor continuously the grounding circuit to assure continu- ity which ground check circuit shall cause the circuit breaker to open when either the ground or pilot check wire is broken, or other no less effective device approved by the Secretary or his authorized representative to assure such continuity, except that an extension of time, not in excess of 12 months, may be permitted by the Secretary on a mine-by-mine basis if he determines that such equipment is not available. Cable couplers shall be constructed so that the ground check continuity conductor shall be broken first and the ground conductors shall be broken last when the coupler is being uncoupled.
S 75.902-1 Maximum voltage ground check circuits.
The maximum voltage used for such ground check circuits shall not exceed 40 volts.
S 75.902-2 Approved ground check systems not employing pilot check wires.
Ground check systems not employing pilot check wires will be approved only if it is determined that the system includes a fail safe design causing the circuit breaker to open when ground continuity is broken.
S 75.902-4 Attachment of ground conductors and ground check wires to equipment frames; use of separate connections.
In grounding equipment frames of all stationary, portable or mobile equipment receiving power from resistance grounded systems separate connections shall be used when practicable.
S 75.903 Disconnecting devices.
[Statutory Provisions]
Disconnecting devices shall be installed in conjunction with the circuit breaker to provide visual evidence that the power is disconnected.
S 75.904 Identification of circuit breakers.
[Statutory Provisions]
Circuit breakers shall be marked for identification.
S 75.905 Connection of single-phase loads.
[Statutory Provisions]
Single-phase loads shall be connected phase-to-phase.
S 75.906 Trailing cables for mobile equipment, ground wires, and ground check wires.
S 75.907 Design of trailing cables for medium-voltage circuits.
[Statutory Provisions]
Trailing cables for medium-voltage circuits shall include grounding conductors, a ground check conductor, and grounded metallic shields around each power conductor or a ground metallic shield over the assembly, except that on equipment employing cable reels, cables without shields may be used if the insulation is rated 2,000 volts or more.
Subpart K--Trolley Wires and Trolley Feeder Wires
S 75.1000 Cutout switches.
[Statutory Provisions]
Trolley wires and trolley feeder wires, shall be provided with cutout switches at intervals of not more than 2,000 feet and near the beginning of all branch lines.
S 75.1001 Overcurrent protection.
[Statutory Provisions]
Trolley wires and trolley feeder wires shall be provided with overcurrent protection.
S 75.1001-1 Devices for overcurrent protection; testing and calibration requirements; records.
(a) Automatic circuit interrupting devices that will deenergize the affected circuit upon occur- rence of a short circuit at any point in the system will meet the requirements of S 75.1001.
(b) Automatic circuit interrupting devices described in paragraph (a) of this section shall be tested and calibrated at intervals not to exceed six months. Testing of such devices shall include passing the necessary amount of electric current through the device to cause activation. Calibration of such devices shall include adjustment of all associated relays to +/-15 percent of the indicated value. An authorized representative of the Secretary may require additional testing or calibration of these devices.
(c) A record of the tests and calibrations required by paragraph (b) of this section shall be kept, and shall be made available, upon request, to an authorized representative of the Secretary or the State Mine Inspector.
S 75.1002 Location of trolley wires, trolley feeder wires, high-voltage cables and transformers.
[Statutory Provisions]
Trolley wires and trolley feeder wires, high-voltage cables and transformers shall not be located inby the last open crosscut and shall be kept at least 150 feet from pillar workings.
S 75.1002-1 Location of other electric equipment; requirements for permissibility.
(a) Electric equipment other than trolley wires, trolley feeder wires, high-voltage cables, and transformers shall be permissible, and maintained in a permissible condition when such electric equip- ment is located within 150 feet from pillar workings, except as provided in paragraphs (b) and (c) of this section.
(b) Notwithstanding the provisions of paragraph (a) of this section, in any coal mine where nonpermissible electric face equipment may be taken into or used inby the last open crosscut until March 30, 1974, such nonpermissible electric face equipment may be located within 150 feet from pillar work- ings.
(c) Notwithstanding the provisions of paragraph (a) of this section, in any coal mine where a permit for noncompliance is in effect, nonpermissible electric face equipment specified in such permit for noncompliance may be located within 150 feet from pillar workings for the duration of such permit.
S 75.1003 Insulation of trolley wires, trolley feeder wires and bare signal wires; guarding of trolley wires and trolley feeder wires.
[Statutory Provisions]
Trolley wires, trolley feeder wires, and bare signal wires shall be insulated adequately where they pass through doors and stoppings, and where they cross other power wires and cables. Trolley wires and trolley feeder wires shall be guarded adequately:
(a) At all points where men are required to work or pass regularly under the wires;
(b) On both sides of all doors and stoppings; and
(c) At man-trip stations.
The Secretary or his authorized representatives shall specify other conditions where trolley wires and trolley feeder wires shall be adequately protected to prevent contact by any person, or shall require the use of improved methods to prevent such contact. Temporary guards shall be provided where trackmen and other persons work in proximity to trolley wires and trolley feeder wires.
S 75.1003-1 Other requirements for guarding of trolley wires and trolley feeder wires.
Adequate precaution shall be taken to insure that equipment being moved along haulageways will not come in contact with trolley wires or trolley feeder wires.
(a) Prior to moving or transporting any unit of off-track mining equipment in areas of the active workings where energized trolley wires or trolley feeder wires are present:
(1) The unit of equipment shall be examined by a certified person to ensure that coal dust, float coal dust, loose coal oil, grease, and other combustible materials have been cleaned up and have not been permitted to accumulate on such unit of equipment; and,
(2) A qualified person, as specified in S 75.153 of this part, shall examine the trolley wires, trolley feeder wires, and the associated automatic circuit interrupting devices provided for short circuit protection to ensure that proper short circuit protection exists.
(b) A record shall be kept of the examinations required by paragraph (a) of this section, and shall be made available, upon request, to an authorized representative of the Secretary.
(c) Off-track mining equipment shall be moved or transported in areas of the active workings where energized trolley wires or trolley feeder wires are present only under the direct supervision of a certified person who shall be physically present at all times during moving or transporting operations.
(d) The frames of off-track mining equipment being moved or transported, in accordance with this section, shall be covered on the top and on the trolley wire side with fire-resistant material which has met the applicable requirements of part 18 of Subchapter D of this chapter (Bureau of Mines Sched- ule 2G).
(e) Electrical contact shall be maintained between the mine track and the frames of off-track mining equipment being moved in-track and trolley entries, except that rubber-tired equipment need not be grounded to a transporting vehicle if no metal part of such rubber-tired equipment can come into contact with the transporting vehicle.
(f) A minimum vertical clearance of 12 inches shall be maintained between the farthest projec- tion of the unit of equipment which is being moved and the energized trolley wires or trolley feeder wires at all times during the movement or transportation of such equipment; provided, however, that if the height of the coal seam does not permit 12 inches of vertical clearance to be so maintained, the following additional precautions shall be taken:
(1)(i) Except as provided in paragraph (f)(1)(ii) of this section electric power shall be supplied to the trolley wires or trolley feeder wires only from outby the unit of equipment being moved or trans- ported.
(ii) Where direct current electric power is used and such electric power can be supplied only from inby the equipment being moved or transported, power may be supplied from inby such equipment provided a miner with the means to cut off the power, and in direct communication with persons actually engaged in the moving or transporting operation, is stationed outby the equipment being moved.
(2) The settings of automatic circuit interrupting devices used to provide short circuit protection for the trolley circuit shall be reduced to not more than one-half of the maximum current that could flow if the equipment being moved or transported were to come into contact with the trolley wire or trolley feeder wire;
(3) At all times the unit of equipment is being moved or transported, a miner shall be stationed at the first automatic circuit breaker outby the equipment being moved and such miner shall be: (i) In direct communication with persons actually engaged in the moving or transporting operation, and (ii) capable of communicating with the responsible person on the surface required to be on duty in accordance with S 75.1600-1 of this part;
(4) Where trolley phones are utilized to satisfy the requirements of paragraph (f)(3) of this sec- tion, telephones or other equivalent two-way communication devices that can readily be connected with the mine communication system shall be carried by the miner stationed at the first automatic circuit breaker outby the equipment being moved and by a miner actually engaged in the moving or transporting operation; and,
(5) No person shall be permitted to be inby the unit of equipment being moved or transported, in the ventilating current of air that is passing over such equipment, except those persons directly engaged in moving such equipment.
(g) The provisions of paragraphs (a) through (f) of this section shall not apply to units of mining equipment that are transported in mine cars, provided that no part of the equipment extends above or over the sides of the mine car.
Subpart L--Fire Protection
S 75.1100 Requirements.
[Statutory Provision]
Each coal mine shall be provided with suitable firefighting equipment adapted for the size and conditions of the mine. The Secretary shall establish minimum requirements of the type, quality, and quantity of such equipment.
S 75.1100-1 Type and quality of firefighting equipment.
Firefighting equipment required under this subpart shall meet the following minimum require- ments:
(a) Waterlines: Waterlines shall be capable of delivering 50 gallons of water a minute at a nozzle pressure of 50 pounds per square inch.
(b) Portable water cars: A portable water car shall be of at least 1,000 gallons capacity (500 gallons capacity for anthracite mines) and shall have at least 300 feet of fire hose with nozzles. A por- table water car shall be capable of providing a flow through the hose of 50 gallons of water per minute at nozzle pressure of 50 pounds per square inch.
(c) A portable chemical car shall carry enough chemicals to provide a fire extinguishing capacity equivalent to that of a portable water car.
(d) Portable foam-generating machines or devices: A portable foam-generating machine or device shall have facilities and equipment for supplying the machine with 30 gallons of water per minute at 30 pounds per square inch for a period of 35 minutes.
(e) Portable fire extinguisher: A portable fire extinguisher shall be either (1) a multipurpose dry chemical type containing a nominal weight of 5 pounds of dry powder and enough expellant to apply the powder or (2) a foam-producing type containing at least 2 1/2 gallons of foam-producing liquids and enough expellant to supply the foam. Only fire extinguishers approved by the Underwriters Laboratories, Inc., or Factory Mutual Research Corp., carrying appropriate labels as to type and purpose, shall be used.
After March 30, 1971, all new portable fire extinguishers acquired for use in a coal mine shall have a 2A 10 BC or higher rating.
(f)(1) Except as provided in paragraph (f)(2) of this section, the fire hose shall be lined with a material having flame resistant qualities meeting requirements for hose in Bureau of Mines' Schedule 2G. The cover shall be polyester, or other material with flame-spread qualities and mildew resistance equal or superior to polyester. The bursting pressure shall be at least 4 times the water pressure at the valve to the hose inlet with the valve closed; the maximum water pressure in the hose nozzle shall not exceed 100 ps.i.g.
(2) Fire hose installed for use in underground coal mines prior to December 30, 1970, shall be mildew-proof and have a bursting pressure at least 4 times the water pressure at the valve to the hose inlet with the valve closed, and the maximum water pressure in the hose nozzle with water flowing shall not exceed 100 p. s.i.g.
S 75.1100-2 Quantity and location of firefighting equipment.
(a) Working sections. (1) Each working section of coal mines producing 300 tons or more per shift shall be provided with two portable fire extinguishers and 240 pounds of rock dust in bags or other suitable containers; waterlines shall extend to each section loading point and be equipped with enough fire hose to reach each working face unless the section loading point is provided with one of the follow- ing:
(i) Two portable water cars; or
(ii) Two portable chemical cars; or
(iii) One portable water car or one portable chemical car, and either (a) a portable foam-generating machine or (b) a portable high-pressure rock-dusting machine fitted with at least 250 feet of hose and supplied with at least 60 sacks of rock dust.
(2) Each working section of coal mines producing less than 300 tons of coal per shift shall be provided with two portable fire extinguishers, 240 pounds of rock dust in bags or other suitable contain- ers, and at least 500 gallons of water and at least 3 pails of 10 quart capacity. In lieu of the 500 gallon water supply a waterline with sufficient hose to reach the working places, a portable water car (500 gallons capacity) or a portable all-purpose dry powder chemical car of at least 125-pounds capacity may be provided.
(b) Belt conveyors. In all coal mines, waterlines shall be installed parallel to the entire length of belt conveyors and shall be equipped with firehose outlets with valves at 300-foot intervals along each belt conveyor and at tailpieces. At least 500 feet of firehose with fittings suitable for connection with each belt conveyor waterline system shall be stored at strategic locations along the belt conveyor. Water- lines may be installed in entries adjacent to the conveyor entry belt as long as the outlets project into the belt conveyor entry.
(c) Haulage tracks. (1) In mines producing 300 tons of coal or more per shift waterlines shall be installed parallel to all haulage tracks using mechanized equipment in the track or adjacent entry and shall extend to the loading point of each working section. Waterlines shall be equipped with outlet valves at intervals of not more than 500 feet, and 500 feet of firehose with fittings suitable for connec- tion with such waterlines shall be provided at strategic locations. Two portable water cars, readily avail- able, may be used in lieu of waterlines prescribed under this paragraph.
(2) In mines producing less than 300 tons of coal per shift, there shall be provided at 500-foot intervals in all main and secondary haulage roads:
(i) A tank of water of at least 55-gallon capacity with at least 3 pails of not less than 10-quart capacity; or
(ii) Not less than 240 pounds of bagged rock dust.
(d) Transportation. Each track or off-track locomotive, self-propelled man-trip car, or personnel carrier shall be equipped with one portable fire extinguisher.
(e) Electrical installations. (1) Two portable fire extinguishers or one extinguisher having at least twice the minimum capacity specified for a portable fire extinguisher in S 75.1100-1(e) shall be provided at each permanent electrical installation.
(2) One portable fire extinguisher and 240 pounds of rock dust shall be provided at each tempo- rary electrical installation.
(f) Oil storage stations. Two portable fire extinguishers and 240 pounds of rock dust shall be provided at each permanent underground oil storage station. One portable fire extinguisher shall be provided at each working section where 25 gallons or more of oil are stored in addition to extinguishers required under paragraph (a) of this section.
(g) Welding, cutting, soldering. One portable fire extinguisher or 240 pounds of rock dust shall be provided at locations where welding, cutting, or soldering with arc or flame is being done.
(h) Powerlines. At each wooden door through which powerlines pass there shall be one portable fire extinguisher or 240 pounds of rock dust within 25 feet of the door on the intake air side.
(i) Emergency materials. (1) At each mine producing 300 tons of coal or more per shift there shall be readily available the following materials at locations not exceeding 2 miles from each working section:
1,000 board feet of brattice boards
2 rolls of brattice cloth
2 hand saws
25 pounds of 8d nails
25 pounds of 10d nails
25 pounds of 16d nails
3 claw hammers
25 bags of wood fiber plaster or 10 bags of cement (or equivalent material for stoppings)
5 tons of rock dust
(2) At each mine producing less than 300 tons of coal per shift the above materials shall be available at the mine, provided, however, that the emergency materials for one or more mines may be stored at a central warehouse or building supply company and such supply must be the equivalent of that required for all mines involved and within 1-hour's delivery time from each mine. This exception shall not apply where the active working sections are more than 2 miles from the surface.
S 75.1100-3 Condition and examination of firefighting equipment.
All firefighting equipment shall be maintained in a usable and operative condition. Chemical extinguishers shall be examined every 6 months and the date of the examination shall be written on a permanent tag attached to the extinguisher.
S 75.1101 Deluge-type water sprays, foam generators; main and secondary belt-conveyor drives.
[Statutory Provisions]
Deluge-type water sprays or foam generators automatically actuated by rise in temperature, or other no less effective means approved by the Secretary of controlling fire, shall be installed at main and secondary belt-conveyor drives.
S 75.1101-1 Deluge-type water spray systems.
(a) Deluge-type spray systems shall consist of open nozzles attached to branch lines. The branch lines shall be connected to a waterline through a control valve operated by a fire sensor. Actuation of the control valve shall cause water to flow into the branch lines and discharge from the nozzles.
(b) Nozzles attached to the branch lines shall be full cone, corrosion resistant and provided with blow-off dust covers. The spray application rate shall not be less than 0.25 gallon per minute per square foot of the top surface of the top belt and the discharge shall be directed at both the upper and bottom surfaces of the top belt and to the upper surface of the bottom belt.
S 75.1101-2 Installation of deluge-type sprays.
Deluge-type water spray systems shall provide protection for the belt drive and 50 feet of fire-resistant belt or 150 feet of nonfire-resistant belt adjacent to the belt drive.
S 75.1101-3 Water requirements.
Deluge-type water spray systems shall be attached to a water supply. Water so supplied shall be free of excessive sediment and noncorrosive to the system. Water pressure shall be maintained consistent with the pipe, fittings, valves, and nozzles at all times. Water systems shall include strainers with a flush-out connection and a manual shut-off valve. The water supply shall be adequate to provide flow for 10 minutes except that pressure tanks used as a source of water supply shall be of 1,000-gallon capacity for a fire-resistant belt and 3,000 gallons for a nonfire-resistant belt may be provided.
S 75.1101-4 Branch lines.
As a part of the deluge-type water spray system, two or more branch lines of nozzles shall be installed. The maximum distance between nozzles shall not exceed 8 feet.
S 75.1101-5 Installation of foam generator systems.
(a) Foam generator systems shall be located so as to discharge foam to the belt drive, belt takeup, electrical controls, gear reducing unit and the conveyor belt.
(b) Foam generator systems shall be equipped with a fire sensor which actuates the system, and each system shall be capable of producing and delivering the following amounts of foam within 5 min- utes:
(1) At fire-resistant belt installations, an amount which will fully envelop the belt drive, belt takeup, electrical controls, gear reducing unit, and the conveyor belt over a distance of 50 feet; and,
(2) At nonfire-resistant belt installations, an amount which will fully envelop the belt drive, belt takeup electrical controls, gear reducing unit, and the conveyor belt over a distance of 150 feet.
(c) The foam generator shall be equipped with a warning device designed to stop the belt drive when a fire occurs and all such warning devices shall be capable of giving both an audible and visual signal when actuated by fire.
(d) Water, power, and chemicals required shall be adequate to maintain water or foam flow for no less than 25 minutes.
(e) Water systems shall include strainers with a flush-out connection and a manual shut-off valve.
S 75.1101-6 Water sprinkler systems; general.
Water sprinkler systems may be installed to protect main and secondary belt-conveyor drives; however, where such systems are employed, they shall be installed and maintained in accordance with SS 75.1101-7 through 75.1101-11.
S 75.1101-7 Installation of water sprinkler systems; requirements.
(a) The fire-control components of each water sprinkler system shall be installed, as far as practi- cable in accordance with the recommendations set forth in National Fire Protection Association 1968-69 edition, Code No. 13, "Installation of Sprinkler Systems" and such systems' components shall be of a type approved by the Underwriters' Laboratories, Inc., Factory Mutual Research Corp.
(b) Each sprinkler system shall provide protection for the motor drive belt takeup, electrical controls, gear reducing unit, and the 50 feet of fire-resistant belt, or 150 feet of nonfire-resistant belt adjacent to the belt drive.
(c) The components of each water sprinkler system shall be located so as to minimize the possi- bility of damage by roof fall or by the moving belt and its load.
S 75.1101-8 Water sprinkler systems; arrangement of sprinklers.
(a) At least one sprinkler shall be installed above each belt drive, belt take-up, electrical control, and gear-reducing unit, and individual sprinklers shall be installed at intervals of no more than 8 feet along all conveyor branch lines.
(b) Two or more branch lines, at least one of which shall be above the top belt and one between the top and bottom belt, shall be installed in each sprinkler system to provide a uniform discharge of water to the belt surface.
(c) The water discharge rate from the sprinkler system shall not be less than 0.25 gallon per minute per square foot of the top surface of the top belt and the discharge shall be directed at both the upper and bottom surfaces of the top belt and to the upper surface of the bottom belt. The supply of water shall be adequate to provide a constant flow of water for 10 minutes with all sprinklers function- ing.
(d) Each individual sprinkler shall be activated at a temperature of not less than 150 oF. and not more than 300 oF.
(e) Water systems shall include strainers with a flush-out connection and a manual shut-off valve.
S 75.1101-9 Back-up water system.
One fire hose outlet together with a length of hose capable of extending to the belt drive shall be provided within 300 feet of each belt drive.
S 75.1101-10 Water sprinkler systems; fire warning devices at belt drives.
Each water sprinkler system shall be equipped with a device designed to stop the belt drive in the event of a rise in temperature and each such warning device shall be capable of giving both an audible and visual warning when a fire occurs.
S 75.1101-11 Inspection of water sprinkler systems.
Each water sprinkler system shall be examined weekly and a functional test of the complete system shall be conducted at least once each year.
S 75.1101-12 Equivalent dry-pipe system.
Where water sprinkler systems are installed to protect main and secondary belt conveyor drives and freezing temperatures prevail, an equivalent dry-pipe system may be installed.
S 75.1101-13 Dry powder chemical systems; general.
Self-contained dry powder chemical systems may be installed to protect main and secondary belt conveyor drives, however, where such systems are employed, they shall be installed and maintained in accordance with the provisions of SS 75.1101-14 through 75.1101-22.
S 75.1101-14 Installation of dry powder chemical systems.
(a) Self-contained dry powder chemical systems shall be installed to protect each belt-drive, belt takeup, electrical-controls, gear reducing units and 50 feet of fire-resistant belt or 150 feet of non-fire-resistant belt adjacent to the belt drive.
(b) The fire-control components of each dry powder chemical system shall be a type approved by the Underwriters' Laboratories, Inc., or Factory Mutual Engineering Corp.
(c) The components of each dry powder chemical system shall be located so as to minimize the possibility of damage by roof fall or by the moving belt and its load.
S 75.1101-15 Construction of dry powder chemical systems.
(a) Each self-contained dry powder system shall be equipped with hose or pipe lines which are no longer than necessary.
(b) Metal piping and/or hose between control valves and nozzles shall have a minimum bursting pressure of 500 p.s.i.g.
(c) Hose shall be protected by wire braid or its equivalent.
(d) Nozzles and reservoirs shall be sufficient in number to provide maximum protection to each belt, belt takeup, electrical controls, and gear reducing unit.
(e) Each belt shall be protected on the top surface of both the top and bottom belts and the bot- tom surface of the top belt.
S 75.1101-16 Dry powder chemical systems; sensing and fire-suppression devices.
(a) Each self-contained dry powder chemical system shall be equipped with sensing devices which shall be designed to activate the fire-control system, sound an alarm and stop the conveyor drive motor in the event of a rise in temperature, and provision shall be made to minimize contamination of the lens of any optical sensing device installed in such system.
(b) Where sensors are operated from the same power source as the belt drive, each sensor shall be equipped with a standby power source which shall be capable of remaining operative for at least 4 hours after a power cutoff.
(c) Sensor systems shall include a warning indicator (or test circuit) which shows it is operative.
(d) Each fire-suppression system shall be equipped with a manually operated control valve which shall be independent of the sensor.
S 75.1101-17 Sealing of dry powder chemical systems.
Each dry powder chemical system shall be adequately sealed to protect all components of the system from moisture dust, and dirt.
S 75.1101-18 Dry powder requirements.
Each dry powder chemical system shall contain the following minimum amounts of multipurpose dry powder:
S 75.1101-19 Nozzles; flow rate and direction.
The nozzles of each dry powder chemical system shall be capable of discharging all powder within 1 minute after actuation of the system and such nozzles shall be directed so as to minimize the effect of ventilation upon fire control.
S 75.1101-20 Safeguards for dry powder chemical systems.
Adequate guards shall be provided along all belt conveyors in the vicinity of each dry powder chemical system to protect persons whose vision is restricted by a discharge of powder from the system.
In addition, hand-rails shall be installed in such areas to provide assistance to those passing along the conveyor after a powder discharge.
S 75.1101-21 Back-up water system.
One fire hose outlet together with a length of hose capable of extending to the belt drive shall be provided within 300 feet of each belt drive.
S 75.1101-22 Inspection of dry powder chemical systems.
(a) Each dry powder chemical system shall be examined weekly and a functional test of the complete system shall be conducted at least once each year.
(b) Where the dry powder chemical system has been actuated, all components of the system shall be cleaned immediately by flushing all powder from pipes and hoses and all hose damaged by fire shall be replaced.
S 75.1101-23 Program of instruction; location and use of fire fighting equipment; location of escapeways, exits and routes of travel; evacuation procedures; fire drills.
(a) Each operator of an underground coal mine shall adopt a program for the instruction of all miners in the location and use of fire fighting equipment, location of escapeways, exits, and routes of travel to the surface, and proper evacuation procedures to be followed in the event of an emergency.
Such program shall be submitted for approval to the District Manager of the Coal Mine Health and Safety District in which the mine is located no later than June 30, 1974. A copy of this program and any changes shall be filed with the State mine Inspector.
(1) The approved program of instruction shall include a specific fire fighting and evacuation plan designed to acquaint miners on all shifts with procedures for:
(i) Evacuation of all miners not required for fire fighting activities;
(ii) Rapid assembly and transportation of necessary men, fire suppression equipment, and rescue apparatus to the scene of the fire; and,
(iii) Operation of the fire suppression equipment available in the mine.
(2) The approved program of instruction shall be given to all miners annually, and to newly employed miners within six months after the date of employment.
(b) In addition to the approved program of instruction required by paragraph (a) of this section, each operator of an underground coal mine shall ensure that:
(1) At least two miners in each working section on each production shift are proficient in the use of all fire suppression equipment available on such working section, and know the location of such fire suppression equipment;
(2) Each operator of attended equipment specified in S75.1107-1(c)(1), and each miner assigned to perform job duties at the job site in the direct line of sight of attended equipment as described in S 75.1107-1(c)(2), is proficient in the use of fire suppression devices installed on such attended equipment; and,
(3) The shift foreman and at least one miner for every five miners working underground on a maintenance shift are proficient in the use of fire suppression equipment available in the mine, and know the location of such fire suppression equipment.
(c) Each operator of an underground coal mine shall require all miners to participate in fire drills, which shall be held at periods of time so as to ensure that all miners participate in such a drill no later than January 31, 1974, and at intervals of not more than 90 days thereafter.
(1) The operator shall certify by signature and date that the fire drills were held in accordance with the requirements of this section. Certifications shall be kept at the mine and made available on request to an authorized representative of the Secretary.
(2) For purposes of this paragraph (c), a fire drill shall consist of a simulation of the actions required by the approved fire fighting and evacuation plan described in paragraph (a)(1) of this section.
S 75.1102 Slippage and sequence switches.
[Statutory Provisions]
Underground belt conveyors shall be equipped with slippage and sequence switches.
S 75.1103 Automatic fire warning devices.
[Statutory Provisions]
On or before May 29, 1970, devices shall be installed on all such belts which will give a warning automatically when a fire occurs on or near such belt. The Secretary shall prescribe a schedule for installing fire suppression devices on belt haulageways.
S 75.1103-1 Automatic fire sensors.
A fire sensor system shall be installed on each underground belt conveyor. Sensors so installed shall be of a type which will (a) give warning automatically when a fire occurs on or near such belt; (b) provide both audible and visual signals that permit rapid location of the fire.
S 75.1103-2 Automatic fire sensors; approved components; installation requirements.
(a) The components of each automatic fire sensor required to be installed in accordance with the provisions of S 75.1103-1 shall be of a type and installed in a manner approved by the Secretary, or the components shall be of a type listed, approved and installed in accordance with the recommendations of nationally recognized testing laboratory approved by the Secretary.
(b) Where applicable, and not inconsistent with these regulations, automatic fire sensors shall be installed in accordance with the recommendations set forth in National Fire Code No. 72A "Local Protective Signaling Systems" (NFPA No. 72A-1967). National Fire Code No. 72A (1967) is hereby incorporated by reference and made a part hereof. National Fire Code No. 72A is available for examina- tion at each Coal Mine Health and Safety District and Subdistrict Office of the Mine Safety and Health Administration, and may be obtained from the National Fire Protection Association, 60 Batterymarch Street, Boston, MA 02110.
S 75.1103-3 Automatic fire sensor and warning device systems; minimum requirements; general.
Automatic fire sensor and warning device systems installed in belt haulageways of underground coal mines shall be assembled from components which meet the minimum requirements set forth in SS 75.1103-4 through 75.1103-7 unless otherwise approved by the Secretary.
S 75.1103-4 Automatic fire sensor and warning device systems; installation; minimum requirements.
(a) Automatic fire sensor and warning device systems shall provide identification of fire within each belt flight (each belt unit operated by a belt drive).
1) Where used, sensors responding to temperature rise at a point (point-type sensors) shall be located at or above the elevation of the top belt, and installed at the beginning and end of each belt flight, at the belt drive, and in increments along each belt flight so that the maximum distance between sensors does not exceed 125 feet, except as provided in paragraph (a)(3) of this section.
(2) Where used, sensors responding to radiation, smoke, gases, or other indications of fire, shall be spaced at regular intervals to provide protection equivalent to point-type sensors, and installed within the time specified in paragraph (a)(3) of this section.
(3) When the distance from the tailpiece at loading points to the first outby sensor reaches 125 feet when point-type sensors are used, such sensors shall be installed and put in operation within 24 production shift hours after the distance of 125 feet is reached. When sensors of the kind described in paragraph (a)(2) of this section are used, such sensor shall be installed and put in operation within 24 production shift hours after the equivalent distance which has been established for the sensor from the tailpiece at loading points to the first outby sensor is first reached.
(b) Automatic fire sensor and warning device systems shall be installed so as to minimize the possibility of damage from roof falls and the moving belt and its load.
(c) Infrared, ultraviolet, and other sensors whose effectiveness is impaired by contamination shall be protected from dust, dirt, and moisture.
(d) The voltage of automatic fire sensor and warning device systems shall not exceed 120 volts.
(e) Except when power must be cut off in the mine under the provisions of S 75.313, automatic fire sensor and warning device systems shall be capable of giving warning of fire for a minimum of 4 hours after the source of power to the belt is removed unless the belt haulageway is examined for hot rollers and fire as provided in paragraph (e)(1) or (2) of this section.
(1) When an unplanned removal of power from the belt occurs an examination for hot rollers and fire in the operating belts of a conveyor system shall be completed within 2 hours after the belt has stopped.
(2) When a preplanned removal of power from the belt occurs an examination for hot rollers and fire on the operating belts of a conveyor system may commence not more than 30 minutes before the belts are stopped and shall be completed within 2 hours after the examination is commenced, or the examination shall be commenced when the belts are stopped and completed within 2 hours after the belts are stopped.
S 75.1103-5 Automatic fire warning devices; manual resetting.
(a) Automatic fire sensor and warning device systems shall upon activation provide an effective warning signal at either of the following locations:
(1) At all work locations where men may be endangered from a fire at the belt flight; or
(2) At a manned location where personnel have an assigned post of duty and have telephone or equivalent communication with all men who may be endangered.
The automatic fire sensor and warning device system shall be monitored for a period of 4 hours after the belt is stopped, unless an examination for hot rollers and fire is made as prescribed in S 75.1103-4(e).
(b) The fire sensor and warning device system shall include a means for rapid evaluation of electrical short and open circuits, ground faults, pneumatic leaks, or other defect detrimental to its proper operational condition.
(c) Automatic fire sensor and warning devices shall include a manual reset feature.
S 75.1103-6 Automatic fire sensors; actuation of fire suppression systems.
Automatic fire sensor and warning device systems may be used to actuate deluge-type water systems, foam generator systems, multipurpose dry-powder systems, or other equivalent automatic fire suppression systems.
S 75.1103-7 Electrical components; permissibility requirements.
The electrical components of each automatic fire sensor and warning device system shall:
(a) Remain functional when the power circuits are deenergized as required by S 75.706; and
(b) Be provided with protection against ignition of methane or coal dust when the electrical power is deenergized as required by S 75.313, but these components shall be permissible or intrinsically safe if installed in a return airway.
S 75.1103-8 Automatic fire sensor and warning device systems; inspection and test requirements.
(a) Automatic fire sensor and warning device systems shall be inspected weekly, and a functional test of the complete system shall be made at least once annually. Inspection and maintenance of such systems shall be by a qualified person.
(b) A record of the annual functional test conducted in accordance with paragraph (a) of this section shall be maintained by the operator. A record card of the weekly inspection shall be kept at each belt drive.
S 75.1103-9 Minimum requirements; fire suppression materials and location; maintenance of entries and crosscuts; access doors; communications; fire crews; high-expansion foam devices.
(a) The following materials shall be stored within 300 feet of each belt drive or at a location where the material can be moved to the belt drive within 5 minutes, except that when the ventilating current in the belt haulageway travels in the direction of the normal movement of coal on the belt, the materials shall be stored within 300 feet of the belt tailpiece or at a location where the materials can be moved to the belt tailpiece within 5 minutes.
(1) 500 feet of fire hose, except that if the belt flight is less than 500 feet in length the fire hose may be equal to the length of the belt flight. A high expansion foam device may be substituted for 300 feet of the 500 feet of the fire hose. Where used, such foam generators shall produce foam sufficient to fill 100 feet of the belt haulageway in not more than 5 minutes. Sufficient power cable and water hose shall be provided so that the foam generator can be installed at any crosscut along the belt by which the generator is located. A 1-hour supply of foam producing chemicals and tools and hardware required for its operation shall be stored at the foam generator.
(2) Tools to open a stopping between the belt entry and the adjacent intake entry; and
(3) 240 pounds of bagged rock dust.
(b) The entry containing the main waterline and the crosscuts containing water outlets between such entry and the belt haulageway (if the main waterline is in an adjacent entry) shall be maintained accessible and in safe condition for travel and firefighting activities. Each stopping in such crosscuts or adjacent crosscuts shall have an access door.
(c) Suitable communication lines extending to the surface shall be provided in the belt haulage- way or adjacent entry.
(d) The fire suppression system required at the belt drive shall include the belt discharge head.
(e) A crew consisting of at least five members for each working shift shall be trained in firefighting operations. Fire drills shall be held at intervals not exceeding 6 months.
S 75.1103-10 Fire suppression systems; additional requirements.
Where the average air velocity along the belt haulage entry exceeds 100 feet per minute, or the belt is not fire resistant, or both, the fire suppression system in the belt haulageway shall conform with the following additional sensor and cache requirements:
(a) The maximum distance between sensors along the belt haulageway shall be 40 percent of those distances specified or established in accordance with S 75.1103-4(a)(1) or (2), as applicable, and shall be installed and put in operation within the period of time specified in S 75.1103-4(a)(3).
(b) For each conveyor belt flight exceeding 2,000 feet in length, an additional cache of the materials specified in S 75.1103-9(a)(1), (2), and (3) shall be provided. The additional cache may be stored at the locations specified in S 75.1103-9(a), or at some other strategic location readily accessible to the conveyor belt flight.
S 75.1103-11 Tests of fire hydrants and fire hose; record of tests.
Each fire hydrant shall be tested by opening to insure that it is in operating condition, and each fire hose shall be tested, at intervals not exceeding 1 year. A record of these tests shall be maintained at an appropriate location.
S 75.1104 Underground storage, lubricating oil and grease.
[Statutory Provisions]
Underground storage places for lubricating oil and grease shall be of fireproof construction.
Except for specially prepared materials approved by the Secretary, lubricating oil and grease kept in all underground areas in a coal mine shall be in fireproof, closed metal containers or other no less effective containers approved by the Secretary.
S 75.1106 Welding, cutting, or soldering with arc or flame underground.
[Statutory Provisions]
All welding, cutting, or soldering with arc or flame in all underground areas of a coal mine shall, whenever practicable, be conducted in fireproof enclosures. Welding, cutting, or soldering with arc or flame in other than a fireproof enclosure shall be done under the supervision of a qualified person who shall make a diligent search for fire during and after such operations and shall, immediately before and during such operations, continuously test for methane with means approved by the Secretary for detect- ing methane. Welding, cutting, or soldering shall not be conducted in air that contains 1.0 volume per centum or more of methane. Rock dust or suitable fire extinguishers shall be immediately available during such welding, cutting or soldering.
S 75.1106-1 Test for methane.
Until December 31, 1970, a permissible flame safety lamp may be used to make tests for meth- ane required by the regulations in this part. On and after December 31, 1970, a methane detector ap- proved by the Secretary shall be used for such tests and a permissible flame safety lamp may be used as a supplemental testing device. A person qualified to test for methane under S 75.151 will be a qualified person for the purpose of this section.
TRANSPORTATION, HANDLING AND STORAGE OF LIQUEFIED AND NONLIQUEFIED COMPRESSED GAS CYLINDERS
S 75.1106-2 Transportation of liquefied and nonliquefied compressed gas cylinders; requirements.
(a) Liquefied and nonliquefied compressed gas cylinders transported into or through an under- ground coal mine shall be:
(1) Placed securely in devices designed to hold the cylinder in place during transit on self-propelled equipment or belt conveyors;
(2) Disconnected from all hoses and gages;
(3) Equipped with a metal cap or "headband" (fence-type metal protector around the valve stem) to protect the cylinder valve during transit; and,
(4) Clearly labeled "empty" or "MT" when the gas in the cylinder has been expended.
(b) In addition to the requirements of paragraph (a) of this section, when liquefied and nonliquefied compressed gas cylinders are transported by a trolley wire haulage system into or through an underground coal mine, such cylinders shall be placed in well insulated and substantially constructed containers which are specifically designed for holding such cylinders.
(c) Liquefied and nonliquefied compressed gas cylinders shall not be transported on mantrips.
S 75.1106-3 Storage of liquefied and nonliquefied compressed gas cylinders; requirements.
(a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall be:
(1) Clearly marked and identified as to their contents in accordance with Department of Trans- portation regulations.
(2) Placed securely in storage areas designated by the operator for such purpose, and where the height of the coalbed permits, in an upright position, preferably in specially designated racks, or other- wise secured against being accidently tipped over.
(3) Protected against damage from falling material, contact with power lines and energized electrical equipment, heat from welding, cutting or soldering, and exposure to flammable liquids.
(b) Liquefied and nonliquefied compressed gas cylinders shall not be stored or left unattended in any area inby the last open crosscut of an underground coal mine.
(c) When not in use, the valves of all liquefied and nonliquefied compressed gas cylinders shall be in the closed position, and all hoses shall be removed from the cylinder.
S 75.1106-4 Use of liquefied and nonliquefied compressed gas cylinders; general requirements.
(a) Persons assigned by the operator to use and work with liquefied and nonliquefied compressed gas shall be trained and designated by the operator as qualified to perform the work to which they are assigned, and such qualified persons shall be specifically instructed with respect to the dangers inherent in the use of such gases in an underground coal mine.
(b) Persons who perform welding, cutting, or burning operations shall wear clothing free from excessive oil or grease.
(c) Liquefied and nonliquefied compressed gas shall be used only in well-ventilated areas.
(d) Not more than one liquefied or nonliquefied compressed gas unit, consisting of one oxygen cylinder and one additional gas cylinder, shall be used to repair any unit of equipment which is inby the loading point of any section.
(e) Where liquefied and nonliquefied compressed gas is used regularly in underground shops or other underground structures, such shops or structures shall be on a separate split of air.
(f) Where liquefied and nonliquefied compressed gas is used in any area in which oil, grease, or coal dust is present, oil and grease deposits shall, where practicable, be removed and the entire area within 10 feet of the worksite covered with a heavy coating of rock dust.
(g) Liquefied and nonliquefied compressed gas cylinders shall be located no less than 10 feet from the worksite, and where the height of the coal seam permits, they shall be placed in an upright position and chained or otherwise secured against falling.
(h) Liquefied and nonliquefied compressed gas shall not be used under direct pressure from the cylinder and, where such gases are used under reduced pressure, the pressure level shall not exceed that recommended by the manufacturer.
(i) "Manifolding cylinders" shall only be performed in well-ventilated shops where the necessary equipment is properly installed and operated in accordance with specifications for safety prescribed by the manufacturer.
S 75.1106-5 Maintenance and tests of liquefied and nonliquefied compressed gas cylinders; acces- sories and equipment; requirements.
(a) Hose lines, gages, and other cylinder accessories shall be maintained in a safe operating condition.
(b) Defective cylinders, cylinder accessories, torches, and other welding, cutting, and burning equipment shall be labeled "defective" and taken out of service.
(c) Each qualified person assigned to perform welding, cutting, or burning with liquefied and nonliquefied compressed gas shall be equipped with a wrench specifically designed for use with lique- fied and nonliquefied compressed gas cylinders and a suitable torchtip cleaner to maintain torches in a safe operating condition.
(d) Tests for leaks on the hose valves or gages of liquefied and nonliquefied compressed gas cylinders shall only be made with a soft brush and soapy water or soap suds, or other device approved by the Secretary.
S 75.1106-6 Exemption of small low pressure gas cylinders containing nonflammable or nonexplo- sive gas mixtures.
Small low pressure gas cylinders containing nonflammable or nonexplosive gas mixtures, which provide for the emission of such gas under a pressure reduced from a pressure which does not exceed 250 p.s.i.g., and which is manufactured and sold in conformance with U.S. Department of Transportation Special Permit No. 6029 as a calibration test kit for methane monitoring systems, shall be exempt from the requirements of SS 75.1106-2(c) and 75.1106-4(d), (f) and (g).
FIRE SUPPRESSION DEVICES AND FIRE-RESISTANT HYDRAULIC FLUIDS ON UNDER- GROUND EQUIPMENT
S 75.1107 Fire suppression devices.
[Statutory Provisions]
On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the Secretary shall be installed on unattended underground equipment and suitable fire-resistant hydraulic fluids approved by the Secretary shall be used in the hydraulic systems of such equipment. Such fluids shall be used in the hydraulic systems of other underground equipment unless fire suppression devices meeting specifications prescribed by the Secretary are installed on such equipment.
S 75.1107-1 Fire-resistant hydraulic fluids and fire suppression devices on underground equipment.
(a)(1) Unattended electrically powered equipment used underground which uses hydraulic fluid shall use approved fire-resistant hydraulic fluid.
(2) Except as provided in paragraph (a)(3) of this section, within 24 production shift hours after being installed, unattended electrically powered equipment used underground shall be equipped with a fire suppression device which meets the applicable requirements of SS 75.1107-3 through 75.1107-16.
(3) Unattended enclosed motors, controls, transformers, rectifiers, and other similar noncombus- tible electrically powered equipment containing no flammable fluid may be protected:
(i) By an approved fire suppression device, or
(ii) Be located at least 2 feet from coal or other combustible materials, or
(iii) Be separated from the coal or combustible materials by a 4-inch-thick masonry firewall or equivalent; and be mounted on a minimum 4-inch-thick noncombustible surface, platform, or equivalent. The electrical cables at such equipment shall conform with the requirements of part 18 of this chapter (Bureau of Mines Schedule 2G) or be in metal conduit.
(b) Attended electrically powered equipment used underground which uses hydraulic fluid shall use approved fire-resistant hydraulic fluid unless such equipment is protected by a fire suppression device which meets the applicable requirements of SS 75.1107-3-75.1107-16.
(c) For purpose of SS 75.1107--75.1107-16 the following underground equipment shall be con- sidered attended equipment:
(1) Any machine or device regularly operated by a miner assigned to operate such machine or device;
(2) Any machine or device which is mounted in the direct line of sight of a jobsite which is located within 500 feet of such machine or device and which jobsite is regularly occupied by a miner assigned to perform job duties at such jobsite during each production shift.
(d) Machines and devices described under paragraph (c) of this section must be inspected for fire and the input powerline deenergized when workmen leave the area for more than 30 minutes.
S 75.1107-2 Approved fire-resistant hydraulic fluids; minimum requirements.
Fire-resistant hydraulic fluids and concentrates required to be employed in the hydraulic system of underground equipment in accordance with the provisions of S 75.1107-1 shall be considered suitable only if they have been produced under an approval, or any modification thereof, issued pursuant to part 35 pubchapter I of this chapter (Bureau of Mines Schedule 30), or any revision thereof.
S 75.1107-3 Fire suppression devices; approved components; installation requirements.
(a) The components of each fire suppression device required to be installed in accordance with the provisions of S 75.1107-1 shall be approved by the Secretary, or where appropriate be listed as approved by a nationally recognized agency approved by the Secretary.
(b) Where used, pressure vessels shall conform with the requirements of sections 3603, 3606, 3607, 3707, and 3708 of National Fire Code No. 22 "Water Tanks for Private Fire Protection" (NFPA No. 22-1971).
(c) The cover of hose of fire suppression devices, if used on the protected equipment and in- stalled after the effective date of this section, shall meet the flame-resistant requirements of part 18 of this chapter (Bureau of Mines Schedule 2G).
(d) Fire suppression devices required to be installed in accordance with the provisions of S 75.1107-1 shall where appropriate be installed in accordance with the manufacturer's specifications.
S 75.1107-4 Automatic fire sensors and manual actuators; installation; minimum requirements.
(a)(1) Where fire suppression devices are installed on unattended underground equipment, one or more point-type sensors or equivalent shall be installed for each 50 square feet of top surface area, or fraction thereof, of such equipment, and each sensor shall be designed to activate the first suppression system and disconnect the electrical power source to the equipment protected, and, except where sprin- klers are used, there shall be in addition, a manual actuator installed to operate the system. Where sprin- klers are used, provision shall be made for manual application of water to the protected equipment in lieu of a manual actuator.
(2) Two or more manual actuators, where practicable, shall be installed, as provided in para- graphs (a)(2)(i) and (ii) of this section, to activate fire suppression devices on attended equipment pur- chased on or after the effective date of this S 75.1107-4. At least one manual actuator shall be used on equipment purchased prior to the effective date of this S 75.1107-4.
(i) Manual actuators installed on attended equipment regularly operated by a miner, as provided in S 75.1107-1(c)(1) shall be located at different locations on the equipment, and at least one manual actuator shall be located within easy reach of the operator's normal operating position.
(ii) Manual actuators to activate fire suppression devices on attended equipment not regularly operated by a miner, as provided in S 75.1107-1(c)(2), shall be installed at different location, and at least one manual actuator shall be installed so as to be easily reached by the miner at the jobsite or by persons approaching the equipment.
(b) Sensors shall, where practicable, be installed in accordance with the recommendations set forth in National Fire Code No. 72A "Local Protective Signaling Systems" (NFPA No. 72A-1967).
(c) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.
(d) Point-type sensors (such as thermocouple, bimetallic strip, or rate of temperature rise) located in ventilated passageways shall be installed downwind from the equipment to be protected.
(e) Sensor systems shall include a device or method for determining their operative condition.
S 75.1107-5 Electrical components of fire suppression devices; permissibility requirements.
The electrical components of each fire suppression device used on permissible equipment inby the last open crosscut or on equipment in the return airways of any coal mine shall be permissible or intrinsically safe and such components shall be maintained in permissible or intrinsically safe condition.
S 75.1107-6 Capacity of fire suppression devices; location and direction of nozzles.
(a) Each fire suppression device shall be:
(1) Adequate in size and capacity to extinguish potential fires in or on the equipment protected; and
(2) Suitable for the atmospheric conditions surrounding the equipment protected (e.g., air velocity, type, and proximity of adjacent combustible material); and
(3) Rugged enough to withstand rough usage and vibration when installed on mining equipment.
(b) The extinguishant-discharge nozzles of each fire suppression device shall, where practicable, be located so as to take advantage of mine ventilation air currents. The fire suppression device may be of the internal injection, inundating, or combination type. Where fire control is achieved by internal injec- tion, or combination of internal injection and inundation, hazardous locations shall be enclosed to minimize runoff and overshoot of the extinguishing agent and the extinguishing agent shall be directed onto:
(1) Cable reel compartments and electrical cables on the equipment which are subject to flexing or to external damage; and
(2) All hydraulic components on the equipment which are exposed directly to or located in the immediate vicinity of electrical cables which are subject to flexing or to damage.
S 75.1107-7 Water spray devices; capacity; water supply; minimum requirements.
(a) Where water spray devices are used on unattended underground equipment the rate of flow shall be at least 0.25 gallon per minute per square foot over the top surface area of the equipment and the supply of water shall be adequate to provide the required flow of water for 10 minutes.
(b) Where water spray devices are used for inundating attended underground equipment the rate of flow shall be at least 0.18 gallon per minute per square foot over the top surface area of the equipment (excluding conveyors, cutters, and gathering heads), and the supply of water shall be adequate to provide the required flow of water for 10 minutes.
(c) Where water is used for internal injection on attended equipment the total quantity of water shall be at least 4.5 gallons times the number of hazardous locations; however, the total minimum amount of water shall not be less than the following:
The rate of flow shall be not less than 7 gallons per minute.
(d) Where water is used in a combination internal injection and inundation system on attended equipment the rate of flow shall be at least 0.12 gallon per minute per square foot over the top surface area of the equipment (excluding conveyors, cutters, and gathering heads), and the supply of water shall be adequate to provide the required flow of water for 10 minutes.
(e) On equipment provided with a cable reel and an internal injection or combination-type sys- tem, the amount of water discharged into the cable reel compartments shall be approximately 25 percent of the amount required to be discharged by the system, however, such quantity need not exceed 10 gallons.
(f) Liquid chemicals may be used, as approved by the Secretary in self-contained fire suppression devices. Such liquid chemicals shall be nontoxic and when applied to a fire shall not produce excessive toxic compounds. The quantity of liquid chemicals required shall be proportionately less than water as based on equivalency ratings established by the Secretary or equivalency ratings made by a nationally recognized agency approved by the Secretary.
S 75.1107-8 Fire suppression devices; extinguishant supply systems.
(a) Fire suppression systems using water or liquid chemical to protect attended equipment shall:
(1) Be maintained at a pressure consistent with the pipe, fittings, valves, and nozzles used in the system.
(2) Be located so as to be protected against damage during operation of the equipment protected.
(3) Employ liquid which is free from excessive sediment and noncorrosive to the system.
(4) Include strainers equipped with flush-out connections or equivalent protective devices and a rising stem or other visual indicator-type shutoff valve.
(b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water tanks or by connection to water mains. Such water supplies shall be con- tinuously connected to the fire suppression device whenever the equipment is connected to a power source, except for a reasonable time for changing hose connections to hydrants while the machine is stopped in a ventilated passageway.
S 75.1107-9 Dry chemical devices; capacity; minimum requirements.
(a) Dry chemical fire extinguishing systems used on underground equipment shall be of the multipurpose powder-type and shall include the following:
(1) The system including all hose and nozzles shall be protected against the entrance of moisture, dust, or dirt;
(2) The system shall be guarded against damage during operation of the equipment protected;
(3) Hose and pipe shall be as short as possible; the distance between the chemical container and furthest nozzle shall not exceed 50 feet;
(4) Hose, piping, and fittings between the actuator and the chemical container shall have a burst- ing pressure of 500 pounds per square inch (gage) or higher; the hose, piping, and fittings between the chemical container and the nozzles shall have a bursting pressure of 300 pounds per square inch (gage) or higher and
(5) The system shall discharge in 1 minute or less, for quantities less than 50 pounds (nominal) (fn.1) and in less than 2 minutes for quantities more than 50 pounds;
----------
(fn. 1) Many dry chemical systems were originally designed for sodium bicarbonate before all-purpose chemical (ammonium phosphate) was shown to be more effective. Sodium bicarbonate is denser than ammonium phosphate; hence, for example, a 50-pound system designed for the sodium bicarbonate will hold slightly more by weight than all-purpose dry chemical (ammonium phosphate) by weight. The word "nominal" is used in S 75.1107-9 to express the approximate weight in pounds of all-purpose dry chemi- cal.
----------
(b) On unattended underground equipment, the number of pounds of dry chemical employed by the system shall be not less than 1 pound per square foot of top surface area of the equipment; however, the minimum amount in any system shall be 20 pounds (nominal). The discharge shall be directed into and on potentially hazardous locations of the equipment.
(c) On attended underground equipment, the number of pounds (nominal) employed by the system shall equal 5 times the total number of hazardous locations; however, the minimum amount in any system shall not be less than the following, except that systems on haulage vehicles installed prior to the effective date of this section may contain 20 pounds (nominal).
Type of equipment Dry chemical pounds (nominal)
(1) Cutting machines 40
(2) Continuous miners 40
(3) Haulage vehicles 30
(4) All other attended equipment 20
(d) The amount of dry chemical discharged into the cable reel compartments of attended under- ground equipment shall be approximately 25 percent of the total amount required to be discharged by the system; however, the quantity discharged into cable reel compartments need not exceed 10 pounds.
S 75.1107-10 High expansion foam devices; minimum capacity.
(a) On unattended underground equipment the amount of water delivered as high expansion foam for a period of approximately 20 minutes shall be not less than 0.06 gallon per minute per square foot of surface area of the equipment protected; however, the minimum total rate for any system shall be not less than 3 gallons per minute.
(b) On attended underground equipment, foam may be delivered by internal injection, inunda- tion, or combination-type systems. Each system shall deliver water as foam for a minimum of 10 min- utes. For internal injection, the rate of water application as high expansion foam shall be not less than 0.5 gallon per minute per hazardous location; however, the minimum total rate shall be not less than 2 gallons per minute. For inundation, the rate of water application as high expansion foam shall be not less than 0.05 gallon per minute per square foot of top surface area of the equipment protected; however, the minimum total rate shall be not less than 5 gallons of water per minute.
(c) In combined internal injection and inundation systems the rate of water applied as foam shall not be less than 0.035 gallon per minute per square foot of top surface area of the equipment protected; however, the minimum total rate shall not be less than 3.5 gallons of water per minute.
(d) Where internal injection is employed, the amount of water discharged as high expansion foam into the cable reel compartments of underground equipment regularly operated by a miner shall be approximately 25 percent of the total amount required to be discharged by the system; however, the quantity of water discharged as foam into the cable reel compartment need not exceed 1.5 gallons.
S 75.1107-11 Extinguishing agents; requirements on mining equipment employed in low coal.
On mining equipment no more than 32 inches high, the quantity of extinguishing agent required under the provisions of SS 75.1107-7, 75.1107-9, and 75.1107-10 may be reduced by one-fourth if space limitations on the equipment require such reduction.
S 75.1107-12 Inerting of mine atmosphere prohibited.
No fire suppression device designed to control fire by total flooding shall be installed to protect unattended underground equipment except in enclosed dead-end entries or enclosed rooms.
S 75.1107-13 Approval of other fire suppression devices.
Notwithstanding the provisions of SS 75.1107-1 through 75.1107-12 the District Manager for the District in which the mine is located may approve any other fire suppression system or device which provides substantially equivalent protection as would be achieved through compliance with those sec- tions: Provided, That no such system or device shall be approved which does not meet the following minimum criteria:
(a) Components shall be approved by the Secretary, or where appropriate be listed as approved by nationally recognized agency approved by the Secretary.
(b) The fire suppression equipment shall be designed to withstand the rigors of the mine environ- ment. Where used, pressure vessels shall conform with the requirements of section 3603, 3606, 3607, 3707, and 3708 of National Fire Code No. 22 "Water Tanks for Private Fire Protection" (NFPA No.22-1971).
(c) The cover of hose of fire suppression devices, if used on the protected equipment, shall meet the flame-resistant requirements of part 18 of this chapter (Bureau of Mines Schedule 2G).
(d) Extinguishing agents shall not create a serious toxic or other hazard to the miners.
(e) The electrical components of the fire suppression device shall meet the requirements for electrical components of the mining machine.
(f) Where used, manual actuators for initiating the operation of the fire suppression device shall be readily accessible to the machine operator. On unattended equipment, an automatic as well as a manual actuator shall be provided.
(g) On unattended equipment the fire suppression device shall operate independently of the power to the main motor (or equivalent) so it will remain operative if the circuit breakers (or other protective device) actuates. On attended equipment powered through a trailing cable the fire suppression device shall operate independently of the electrical power provided by the cable.
(h) On unattended equipment, the sensor system shall have a means for checking its operative condition.
(i) The fire suppression agent shall be directed at locations where the greatest potential fire hazard exists. Cable reel compartments shall receive approximately twice the quantity of extinguishing agent as each other hazardous location.
(j) The rate of application of the fire suppression agent shall minimize the time for quenching and the total quantity applied shall be sufficient to quench a fire in its incipient stage.
(k) The effectiveness of the quenching agent, together with the total quantity of agent and its rate of application shall provide equivalent protection to the water, dry powder, or foam systems described in SS 75.1107-7, 75.1107-9, and 75.1107-10.
(l) The fire suppression device shall be operable at all times electrical power is connected to the mining machine, except during tramming when the machine is in a ventilated passageway, the water hose if used, may be switched from one hydrant to another in a reasonable time and except in systems meeting the minimum special criteria set forth in paragraph (m) of this section.
(m) Systems for attended equipment which are not continuously connected to a water supply shall not be approved unless they meet the following minimum criteria:
(1) The machine shall be equipped with a firehose at least 50 feet in length which is continuously connected to the machine-mounted portion of the system.
(2) Hydrants in proximity to the area where the machine is to be used shall be equipped with sufficient hose to reach the machine at any time it is connected to a power source.
(3) The machine shall be used only where the operator (or other person) will always be in venti- lated air uncontaminated by smoke and hot gases from the machine fire while extending the machine-mounted hose to connect with the hydrant-mounted hose.
(4) The machine and hydrant hoses shall be readily accessible so that the connection between the machine-mounted hose and the hydrant hose can be made and water flow achieved in not more than 3 minutes under actual mining conditions for any location of the machine while electric power is con- nected.
(5) The rate of water flow at the machine shall provide a minimum of 0.12 gallon of water per minute per square foot of top surface area (excluding conveyors, cutters, and gathering heads). The water shall discharge to all hazardous locations on the machine.
(6) Hose, if used on the machine, in addition to meeting the flame resistant requirements for the cover of a hose provided in SS 75.1107-3(b) and 75.1107-13(c) shall have a minimum burst pressure 4 times that of the static water pressure at the mining machine. Fabric braid hose shall have at least two braids, and wire braid hose shall have at least a single braid.
(7) In addition to the hose located at the hydrant (which is intended to be connected to the hose on the machine) the firefighting equipment required by S 75.1100-2(a) shall be maintained.
(8) A sufficient number of trained miners shall be kept on the section when the machine is in use to connect the machine hose to the hydrant hose and achieve water flow in not more than 3 minutes.
S 75.1107-14 Guards and handrails; requirements where fire suppression devices are employed.
All unattended underground equipment provided with fire suppression devices which are mounted in dead end entries, enclosed rooms or other potentially hazardous locations shall be equipped with adequate guards at moving or rotating components. Handrails or other effective protective devices shall be installed at such locations where necessary to facilitate rapid egress from the area surrounding such equipment.
S 75.1107-15 Fire suppression devices; hazards; training of miners.
Each operator shall instruct all miners normally assigned to the active workings of the mine with respect to any hazards inherent in the operation of all fire suppression devices installed in accordance with S 75.1107-1 and, where appropriate, the safeguards available at each such installation.
S 75.1107-16 Inspection of fire suppression devices.
(a) All fire suppression devices shall be visually inspected at least once each week by a person qualified to make such inspections.
(b) Each fire suppression device shall be tested and maintained in accordance with the require- ments specified in the appropriate National Fire Code listed as follows for the type and kind of device used:
National Fire Code No. 11A "High Expansion Foam Systems" (NFPA No. 11A-1970).
National Fire Code No. 13A "Care and Maintenance of Sprinkler Systems" (NFPA No. 13A-1971).
National Fire Code No. 15 "Water Spray Fixed Systems for Fire Protection" (NFPA No. 15-1969).
National Fire Code No. 17 "Dry Chemical Extinguishing Systems" (NFPA No. 17-1969).
National Fire Code No. 72A "Local Protective Signaling Systems" (NFPA No. 72A-1967).
National Fire Code No. 198 "Care of Fire Hose" (NFPA No. 198-1969).
(c) A record of the inspections required by this section shall be maintained by the operator. The record of the weekly inspections may be maintained at an appropriate location by each fire suppression device.
S 75.1107-17 Incorporation by reference; availability of publications.
In accordance with 5 U.S.C. 552(a), the technical publications to which reference is made in SS 75.1107-1 through 75.1107-16, and which have been prepared by organizations other than the Bureau of Mines or the Mine Safety and Health Administration, are hereby incorporated by reference and made a part hereof. The incorporated publications are available for examination at each Coal Mine Health and Safety District and Subdistrict Office of the Mine Safety and Health Administration. National Fire Codes are available from the National Fire Protection Association, 60 Batterymarch Street, Boston, MA 02110.
S 75.1108 Flame-resistant conveyor belts.
[Statutory Provisions]
On and after March 30, 1970, all conveyor belts acquired for use underground shall meet the requirements to be established by the Secretary for flame-resistant conveyor belts.
S 75.1108-1 Approved conveyor belts.
Conveyor belts which have been approved as flame-resistant by the Bureau of Mines under part 18 of this chapter (Bureau of Mines Schedule 2G) meet the requirements of S 75.1108.
Subpart M--Maps
S 75.1200 Mine map.
[Statutory Provisions]
The operator of a coal mine shall have in a fireproof repository located in an area on the surface of the mine chosen by the mine operator to minimize the danger of destruction by fire or other hazard, an accurate and up-to-date map of such mine drawn on scale. Such map shall show:
(a) The active workings;
(b) All pillared, worked out, and abandoned areas, except as provided in this section;
(c) Entries and aircourses with the direction of airflow indicated by arrows;
(d) Contour lines of all elevations;
(e) Elevations of all main and cross or side entries;
(f) Dip of the coalbed;
(g) Escapeways;
(h) Adjacent mine workings within 1,000 feet;
(i) Mines above or below;
(j) Water pools above; and
(k) Either producing or abandoned oil and gas wells located within 500 feet of such mine and any underground area of such mine; and,
(l) Such other information as the Secretary may require. Such map shall identify those areas of the mine which have been pillared, worked out, or abandoned, which are inaccessible or cannot be entered safely and on which no information is available.
S 75.1200-1 Additional information on mine map.
Additional information required to be shown on mine maps under S 75.1200 shall include the following:
(a) Name and address of the mine;
(b) The scale and orientation of the map;
(c) The property or boundary lines of the mine;
(d) All drill holes that penetrate the coalbed being mined;
(e) All shaft, slope, drift, and tunnel openings and auger and strip mined areas of the coalbed being mined;
(f) The location of all surface mine ventilation fans; the location may be designated on the mine map by symbols;
(g) The location of railroad tracks and public highways leading to the mine, and mine buildings of a permanent nature with identifying names shown;
(h) The location and description of at least two permanent base line points coordinated with the underground and surface mine traverses, and the location and description of at least two permanent elevation bench marks used in connection with establishing or referencing mine elevation surveys;
(i) The location of any body of water dammed in the mine or held back in any portion of the mine; provided, however, such bodies of water may be shown on overlays or tracings attached to the mine maps used to show contour lines as provided under paragraph (m) of this section;
(j) The elevations of tops and bottoms of shafts and slopes, and the floor at the entrance to drift and tunnel openings;
(k) The elevation of the floor at intervals of not more than 200 feet in:
(1) At least one entry of each working section, and main and cross entries;
(2) The last line of open crosscuts of each working section, and main and cross entries before such sections and main and cross entries are abandoned;
(3) Rooms advancing toward or adjacent to property or boundary lines or adjacent mines;
(l) The elevation of any body of water dammed in the mine or held back in any portion of the mine; and,
(m) Contour lines passing through whole number elevations of the coalbed being mined. The spacing of such lines shall not exceed 10-foot elevation levels, except that a broader spacing of contour lines may be approved by the District Manager for steeply-pitching coalbeds. Contour lines may be placed on overlays or tracings attached to mine maps.
S 75.1200-2 Accuracy and scale of mine maps.
(a) The scale of mine maps submitted to the Secretary shall not be less than 100 or more than 500 feet to the inch.
(b) Mine traverses shall be advanced by closed loop methods of traversing or other equally accurate methods of traversing.
S 75.1201 Certification.
[Statutory Provisions]
Such map shall be made or certified by a registered engineer or a registered surveyor of the State in which the mine is located.
S 75.1202 Temporary notations, revisions, and supplements.
[Statutory Provisions]
Such map shall be kept up-to-date by temporary notations and such map shall be revised and supplemented at intervals prescribed by the Secretary on the basis of a survey made or certified by such engineer or surveyor.
S 75.1202-1 Temporary notations, revisions, and supplements.
(a) Mine maps shall be revised and supplemented at intervals of not more than 6 months.
(b) Temporary notations shall include:
(1) The location of each working face of each working place;
(2) Pillars mined or other such second mining;
(3) Permanent ventilation controls constructed or removed, such as seals, overcasts, undercasts, regulators, and permanent stoppings, and the direction of air currents indicated;
(4) Escapeways designated by means of symbols.
S 75.1203 Availability of mine map.
[Statutory Provisions]
The coal mine map and any revision and supplement thereof shall be available for inspection by the Secretary or his authorized representative, by coal mine inspectors of the State in which the mine is located, by miners in the mine and their representatives and by operators of adjacent coal mines and by persons owning, leasing, or residing on surface areas of such mines or areas adjacent to such mines. The operator shall furnish to the Secretary or his authorized representative, the State Mine Inspector and to the Secretary of Housing and Urban Development, upon request, one or more copies of such maps and any revision and supplement thereof. Such map or revision and supplement thereof shall be kept confidential and its contents shall not be divulged to any other person, except to the extent necessary to carry out the provisions of this Act and in connection with the functions and responsibilities of the Secretary of Housing and Urban Development.
S 75.1204 Mine closure; filing of map with Secretary and the State Mine Inspector.
[Statutory Provisions]
Whenever an operator permanently closes or abandons a coal mine, or temporarily closes a coal mine for a period of more than 90 days, he shall promptly notify the Secretary and the State Mine In- spector of such closure. Within 60 days of the permanent closure or abandonment of the mine, or, when the mine is temporarily closed, upon the expiration of a period of 90 days from the date of closure, the operator shall file with the Secretary and the State Mine Inspector a copy of the mine map revised and supplemented to the date of the closure. Such copy of the mine map shall be certified by a registered surveyor or registered engineer of the State in which the mine is located and shall be available for public inspection.
S 75.1204-1 Places to give notice and file maps.
Operators shall give notice of mine closures and file copies of maps with the Coal Mine Safety District Office for the district in which the mine is located and the State Mine Inspector.
Subpart N--Explosives and Blasting
S 75.1300 Definitions.
The following definitions apply in this subpart.
Approval. A document issued by MSHA which states that an explosive or explosive unit has met the requirements of this part and which authorizes an approval marking identifying the explosive or explosive unit as approved as permissible.
Battery starting. The use of unconfined explosives to start the flow of coal down a breast or chute in an anthracite mine.
Blasting off the solid. Blasting the working face without providing a second free face by cutting, shearing or other method before blasting.
Instantaneous detonator. An electric detonator that fires within 6 milliseconds after application of the firing current.
Laminated partition. A partition composed of the following material and minimum nominal dimensions: 1/2-inch thick plywood, 1/2-inch thick gypsum wall board, 1/8-inch thick low carbon steel and 1/4-inch thick plywood, bonded together in that order.
Opener hole. The first hole or holes fired in a round blasted off the solid to create an additional free face.
Permissible blasting unit. A device that has been approved by MSHA and that is used for firing electric detonators.
Permissible explosive. Any substance, compound or mixture which is approved by MSHA and whose primary purpose is to function by explosion.
Round. A group of boreholes fired or intended to be fired in a continuous sequence with one application of the firing current.
Sheathed explosive unit. A device consisting of an approved or permissible explosive covered by sheath encased in a sealed covering and designed to be fired outside the confines of a borehole.
Short-delay electric detonator. An electric detonator with a designated delay period of 25 to 1,000 milliseconds.
S 75.1301 Qualified person.
(a) A qualified person under this subpart is a person who--
(1) Is certified or qualified to use explosives by the State in which the mine is located provided that the State requires a demonstration of ability to safely use permissible explosives as prescribed by this subpart effective January 17, 1989; or
(2) In States that do not certify or qualify persons to use explosives required by this section, has at least 1 year of experience working in an underground coal mine that includes direct involvement with procedures for handling, loading, and preparing explosives for blasting and demonstrates to an autho- rized representative of the Secretary the ability to use permissible explosives safely.
(b) Persons qualified or certified by a State to use permissible explosives in underground coal mines as of May 17, 1989, are considered qualified under this section even though their State program did not contain a demonstration of ability requirement.
S 75.1310 Explosives and blasting equipment.
(a) Only permissible explosives, approved sheathed explosive units, and permissible blasting units shall be taken or used underground.
(b) Black blasting powder, aluminum-cased detonators, aluminum-alloy-cased detonators, deto- nators with aluminum leg wires, and safety fuses shall not be taken or used underground.
(c) Explosives shall be fired only with a permissible blasting unit used in a manner consistent with its approval. Blasting units approved by MSHA that have approval labels specifying use with short-delay detonators with delay periods between 25-500 milliseconds are accepted to fire short-delay detonators up to 1,000 milliseconds, instantaneous detonators and long period delay detonators for anthracite mines.
(d) Permissible explosives and sheathed explosive units shall not be used underground when they are below the minimum product firing temperature specified by the approval. Explosives previously approved which do not specify a minimum firing temperature are permissible for use so long as the present approval is maintained.
(e) Electric detonators shall be compatible with the blasting unit and have sufficient strength to initiate the explosives being used.
S 75.1311 Transporting explosives and detonators.
(a) When explosives and detonators are to be transported underground--
(1) They shall be enclosed in separate, substantially constructed containers made of nonconduc- tive material, with no metal or other conductive materials exposed inside, except as specified in para- graph (d) of this section; and
(2) Each container of explosives and of detonators shall be indelibly marked with a readily visible warning identifying the contents.
(b) When explosives and detonators are transported by any cars or vehicles--
(1) The cars or vehicles shall be marked with warnings to identify the contents as explosive. The warnings shall be readily visible to miners approaching from any direction and in indelible letters;
(2) Explosives and detonators shall be transported either in separate cars or vehicles, or if in the same cars or vehicles as follows:
(i) Class A and Class C detonators in quantities greater than 1,000 shall be kept in the original containers as shipped from the manufacturer and separated from explosives by a hardwood partition at least 4 inches thick, a laminated partition or equivalent; and
(ii) Class A and Class C detonators in quantities of no more than 1,000 shall be separated from explosives by a hardwood partition at least 4 inches thick, a laminated partition or equivalent.
(3) No persons, other than those necessary to operate the equipment or to accompany the explo- sives and detonators, shall be transported with explosives and detonators, and
(4) When explosives and detonators are transported using trolley locomotives--
(i) Trips carrying explosives and detonators shall be separated from all other mantrips by at least 5-minute interval; and
(ii) Cars containing explosives or detonators shall be separated from the locomotives by at least one car that is empty or that contains noncombustible materials.
(c) When explosives and detonators are transported on conveyor belts--
(1) Containers of explosives shall be separated from containers of detonators by at least 50 feet;
(2) At least 6 inches of clearance shall be maintained between the top of any container of explo- sives or container of detonators and the mine roof or other obstruction;
(3) Except when persons are riding the belt to accompany explosives or detonators, a person shall be at each transfer point between belts and at the unloading location; and
(4) Conveyor belts shall be stopped before explosives or detonators are loaded or unloaded.
(d) When explosives and detonators are transported by hand they shall be carried in separate, nonconductive, closed containers.
S 75.1312 Explosives and detonators in underground magazines.
(a) The quantity of explosives kept underground shall not be more than is needed for 48 hours of use.
(b) Except as provided in S 75.1313, explosives and detonators taken underground shall be kept in--
(1) Separate, closed magazines at least 5 feet apart; or
(2) The same closed magazine when--
(i) Separated by a hardwood partition at least 4 inches thick; or
(ii) Separated by a laminated partition; or
(iii) Separated by a device that is equivalent.
(c) Only explosives and detonators shall be kept in underground magazines.
(d) Magazines shall be substantially constructed and all interior surfaces shall be made of non- conductive material, with no metal or other conductive material exposed inside.
(e) All magazines shall be--
(1) Located at least 25 feet from roadways and any source of electric current;
(2) Located out of the direct line of the forces from blasting; and
(3) Kept as dry as practicable.
(f) Magazine locations shall be posted with indelibly marked and readily visible warnings indi- cating the presence of explosives.
(g) Only materials and equipment to be used in blasting shall be stored at magazine locations.
S 75.1313 Explosives and detonators outside of magazines.
(a) The quantity of explosives outside a magazine for use in a working section or other area where blasting is to be performed shall--
(1) Not exceed 100 pounds; or
(2) Not exceed the amount necessary to blast one round when more than 100 pounds of explo- sives is required.
(b) Explosives and detonators outside a magazine that are not being transported or prepared for loading boreholes shall be kept in closed separate containers made of nonconductive material with no metal or other conductive material exposed inside and the containers shall be--
(1) At least 15 feet from any source of electric current;
(2) Out of the direct line of the forces from blasting;
(3) In a location to prevent damage by mobile equipment; and
(4) Kept as dry as practicable.
(c) Explosives and detonators not used during the shift shall be returned to a magazine by the end of the shift.
S 75.1314 Sheathed explosive units.
(a) A separate instantaneous detonator shall be used to fire each sheathed explosive unit.
(b) Sheathed explosive units shall be primed and placed in position for firing only by a qualified person or a person working in the presence of and under the direction of a qualified person. To prime a sheathed explosive unit, the entire detonator shall be inserted into the detonator well of the unit and be held securely in place.
(c) Sheathed explosive units shall not be primed until immediately before the units are placed where they are to be fired. A sheathed explosive unit shall not be primed if it is damaged or deteriorated.
(d) Except in anthracite mines, rock dust shall be applied to the roof, ribs and floor within a 40-foot radius of the location where the sheathed explosive units are to be fired.
(e) No more than three sheathed explosive units shall be fired at one time.
(f) No sheathed explosive unit shall be fired in contact with another sheathed explosive unit.
S 75.1315 Boreholes for explosives.
(a) All explosives fired underground shall be confined in boreholes except--
(1) Sheathed explosives units and other explosive units approved by MSHA for firing outside the confines of a borehole; and
(2) Shots fired in anthracite mines for battery starting or for blasting coal overhangs. No person shall go inside a battery to start the flow of material.
(b) Each borehole in coal for explosives shall be at least 24 inches from any other borehole and from any free face, unless prohibited by the thickness of the coal seam.
(c) Each borehole in rock for explosives shall be at least 18 inches from any other borehole in rock, at least 24 inches from any other borehole in coal, and at least 18 inches from any free face.
(d) No borehole that has contained explosives shall be used for starting any other hole.
(e) When blasting slab rounds off the solid, opener holes shall not be drilled beyond the rib line.
(f) When coal is cut for blasting, the coal shall be supported if necessary to maintain the stability of the column of explosives in each borehole.
S 75.1316 Preparation before blasting.
(a)(1) All nonbattery-powered electric equipment, including cables, located within 50 feet from boreholes to be loaded with explosives or the sites where sheathed explosive units are to be placed and fired shall be deenergized or removed to at least 50 feet from these locations before priming of explo- sives. Battery-powered equipment shall be removed to at least 50 feet from these locations before prim- ing of explosives.
(2) As an alternative to paragraph (a)(1) of this section, electric equipment, including cables, need not be deenergized or removed if located at least 25 feet from these locations provided stray current tests conducted prior to priming the explosives detect stray currents of 0.05 ampere or less through a 1-ohm resistor.
(i) Tests shall be made at floor locations on the perimeter, on energized equipment frames and on repaired areas of energized cables within the area between 25 to 50 feet from the locations where the explosives are to be primed.
(ii) Tests shall be conducted using a blasting multimeter or other instrument specifically designed for such use.
(3) The blasting cable or detonator circuitry shall not come in contact with energized electric equipment, including cables.
(b) Before loading boreholes with explosives, each borehole shall be cleared and its depth and direction determined.
(c) No borehole drilled beyond the depth of cut coal shall be loaded with explosives unless that portion of the borehole deeper than the cut is tamped with noncombustible material.
(d) When two working faces are approaching each other, cutting, drilling and blasting shall be done at only one working face at a time if the two faces are within 25 feet of each other.
S 75.1317 Primer cartridges.
(a) Primer cartridges shall be primed and loaded only by a qualified person or a person working in the presence of and under the direction of a qualified person.
(b) Primer cartridges shall not be primed until immediately before loading boreholes.
(c) Only a nonsparking punch shall be used when priming explosive cartridges.
(d) Detonators shall be completely within and parallel to the length of the cartridge and shall be secured by half-hitching the leg wires around the cartridge or secured by an equally effective method.
S 75.1318 Loading boreholes.
(a) Explosives shall be loaded by a qualified person or a person working in the presence of and under the direction of a qualified person.
(b) When boreholes are being loaded, no other work except that necessary to protect persons shall be done in the working place or other area where blasting is to be performed.
(c) When loading boreholes drilled at an angle of 45 degrees or greater from the horizontal in solid rock or loading long holes drilled upward in anthracite mines-
(1) The first cartridge in each borehole shall be the primer cartridge with the end of the cartridge containing the detonator facing the back of the borehole; and
(2) The explosive cartridges shall be loaded in a manner that provides contact between each cartridge in the borehole.
(d) When loading other boreholes--
(1) The primer cartridge shall be the first cartridge loaded in the borehole;
(2) The end of the cartridge in which the detonator is inserted shall face the back of the borehole; and
(3) The primer cartridge and other explosives shall be pushed to the back of the borehole in a continuous column with no cartridge being deliberately crushed or deformed.
(e) An explosive shall not be loaded into a borehole if it is damaged, deteriorated or if the car- tridge is incompletely filled.
(f) Explosives of different brands, types or cartridge diameters shall not be loaded in the same borehole.
(g) Only nonconductive, nonsparking tamping poles shall be used for loading and tamping boreholes. The use of nonsparking connecting devices for extendable tamping poles is permitted.
S 75.1319 Weight of explosives permitted in boreholes in bituminous and lignite mines.
(a) The total weight of explosives loaded in any borehole in bituminous and lignite mines shall not exceed 3 pounds except when blasting solid rock in its natural deposit.
(b) The total weight of explosives loaded in a borehole less than 6 feet deep in bituminous and lignite mines shall be reduced by 1/2 pound for each foot of borehole less than 6 feet.
S 75.1320 Multiple-shot blasting.
(a) No more than 20 boreholes shall be fired in a round unless permitted in writing by the District Manager under S 75.1321.
(b) Instantaneous detonators shall not be used in the same circuit with delay detonators in any underground coal mine.
(c) In bituminous and lignite mines, only detonators with delay periods of 1,000 milliseconds or less shall be used.
(d) When blasting in anthracite mines, each borehole in a round shall be initiated in sequence from the opener hole or holes.
(e) Arrangement of detonator delay periods for bituminous and lignite mines shall be as follows:
(1) When blasting cut coal--
(i) The first shot or shots fired in a round shall be initiated in the row nearest the kerf or the row or rows nearest the shear; and
(ii) After the first shot or shots, the interval between the designated delay periods of successive shots shall be at least 50 milliseconds but not more than 100 milliseconds.
(2) When blasting coal off the solid--
(i) Each shot in the round shall be initiated in sequence from the opener hole or holes; and
(ii) After the first shot or shots, the interval between the designated delay periods of successive shots shall be at least 50 milliseconds but not more than 100 milliseconds.
S 75.1321 Permits for firing more than 20 boreholes and for use of nonpermissible blasting units.
(a) Applications for permits for firing more than 20 boreholes in a round and for the use of nonpermissible blasting units shall be submitted in writing to the District Manager for the district in which the mine is located and shall contain the following information:
(1) The name and address of the mine;
(2) The active workings in the mine affected by the permit and the approximate number of boreholes to be fired;
(3) The period of time during which the permit will apply;
(4) The nature of the development or construction for which they will be used, e. g., overcasts, undercasts, track grading, roof brushing or boom holes;
(5) A plan, proposed by the operator designed to protect miners in the mine from the hazards of methane and other explosive gases during each multiple shot, e. g., changes in the mine ventilation system, provisions for auxiliary ventilation and any other safeguards necessary to minimize such haz- ards;
(6) A statement of the specific hazards anticipated by the operator in blasting for overcasts, undercasts, track grading, brushing of roof, boom holes or other unusual blasting situations such as coalbeds of abnormal thickness; and
(7) The method to be employed to avoid the dangers anticipated during development or construc- tion which will ensure the protection of life and the prevention of injuries to the miners exposed to such underground blasting.
(b) The District Manager may permit the firing of more than 20 boreholes of permissible explo- sives in a round where he has determined that it is necessary to reduce the overall hazard to which miners are exposed during underground blasting. He may also permit the use of nonpermissible blasting units if he finds that a permissible blasting unit does not have adequate blasting capacity and that the use of such permissible units will create any of the following development or construction hazards:
(1) Exposure to disturbed roof in an adjacent cavity while scaling and supporting the remaining roof prior to wiring a new series of boreholes;
(2) Exposure to underburden boreholes where prior rounds have removed the burden adjacent to remaining borehole;
(3) Exposure to an unsupported roof while redrilling large fragmented roof rock following the loss of predrilled boreholes during earlier blasting operations; or
(4) Any other hazard created by the use of permissible blasting units during underground devel- opment or construction.
(c) Permits shall be issued on a mine-by-mine basis for periods of time to be specified by the District Manager.
(d) Permits issued under this section shall specify and include as a condition of their use, any safeguards, in addition to those proposed by the operator, which the District Manager issuing such permit has determined will be required to ensure the welfare of the miners employed in the mine at the time of the blasting permitted. A copy of this permit and any changes shall be filed with the State Mine Inspector.
S 75.1322 Stemming boreholes
(a) Only noncombustible material shall be used for stemming boreholes.
(b) Stemming materials other than water stemming bags shall be tamped to fill the entire cross sectional area of the borehole.
(c) Stemming material shall contact the explosive cartridge nearest the collar of the borehole.
(d) Each borehole 4 or more feet deep shall be stemmed for at least 24 inches.
(e) Each borehole less than 4 feet deep shall be stemmed for at least half the depth of the bore- hole.
(f) When blasting off the solid in bituminous and lignite mines, only pliable clay dummies shall be used for stemming.
(g) The diameter of a water stemming bag shall be within 1/4
of an inch of the diameter of the drill bit used to drill the borehole.
(h) Water stemming bags shall be constructed of tear-resistant and flame-resistant material and be capable of withstanding a 3-foot drop when filled without rupturing or developing leaks.
S 75.1323 Blasting circuits.
(a) Blasting circuits shall be protected from sources of stray electric current.
(b) Detonators made by different manufacturers shall not be combined in the same blasting circuit.
(c) Detonator leg wires shall be shunted until connected into the blasting circuit.
(d) Blasting cables shall be--
(1) Well insulated, copper wire of a diameter not smaller than 18-gauge; and
(2) Long enough to permit the round to be fired from a safe location that is around at least one corner from the blasting area.
(e) Blasting cables shall be shunted until immediately before firing, except when testing for circuit continuity.
(f) Wire used between the blasting cable and detonator circuitry shall--
(1) Be undamaged;
(2) Be well insulated;
(3) Have a resistance no greater than 20-gauge copper wire; and
(4) Be not more than 30 feet long.
(g) Each wire connection in a blasting circuit shall be--
(1) Properly spliced; and
(2) Separated from other connections in the circuit to prevent accidental contact and arcing.
(h) Uninsulated connections in each blasting circuit shall be kept out of water and shall not contact the coal, roof, ribs, or floor.
(i) When 20 or fewer boreholes are fired in a round, the blasting circuit shall be wired in a single series.
(j) Immediately prior to firing, all blasting circuits shall be tested for continuity and resistance using a blasting galvanometer or other instrument specifically designed for testing blasting circuits.
S 75.1324 Methane concentration and tests.
(a) No shot shall be fired in an area that contains 1.0 volume percent or more of methane.
(b) Immediately before shots are fired, the methane concentration in a working place or any other area where blasting is to be performed, shall be determined by a person qualified to test for methane.
S 75.1325 Firing procedures.
(a) Shots shall be fired by a qualified person or a person working in the presence of and under the direction of a qualified person.
(b) Only one face in a working place shall be blasted at a time, except that when blasting cut coal up to three faces may be blasted in a round if each face has a separate kerf and no more than a total of 20 shots connected in a single series are fired in the round. A permit to fire more than 20 boreholes in a round under the provisions of 30 CFR 75.1320 and 75.1321 may not be obtained for use when blasting multiple faces.
(c) Before blasting--
(1) All persons shall leave the blasting area and each immediately adjacent working place where hazard would be created by the blast, to an area that is around at least one corner from the blasting area;
(2) The qualified person shall ascertain that all persons are a safe distance from the blasting area; and
(3) A warning shall be given and adequate time allowed for persons to respond.
(d) All shots shall be fired promptly, after all persons have been removed to a safe location.
S 75.1326 Examination after blasting.
(a) After blasting, the blasting area shall not be entered until it is clear of smoke and dust.
(b) Immediately after the blasting area has cleared, a qualified person or a person working in the presence of and under the direction of a qualified person, shall examine the area for misfires, methane and other hazardous conditions.
(c) If a round has partially detonated, the qualified person shall immediately leave the area and no person shall reenter the affected area for at least 5 minutes.
S 75.1327 Misfires.
(a) When misfires occur, only work by a qualified person to dispose of misfires and other work necessary to protect persons shall be done in the affected area.
(b) When a misfire cannot be disposed of--
(1) A qualified person shall post each accessible entrance to the area affected by the hazard of the misfire with a warning at a conspicuous location to prohibit entry; and
(2) The misfire shall be immediately reported to mine management.
S 75.1328 Damaged or deteriorated explosives and detonators.
(a) Damaged explosives or detonators shall be--
(1) Placed in separate containers constructed of nonconductive and nonsparking materials; and
(2) Removed from the mine or placed in a magazine and removed when the magazine is resup- plied.
(b) Damaged detonators shall be shunted, if practicable, either before being removed from the mine or placed in a magazine.
(c) Deteriorated explosives and detonators shall be handled and disposed of in accordance with the instructions of the manufacturer.
Subpart O--Hoisting and Mantrips
S 75.1400 Hoisting equipment; general.
(a) Every hoist used to transport persons shall be equipped with overspeed, overwind, and auto- matic stop controls.
(b) Every hoist handling a platform, cage, or other device used to transport persons shall be equipped with brakes capable of stopping the fully loaded platform, cage, or other device.
(c) Cages, platforms, or other devices used to transport persons in shafts and slopes shall be equipped with safety catches or other no less effective devices approved by the Secretary that act quickly and effectively in an emergency. Such catches or devices shall be tested at least once every two months.
(d) Hoisting equipment, including automatic elevators, used to transport persons shall be exam- ined daily.
(e) Where persons are transported into or out of a mine by a hoist, a qualified hoisting engineer shall be on duty while any person is underground. No such engineer, however, shall be required for automatically operated cages, platforms, or elevators.
S 75.1400-1 Hoists; brakes, capability.
Brakes on hoists used to transport persons shall be capable of stopping and holding the fully loaded platform, cage, or other device at any point in the shaft, slope, or incline.
S 75.1400-2 Hoists; tests of safety catches; records.
A record shall be made in a book of the tests, required by S 75.1400, of the safety catches or other devices approved by the Secretary. Each entry shall be signed by the person making the tests and countersigned by a responsible official.
S 75.1400-3 Daily examination of hoisting equipment.
Hoists and elevators shall be examined daily and such examinations shall include, but not be limited to, the following:
(a) Elevators. A visual examination of the rope for wear, broken wires, and corrosion, especially at excessive strain points such as near the attachments and where the rope rests on sheaves;
(b) Hoists and elevators. (1) An examination of the rope fastenings for defects;
(2) An examination of safety catches;
(3) An examination of the cages, platforms, elevators, or other devices for loose, missing or defective parts;
(4) An examination of the head sheaves to check for broken flanges, defective bearings, rope alignment, and proper lubrication; and
(5) An observation of the lining and all other equipment and appurtenances installed in the shaft.
S 75.1400-4 Certifications and records of daily examinations.
At the completion of each daily examination required by S 75.1400, the person making the examination shall certify, by signature and date, that the examination has been made. If any unsafe condition is found during the examinations required by S 75.1400-3, the person conducting the examina- tion shall make a record of the condition and the date. Certifications and records shall be retained for one year.
S 75.1401 Hoists; rated capacities; indicators.
Hoists shall have rated capacities consistent with the loads handled. An accurate and reliable indicator of the position of the cage, platform, skip, bucket, or cars shall be provided.
S 75.1401-1 Hoists; indicators.
The indicator required by S 75.1401 of this subpart shall be placed so that it is in clear view of the hoisting engineer and shall be checked daily to determine its accuracy.
S 75.1402 Communication between shaft stations and hoist room.
[Statutory Provisions]
There shall be at least two effective methods approved by the Secretary of signaling between each of the shaft stations and the hoist room, one of which shall be a telephone or speaking tube.
S 75.1402-1 Communication between shaft stations and hoist room.
One of the methods used to communicate between shaft stations and the hoist room shall give signals which can be heard by the hoisting engineer at all times while men are underground.
S 75.1402-2 Tests of signaling systems.
Signaling systems used for communication between shaft stations and the hoist room shall be tested daily.
S 75.1403 Other safeguards.
[Statutory Provisions]
Other safeguards adequate, in the judgment of an authorized representative of the Secretary, to minimize hazards with respect to transportation of men and materials shall be provided.
S 75.1403-1 General criteria.
(a) Sections 75.1403-2 through 75.1403-11 set out the criteria by which an authorized representa- tive of the Secretary will be guided in requiring other safeguards on a mine-by-mine basis under S 75.1403. Other safeguards may be required.
(b) The authorized representative of the Secretary shall in writing advise the operator of a spe- cific safeguard which is required pursuant to S 75.1403 and shall fix a time in which the operator shall provide and thereafter maintain such safeguard. If the safeguard is not provided within the time fixed and if it is not maintained thereafter, a notice shall be issued to the operator pursuant to section 104 of the Act.
(c) Nothing in the sections in the S 75.1403 series in this subpart O precludes the issuance of a withdrawal order because of imminent danger.
S 75.1403-2 Criteria-Hoists transporting materials; brakes.
Hoists and elevators used to transport materials should be equipped with brakes capable of stopping and holding the fully loaded platform, cage, skip, car, or other device at any point in the shaft, slope, or incline.
S 75.1403-3 Criteria-Drum clutch; cage construction.
(a) The clutch of a free-drum on a personnel hoist should be provided with a locking mechanism or interlocked with the brake to prevent accidental withdrawal of the clutch.
(b) Cages used for hoisting persons should be constructed with the sides enclosed to a height of at least six feet and should have gates, safety chains, or bars across the ends of the cage when persons are being hoisted or lowered.
(c) Self-dumping cages, platforms, or other devices used for transportation of persons should have a locking device to prevent tilting when persons are transported.
(d) An attendant should be on duty at the surface when persons are being hoisted or lowered at the beginning and end of each shift.
(e) Precautions should be taken to protect persons working in shaft sumps.
(f) Workers should wear safety belts while doing work in or over shafts.
S 75.1403-4 Criteria-Automatic elevators.
(a) The doors of automatic elevators should be equipped with interlocking switches so arranged that the elevator car will be immovable while any door is opened or unlocked, and arranged so that such door or doors cannot be inadvertently opened when the elevator car is not at a landing.
(b) A "Stop" switch should be provided in the automatic elevator compartment that will permit the elevator to be stopped at any location in the shaft.
(c) A slack cable device should be used where appropriate on automatic elevators which will automatically shut-off the power and apply the brakes in the event the elevator is obstructed while descending.
(d) Each automatic elevator should be provided with a telephone or other effective communica- tion system by which aid or assistance can be obtained promptly.
S 75.1403-5 Criteria-Belt conveyors.
(a) Positive-acting stop controls should be installed along all belt conveyors used to transport men, and such controls should be readily accessible and maintained so that the belt can be stopped or started at any location.
(b) Belt conveyors used for regularly scheduled mantrips should be stopped while men are loading or unloading.
(c) All belt conveyors used for the transportation of persons should have a minimum vertical clearance of 18 inches from the nearest overhead projection when measured from the edge of the belt and there should be at least 36 inches of side clearance where men board or leave such belt conveyors.
(d) When men are being transported on regularly scheduled mantrips on belt conveyors the belt speed should not exceed 300 feet per minute when the vertical clearance is less than 24 inches, and should not exceed 350 feet per minute when the vertical clearance is 24 inches or more.
(e) Adequate illumination including colored lights or reflective signs should be installed at all loading and unloading stations. Such colored lights and reflective signs should be so located as to be observable to all persons riding the belt conveyor.
(f) After supplies have been transported on belt conveyors such belts should be examined for unsafe conditions prior to the transportation of men on regularly scheduled mantrips, and belt conveyors should be clear before men are transported.
(g) A clear travelway at least 24 inches wide should be provided on both sides of all belt convey- ors installed after March 30, 1970. Where roof supports are installed within 24 inches of a belt conveyor, clear travelway at least 24 inches wide should be provided on the side of such support farthest from the conveyor.
(h) On belt conveyors that do not transport men, stop and start controls should be installed at intervals not to exceed 1,000 feet. Such controls should be properly installed and positioned so as to be readily accessible.
(i) Telephone or other suitable communications should be provided at points where men or supplies are regularly loaded on or unloaded from the belt conveyors.
(j) Persons should not cross moving belt conveyors, except where suitable crossing facilities are provided.
S 75.1403-6 Criteria-Self-propelled personnel carriers.
(a) Each self-propelled personnel carrier should:
(1) Be provided with an audible warning device;
(2) Be provided with a sealed-beam headlight, or its equivalent, on each end;
(3) Be provided with reflectors on both ends and sides.
(b) In addition, each track-mounted self-propelled personnel carrier should:
(1) Be provided with a suitable lifting jack and bar, which shall be secured or carried in a tool compartment;
(2) Be equipped with 2 separate and independent braking systems properly installed and well maintained;
(3) Be equipped with properly installed and well-maintained sanding devices, except that person- nel carriers (jitneys), which transport not more than 5 men, need not be equipped with such sanding device;
(4) If an open type, be equipped with guards of sufficient strength and height to prevent person- nel from being thrown from such carriers.
S 75.1403-7 Criteria-Mantrips.
(a) Mantrips should be operated independently of any loaded trip, empty trip, or supply trip and should not be operated within 300 feet of any trip, including another mantrip.
(b) A sufficient number of mantrip cars should be provided to prevent overcrowding of men.
(c) Mantrips should not be pushed.
(d) Where mantrips are operated by locomotives on slopes such mantrips should be coupled to the front and rear by locomotives capable of holding such mantrips. Where ropes are used on slopes for mantrip haulage, such conveyances should be connected by chains, steel ropes, or other effective devices between mantrip cars and the rope.
(e) Safety goggles or eyeshields should be provided for all persons being transported in open-type mantrips.
(f) All trips, including trailers and sleds, should be operated at speeds consistent with conditions and the equipment used, and should be so controlled that they can be stopped within the limits of visibil- ity.
(g) All mantrips should be under the direction of a supervisor and the operator of each mantrip should be familiar with the haulage safety rules and regulations.
(h) Men should proceed in an orderly manner to and from mantrips and no person should be permitted to get on or off a moving mantrip.
(i) [Reserved]
(j) Mantrips should not be permitted to proceed until the operator of the mantrip is assured that he has a clear road.
(k) Supplies or tools, except small hand tools or instruments, should not be transported with men.
(l) At places where men enter or leave mantrip conveyances, ample clearance should be provided and provisions made to prevent persons from coming in contact with energized electric circuits.
(m) The mine car next to a trolley locomotive should not be used to transport men. Such cars may be used to transport small tools and supplies. This is not to be construed as permitting the transpor- tation of large or bulky supplies such as shuttle car wheel units, or similar material.
(n) Drop-bottom cars used to transport men should have the bottoms secured with an additional locking device.
(o) Extraneous materials or supplies should not be transported on top of equipment; however, materials and supplies that are necessary for or related to the operation of such equipment may be trans- ported on top of such equipment if a hazard is not introduced.
S 75.1403-8 Criteria-Track haulage roads.
(a) The speed at which haulage equipment is operated should be determined by the condition of the roadbed, rails, rail joints, switches, frogs, and other elements of the track and the type and condition of the haulage equipment.
(b) Track haulage roads should have a continuous clearance on one side of at least 24 inches from the farthest projection of normal traffic. Where it is necessary to change the side on which clear- ance is provided, 24 inches of clearance should be provided on both sides for a distance of not less than 100 feet and warning signs should be posted at such locations.
(c) Track haulage roads developed after March 30, 1970, should have clearance on the "tight" side of at least 12 inches from the farthest projection of normal traffic. A minimum clearance of 6 inches should be maintained on the "tight" side of all track haulage roads developed prior to March 30, 1970.
(d) The clearance space on all track haulage roads should be kept free of loose rock, supplies, and other loose materials.
(e) Positive stopblocks or derails should be installed on all tracks near the top and at landings of shafts, slopes, and surface inclines.
S 75.1403-9 Criteria-Shelter holes.
(a) Shelter holes should be provided on track haulage roads at intervals of not more than 105 feet unless otherwise approved by the Coal Mine Safety District Manager(s).
(b) Shelter holes should be readily accessible and should be at least 5 feet in depth, not more than feet in width (except crosscuts used as shelter holes) and at least the height of the coal seam where the coal seam is less than 6 feet high and at least 6 feet in height where the coal seam is 6 feet or more in height.
(c) Shelter holes should be kept free of refuse and other obstructions. Crosscuts used as shelter holes should be kept free of refuse or other materials to a depth of at least 15 feet.
(d) Shelter holes should be provided at all manually operated doors and at switch throws except:
(1) At room switches, or (2) at switches where more than 6 feet of side clearance is provided. The Coal Mine Safety District Manager(s) may permit exemption of this requirement if such shelter holes create a hazardous roof condition. A copy of this permit, if issued, shall be filed with the State Mine Inspector.
(e) At each underground slope landing where men pass and cars are handled, a shelter hole at least 10 feet in depth, 4 feet in width, and 6 feet in height should be provided.
S 75.1403-10 Criteria-Haulage; general.
(a) A permissible trip light or other approved device such as reflectors, approved by the Coal Mine Safety District Manager(s), should be used on the rear of trips pulled, on the front of trips pushed and on trips lowered in slopes. However, trip lights or other approved devices need not be used on cars being shifted to and from loading machines, on cars being handled at loading heads, during gathering operations at working faces, when trailing locomotives are used, or on trips pulled by animals.
(b) Cars on main haulage roads should not be pushed, except where necessary to push cars from side tracks located near the working section to the producing entries and rooms, where necessary to clear switches and sidetracks, and on the approach to cages, slopes, and surface inclines.
(c) Warning lights or reflective signs or tapes should be installed along haulage roads at locations of abrupt or sudden changes in the overhead clearance.
(d) No person, other than the motorman and brakeman, should ride on a locomotive unless authorized by the mine foreman, and then only when safe riding facilities are provided. No person should ride on any loaded car or on the bumper of any car. However, the brakeman may ride on the rear bumper of the last car of a slow moving trip pulled by a locomotive.
(e) Positive-acting stopblocks or derails should be used where necessary to protect persons from danger of runaway haulage equipment.
(f) An audible warning should be given by the operator of all self-propelled equipment including off-track equipment, where persons may be endangered by the movement of the equipment.
(g) Locomotives and personnel carriers should not approach to within 300 feet of preceding haulage equipment, except trailing locomotives that are an integral part of the trip.
(h) A total of at least 36 inches of unobstructed side clearance (both sides combined) should be provided for all rubber-tired haulage equipment where such equipment is used.
(i) Off-track haulage roadways should be maintained as free as practicable from bottom irregu- larities, debris, and wet or muddy conditions that affect the control of the equipment.
(j) Operators of self-propelled equipment should face in the direction of travel.
(k) Mechanical steering and control devices should be maintained so as to provide positive control at all times.
(l) All self-propelled rubber-tired haulage equipment should be equipped with well maintained brakes, lights, and a warning device.
(m) On and after March 30, 1971, all tram control switches on rubber-tired equipment should be designed to provide automatic return to the stop or off position when released.
S 75.1403-11 Criteria-Entrances to shafts and slopes.
All open entrances to shafts should be equipped with safety gates at the top and at each landing. Such gates should be self-closing and should be kept closed except when the cage is at such landing.
S 75.1404 Automatic brakes; speed reduction gear.
[Statutory Provisions]
Each locomotive and haulage car used in an underground coal mine shall be equipped with automatic brakes, where space permits. Where space does not permit automatic brakes, locomotives and haulage cars shall be subject to speed reduction gear, or other similar devices approved by the Secretary, which are designed to stop the locomotives and haulage cars with the proper margin of safety.
S 75.1404-1 Braking system.
A locomotive equipped with a dual braking system will be deemed to satisfy the requirements of 75.1404 for a train comprised of such locomotive and haulage cars, provided the locomotive is oper- ated within the limits of its design capabilities and at speeds consistent with the condition of the haulage road. A trailing locomotive or equivalent devices should be used on trains that are operated on ascending grades.
S 75.1405 Automatic couplers.
[Statutory Provisions]
All haulage equipment acquired by an operator of a coal mine on or after March 30, 1971, shall be equipped with automatic couplers which couple by impact and uncouple without the necessity of persons going between the ends of such equipment. All haulage equipment without automatic couplers in use in a mine on March 30, 1970, shall also be so equipped within 4 years after March 30, 1970.
S 75.1405-1 Automatic couplers, haulage equipment.
The requirement of S 75.1405 with respect to automatic couplers applies only to track haulage cars which are regularly coupled and uncoupled.
Wire Ropes
S 75.1429 Guide ropes.
If guide ropes are used in shafts for personnel hoisting applications other than shaft development, the nominal strength (manufacturer's published catalog strength) of the guide rope at installation shall meet the minimum value calculated as follows: Minimum value = Static Load X 5.0.
S 75.1430 Wire ropes; scope.
(a) Sections 75.1430 through 75.1438 apply to wire ropes in service used to hoist--
(1) Persons in shafts or slopes underground; or
(2) Loads in shaft or slope development when persons work below the suspended loads.
(b) These standards do not apply to wire ropes used for elevators.
S 75.1431 Minimum rope strength.
At installation, the nominal strength (manufacturer's published catalog strength) of wire ropes used for hoisting shall meet the minimum rope strength values obtained by the following formulas in which "L" equals the maximum suspended rope length in feet:
(a) Winding drum ropes (all constructions, including rotation resistant). For rope lengths less than 3,000 feet: Minimum Value = Static Load X (7.0-0.001L) For rope lengths 3,000 feet or greater: Minimum Value = Static Load X 4.0
[48 FR 53239, Nov. 25, 1983; 48 FR 54975, Dec. 8, 1983]
S 75.1432 Initial measurement.
After initial rope stretch but before visible wear occurs, the rope diameter of newly installed wire ropes shall be measured at least once in every third interval of active length and the measurements averaged to establish a baseline for subsequent measurements. A record of the measurements and the date shall be made by the person taking the measurements. This record shall be retained until the rope is retired from service.
S 75.1433 Examinations.
(a) At least once every fourteen calendar days, each wire rope in service shall be visually exam- ined along its entire active length for visible structural damage, corrosion, and improper lubrication or dressing. In addition, visual examination for wear and broken wires shall be made at stress points, including the area near attachments, where the rope rests on sheaves, where the rope leaves the drum, at drum crossovers, and at change-of-layer regions. When any visible condition that results in a reduction of rope strength is present, the affected portion of the rope shall be examined on a daily basis.
(b) Before any person is hoisted with a newly installed wire rope or any wire rope that has not been examined in the previous fourteen calendar days, the wire rope shall be examined in accordance with paragraph (a) of this section.
(c) At least once every six months, nondestructive tests shall be conducted of the active length of the rope, or rope diameter measurements shall be made--
(1) Wherever wear is evident;
(2) Where the hoist rope rests on sheaves at regular stopping points;
(3) Where the hoist rope leaves the drum at regular stopping points; and
(4) At drum crossover and change-of-layer regions.
(d) At the completion of each examination required by paragraph (a) of this section, the person making the examination shall certify, by signature and date, that the examination has been made. If any condition listed in paragraph (a) of this standard is present, the person conducting the examination shall make a record of the condition and the date. Certifications and records of examinations shall be retained for one year.
(e) The person making the measurements or nondestructive tests as required by paragraph (c) of this section shall record the measurements or test results and the date. This record shall be retained until the rope is retired from service.
S 75.1434 Retirement criteria.
Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:
(a) The number of broken wires within a rope lay length, excluding filler wires, exceeds either--
(1) Five percent of the total number of wires; or
(2) Fifteen percent of the total number of wires within any strand;
(b) On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length;
(c) A loss of more than one-third of the original diameter of the outer wires;
(d) Rope deterioration from corrosion;
(e) Distortion of the rope structure;
(f) Heat damage from any source;
(g) Diameter reduction due to wear that exceeds six percent of the baseline diameter measure- ment; or
(h) Loss of more than ten percent of rope strength as determined by nondestructive testing.
S 75.1435 Load end attachments.
(a) Wire rope shall be attached to the load by a method that develops at least 80 percent of the nominal strength of the rope.
(b) Except for terminations where use of other materials is a design feature, zinc (spelter) shall be used for socketing wire ropes. Design feature means either the manufacturer's original design or a design approved by a registered professional engineer.
(c) Load end attachment methods using splices are prohibited.
S 75.1436 Drum end attachment.
(a) For drum end attachment, wire rope shall be attached--
(1) Securely by clips after making one full turn around the drum spoke;
(2) Securely by clips after making one full turn around the shaft, if the drum is fixed to the shaft; or
(3) By properly assembled anchor bolts, clamps, or wedges, provided that the attachment is a design feature of the hoist drum. Design feature means either the manufacturer's original design or a design approved by a registered professional engineer.
(b) A minimum of three full turns of wire rope shall be on the drum when the rope is extended to its maximum working length.
S 75.1437 End attachment retermination.
Damaged or deteriorated wire rope shall be removed by cutoff and the rope reterminated where there is--
(a) More than one broken wire at an attachment;
(b) Improper installation of an attachment;
(c) Slippage at an attachment; or
(d) Evidence of deterioration from corrosion at an attachment.
S 75.1438 End attachment replacement.
Wire rope attachments shall be replaced when cracked, deformed, or excessively worn.
Subpart P--Emergency Shelters
S 75.1500 Emergency shelters.
[Statutory Provisions]
The Secretary or an authorized representative of the Secretary may prescribe in any coal mine that rescue chambers, properly sealed and ventilated, be erected at suitable locations in the mine to which persons may go in case of an emergency for protection against hazards. Such chambers shall be properly equipped with first aid materials, an adequate supply of air and self-contained breathing equip- ment, an independent communication system to the surface, and proper accommodations for the persons while awaiting rescue, and such other equipment as the Secretary may require. A plan for the erection, maintenance, and revisions of such chambers and the training of the miners in their proper use shall be submitted by the operator to the Secretary for his approval. A copy of the approved plan shall be filed with the State Mine Inspector.
Subpart Q--Communications
S 75.1600 Communications.
[Statutory Provisions]
Telephone service or equivalent two-way communication facilities, approved by the Secretary or his authorized representative, shall be provided between the surface and each landing of main shafts and slopes and between the surface and each working section of any coal mine that is more than 100 feet from a portal.
S 75.1600-1 Communication facilities; main portals; installation requirements.
A telephone or equivalent two-way communication facility shall be located on the surface within 500 feet of all main portals, and shall be installed either in a building or in a box-like structure designed to protect the facilities from damage by inclement weather. At least one of these communication facili- ties shall be at a location where a responsible person who is always on duty when men are underground can hear the facility and respond immediately in the event of an emergency.
S 75.1600-2 Communication facilities; working sections; installation and maintenance require- ments; audible or visual alarms.
(a) Telephones or equivalent two-way communication facilities provided at each working section shall be located not more than 500 feet outby the last open crosscut and not more than 800 feet from the farthest point of penetration of the working places on such section.
(b) The incoming communication signal shall activate an audible alarm, distinguishable from the surrounding noise level, or a visual alarm that can be seen by a miner regularly employed on the working section.
(c) If a communication system other than telephones is used and its operation depends entirely upon power from the mine electric system, means shall be provided to permit continued communication in the event the mine electric power fails or is cut off; provided, however, that where trolley phones and telephones are both used, an alternate source of power for the trolley phone system is not required.
(d) Trolley phones connected to the trolley wire shall be grounded in accordance with subpart H of this part.
(e) Telephones or equivalent two-way communication facilities shall be maintained in good operating condition at all times. In the event of any failure in the system that results in loss of communi- cation, repairs shall be started immediately, and the system restored to operating condition as soon as possible.
Subpart R--Miscellaneous
S 75.1700 Oil and gas wells.
[Statutory Provisions]
Each operator of a coal mine shall take reasonable measures to locate oil and gas wells penetrat- ing coalbeds or any underground area of a coal mine. When located, such operator shall establish and maintain barriers around such oil and gas wells in accordance with State laws and regulations, except that such barriers shall not be less than 300 feet in diameter, unless the Secretary or his authorized representative permits a lesser barrier consistent with the applicable State laws and regulations where such lesser barrier will be adequate to protect against hazards from such wells to the miners in such mine, or unless the Secretary or his authorized representative requires a greater barrier where the depth of the mine, other geologic conditions, or other factors warrant such a greater barrier.
S 75.1702 Smoking; prohibition.
[Statutory Provisions]
No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or around oil houses, explosives magazines, or other surface areas where such practice may cause a fire or explosion. The operator shall institute a program, approved by the Secretary, to insure that any person entering the underground area of the mine does not carry smoking materials, matches, or lighters. A copy of this approved plan shall be filed with the State Mine Inspector.
S 75.1702-1 Smoking programs.
Programs required under S 75.1702 shall be submitted to the Coal Mine Safety District Manager for approval on or before May 30, 1970.
S 75.1703 Portable electric lamps.
[Statutory Provisions]
Persons underground shall use only permissible electric lamps approved by the Secretary for portable illumination. No open flame shall be permitted in the underground area of any coal mine, except as permitted under S 75.1106.
S 75.1703-1 Permissible lamps.
Lamps approved by the Bureau of Mines or the Mine Safety and Health Administration under part 19 or part 20 of this chapter (Bureau of Mines Schedule 6D and Schedule 10C) are approved lamps for the purposes of S 75.1703.
S 75.1707-1 New working section.
The term "new working section" as used in S 75.1707 means any extension of the belt or trolley haulage system in main, cross, and room entries necessary for the development of the mine on and after March 30, 1970. Room entries being developed as of March 30, 1970, with certified stop line limitations as shown on the mine map and retreating panels shall not be considered as new working sections.
S 75.1708 Surface structures, fireproofing.
[Statutory Provisions]
After March 30, 1970, all structures erected on the surface within 100 feet of any mine opening shall be of fireproof construction. Unless structures existing on or prior to such date which are located within 100 feet of any mine opening are of such construction, fire doors shall be erected at effective points in mine openings to prevent smoke or fire from outside sources endangering miners underground.
These doors shall be tested at least monthly to insure effective operation. A record of such tests shall be kept in an area on the surface of the mine chosen by the operator to minimize the danger of destruction by fire or other hazard and shall be available for inspection by interested persons.
S 75.1708-1 Surface structures; fireproof construction.
Structures of fireproof construction is interpreted to mean structures with fireproof exterior surfaces.
S 75.1709 Accumulations of methane and coal dust on surface coal-handling facilities.
[Statutory Provisions]
Adequate measures shall be taken to prevent methane and coal dust from accumulating in exces- sive concentrations in or on surface coal-handling facilities, but in no event shall methane be permitted to accumulate in concentrations in or on surface coal-handling facilities in excess of limits established for methane by the Secretary on and after March 30, 1971. Where coal is dumped at or near air-intake openings, provisions shall be made to avoid dust from entering the mine.
S 75.1710 Canopies or cabs; diesel-powered and electric face equipment.
[Statutory Provisions]
In any coal mine where the height of the coalbed permits, An authorized representative of the Secretary may require that diesel-powered equipment and electric face equipment, including shuttle cars, be provided with substantially constructed canopies, or cabs, to protect the miners operating such equipment from roof falls and from rib and face rolls.
S 75.1710-1 Canopies or cabs; self-propelled diesel-powered and electric face equipment; installa- tion requirements.
(a) Except as provided in paragraph (f) of this section, all self-propelled diesel-powered and electric face equipment, including shuttle cars, which is employed in the active workings of each under- ground coal mine on and after January 1, 1973, shall, in accordance with the schedule of time specified in paragraphs (a)(1), (2), (3), (4), (5), and (6) of this section, be equipped with substantially constructed canopies or cabs, located and installed in such a manner that when the operator is at the operating con- trols of such equipment he shall be protected from falls of roof, face, or rib, or from rib and face rolls.
The requirements of this paragraph (a) shall be met as follows:
(1) On and after January 1, 1974, in coal mines having mining heights of 72 inches or more;
(2) On and after July 1, 1974, in coal mines having mining heights of 60 inches or more, but less than 72 inches;
(3) On and after January 1, 1975, in coal mines having mining heights of 48 inches or more, but less than 60 inches;
(4) On and after July 1, 1975, in coal mines having mining heights of 36 inches or more, but less than 48 inches;
(5) (i) On and after January 1, 1976, in coal mines having mining heights of 30 inches or more, but less than 36 inches,
(ii) On and after July 1, 1977, in coal mines having mining heights of 24 inches or more, but less than 30 inches, and
(6) On and after July 1, 1978, in coal mines having mining heights of less than 24 inches.
(b)(1) For purposes of this section, a canopy means a structure which provides overhead protec- tion against falls of roof.
(2) For purposes of this section, a cab means a structure which provides overhead and lateral protection against falls of roof, rib, and face, or rib and face rolls.
(c) In determining whether to install substantially constructed canopies as opposed to substan- tially constructed cabs, the operator shall consider and take into account the following factors:
(1) The mining method used;
(2) Physical limitations, including but not limited to the dip of the coalbed, and roof, rib, and face conditions;
(3) Previous accident experience, if any, caused by falls of roof, rib, and face, or rib and face rolls;
(4) Overhead protection, such as that afforded by a substantially constructed canopy, against falls of roof will always be required; and
(5) Lateral protection, such as that afforded by a substantially constructed cab, may also be necessary where the occurrence of falls of rib and face, or rib and face rolls is likely.
(d) For purposes of this section, a canopy or cab will be considered to be substantially con- structed if a registered engineer certifies that such canopy or cab has the minimum structural capacity to support elastically: (1) A dead weight load of 18,000 pounds, or (2) 15 p.s.i. distributed uniformly over the plan view area of the structure, whichever is lesser.
(e) Evidence of the certification required by paragraph (d) of this section shall be furnished by attaching a plate, label, or other appropriate marking to the canopy or cab for which certification has been made, stating that such canopy or cab meets the minimum requirements for structural capacity set forth in paragraph (d) of this section. Written evidence of such certification shall also be retained by the operator, and shall be made available to an authorized representative of the Secretary and the State Mine Inspector upon request. Written evidence of certification may consist of the report of the registered engineer who certified the canopy or cab, or of information from the manufacturer of the canopy or cab stating that a registered engineer has certified that the canopy or cab meets the minimum requirements for structural capacity set forth in paragraph (d) of this section.
(f) An operator may apply to the Director of Technical Support, Mine Safety and Health Administra- tion, Department of Labor, 4015 Wilson Boulevard, Arlington, Va. 22203, for approval of the installa- tion of devices to be used in lieu of substantially constructed canopies or cabs on self-propelled diesel- powered and electric face equipment. The Director of Technical Support may approve such devices if he determines that the use thereof will afford the equipment operator no less than the same measure of protection from falls of roof, face, or rib, or from rib and face rolls as would a substantially constructed canopy or cab meeting the requirements of this section.
S 75.1711 Sealing of mines.
[Statutory Provisions]
On or after March 30, 1970, the opening of any coal mine that is declared inactive by the opera- tor, or is permanently closed, or abandoned for more than 90 days, shall be sealed by the operator in a manner prescribed by the Secretary and the State Mine Inspector. Openings of all other mines shall be adequately protected in a manner prescribed by the Secretary and the State Mine Inspector to prevent entrance by unauthorized persons.
S 75.1711-1 Sealing of shaft openings.
Shaft openings required to be sealed under S 75.1711 shall be effectively capped or filled. Filling shall be for the entire depth of the shaft and, for the first 50 feet from the bottom of the coalbed, the fill shall consist of incombustible material. Caps consisting of a 6-inch thick concrete cap or other equiva- lent means may be used for sealing. Caps shall be equipped with a vent pipe at least 2 inches in diameter extending for a distance of at least 15 feet above the surface of the shaft.
S 75.1711-2 Sealing of slope or drift openings.
Slope or drift openings required to be sealed under S 75.1711 shall be sealed with solid, substan- tial, incombustible material, such as concrete blocks, bricks or tile, or shall be completely filled with incombustible material for a distance of at least 25 feet into such openings.
S 75.1711-3 Openings of active mines.
The openings of all mines not declared by the operator, to be inactive, permanently closed, or abandoned for less than 90 days shall be adequately fenced or posted with conspicuous signs prohibiting the entrance of unauthorized persons.
S 75.1712 Bath houses and toilet facilities.
[Statutory Provisions]
The Secretary may require any operator to provide adequate facilities for the miners to change from the clothes worn underground, to provide for the storing of such clothes from shift to shift, and to provide sanitary and bathing facilities. Sanitary toilet facilities shall be provided in the active workings of the mine when such surface facilities are not readily accessible to the active workings.
S 75.1712-1 Availability of surface bathing facilities; change rooms; and sanitary facilities.
Except where a waiver has been granted pursuant to the provisions of S 75.1712-4, each operator of an underground coal mine shall on and after December 30, 1970, provide bathing facilities, clothing change rooms, and sanitary facilities, as hereinafter prescribed, for the use of the miners at the mine.
S 75.1712-2 Location of surface facilities.
Bathhouses, change rooms, and sanitary toilet facilities shall be in a location convenient for the use of the miners. Where such facilities are designed to serve more than one mine, they shall be centrally located so as to be as convenient for the use of the miners in all the mines served by such facilities.
S 75.1712-3 Minimum requirements of surface bathing facilities, change rooms, and sanitary toilet facilities.
(a) All bathing facilities, change rooms, and sanitary toilet facilities shall be provided with adequate light, heat, and ventilation so as to maintain a comfortable air temperature and to minimize the accumulation of moisture and odors, and such facilities shall be maintained in a clean and sanitary condition.
(b) Bathing facilities, change rooms, and sanitary toilet facilities shall be constructed and equipped so as to comply with applicable State and local building codes: Provided, however, That where no State or local building codes apply to such facilities, or where no State or local building codes exist, such facilities shall be constructed and equipped so as to meet the minimum construction requirements of the National Building Code; and the minimum plumbing requirements of the U.S.A. Standard Plumb- ing Code, ASA A40.8-1955.
(c) In addition to the minimum requirements specified in paragraphs (a) and (b) of this S 75.1712-3, facilities maintained in accordance with S 75.1712-1 shall include the following:
(1) Bathing facilities. (i) Showers shall be provided with both hot and cold water.
(ii) At least one shower head shall be provided where five or less miners use such showers.
(iii) Where five or more miners use such showers, sufficient showers shall be furnished to pro- vide approximately one shower head for each five miners.
(iv) A suitable cleansing agent shall be provided for use at each shower.
(2) Sanitary toilet facilities. (i) At least one sanitary flush toilet shall be provided where 10 or less miners use such facilities.
(ii) Where 10 or more miners use such sanitary toilet facilities, sufficient toilets shall be fur- nished to provide approximately one sanitary flush toilet for each 10 miners.
(iii) Where 30 or more miners use sanitary toilet facilities, one urinal may be substituted for one sanitary flush toilet; however, where such substitutions are made they shall not reduce the number of toilets below a ratio of two toilets to one urinal.
(iv) An adequate supply of toilet paper shall be provided with each toilet.
(v) Adequate handwashing facilities or hand lavatories shall be provided in or adjacent to each toilet facility.
(3) Change rooms. (i) Individual clothes storage containers or lockers shall be provided for storage of miners clothing and other incidental personal belongings during and between shifts.
(ii) Change rooms shall be provided with ample space to permit the use of such facilities by all miners changing clothes prior to and after each shift.
S 75.1712-4 Waiver of surface facilities requirements.
The Coal Mine Safety District Manager for the district in which the mine is located may, upon written application by the operator, waive any or all of the requirements of SS 75.1712-1 through 75.1712-3 if he determines that the operator of the mine cannot or need not meet any part or all of such requirements, and, upon issuance of such waiver, he shall set forth the facilities which will not be re- quired and the specific reason or reasons for such waiver. A copy of this waiver shall be filed with the State Mine Inspector.
S 75.1712-5 Application for waiver of surface facilities.
Applications for waivers of the requirements of SS 75.1712-1 through 75.1712-3 shall be filed with the Coal Mine Safety District Manager and shall contain the following information:
(a) The name and address of the mine operator;
(b) The name and location of the mine;
(c) A statement explaining why, in the opinion of the operator, the installation or maintenance of the facilities is impractical or unnecessary.
S 75.1712-6 Underground sanitary facilities; approved sanitary toilets; installation and maintenance.
(a) Except as provided in S 75.1712-7, each operator of an underground coal mine shall, on and after December 30, 1970, provide and maintain one approved sanitary toilet, together with an adequate supply of toilet tissue, in a dry location under protected roof, within 500 feet of each working place in the mine where miners are regularly employed during the mining cycle. A single approved sanitary toilet may serve two or more working places in the same mine, if it is located within 500 feet of each such working place.
(b) Only sanitary toilets approved by the Health Division, Coal Mine Health and Safety, Mine Safety and Health Administration shall meet the requirements of this section.
(c) Applications for approval of sanitary toilets shall be submitted to: Health Division, Coal Mine Health and Safety, Mine Safety and Health Administration, Department of Labor, 4015 Wilson Boule- vard, Arlington, Va. 22203.
S 75.1712-7 Underground sanitary facilities; waiver of requirements.
If it has been determined by the Coal Mine Safety District Manager for the district in which the mine is located that sanitary toilets cannot be provided and maintained within 500 feet of a working place because of the thickness of the coal seam or because of any other physical restriction in the under- ground workings, he may, upon written application by the operator, waive the location requirements for underground sanitary facilities with respect to such working place. A copy of this waiver shall be filed with the State Mine Inspector.
S 75.1712-8 Application for waiver of location requirements for underground sanitary facilities.
Applications for waivers of the location requirements of S 75.1712-6 shall be filed with the Coal Mine Safety District Manager and shall contain the following information:
(a) The name and address of the mine operator;
(b) The name and location of the mine;
(c) The thickness of the coal seam in each working place in the mine for which a waiver is requested; and
(d) Other physical restrictions in the mine (for example, poor roof conditions, excessive water, timbering, etc.). If a sanitary toilet cannot be installed within 500 feet of a working place because of physical conditions other than the thickness of the coal seam, the operator shall also include a short statement specifying areas in the mine which could be considered possible alternative sites for installa- tion of such facilities.
S 75.1712-9 Issuance of waivers.
Following the receipt of an application submitted in accordance with the provisions of S 75.1712-8, the Coal Mine Safety District Manager shall, if he determines that the operator cannot meet the location requirements of S 75.1712-6 with respect to any or all of the working places in the mine because of the coal seam thickness or because of other physical restriction, issue a waiver of the require- ments of this section and designate an alternative site for installation of such facilities. The waiver issued shall specify each working place to which it shall apply, set forth the reasons for such waiver, and the reasons for designation of the alternative site.
S 75.1712-10 Underground sanitary facilities; maintenance.
Sanitary toilets shall be regularly maintained in a clean and sanitary condition. Holding tanks shall be serviced and cleaned when full and in no case less than once each week by draining or pumping or by removing them to the surface for cleaning or recharging. Transfer tanks and transfer equipment used underground shall be equipped with suitable fittings to permit complete drainage of holding tanks without spillage and allow for the sanitary transportation of wastes to the surface. Waste shall be dis- posed of on the surface in accordance with State and local laws and regulations.
S 75.1713 Emergency medical assistance; first-aid.
[Statutory Provisions]
Each operator shall make arrangements in advance for obtaining emergency medical assistance and transportation for injured persons. Emergency communications shall be provided to the nearest point of assistance. Selected agents of the operator shall be trained in first-aid and first-aid training shall be made available to all miners. Each coal mine shall have an adequate supply of first-aid equipment located on the surface, at the bottom of shafts and slopes, and at other strategic locations near the work- ing faces. In fulfilling each of the requirements of this section, the operator shall meet at least minimum requirements prescribed by the Secretary of Health and Human Services.
S 75.1713-1 Arrangements for emergency medical assistance and transportation for injured per- sons; agreements; reporting requirements; posting requirements.
S 75.1713-2 Emergency communications; requirements.
S 75.1713-3 First-Aid training; supervisory employees.
The mine operator shall conduct first-aid training courses for selected supervisory employees at the mine. Within 60 days after the selection of a new supervisory employee to be so trained, the mine operator shall certify by signature and date the name of the employee and date on which the employee satisfactorily completed the first-aid training course. The certification shall be kept at the mine and made available on request to an authorized representative of the Secretary and the State Mine Inspector.
S 75.1713-4 First-aid training program; availability of instruction to all miners.
On or before June 30, 1971, each operator of an underground coal mine shall make available to all miners employed in the mine a course of instruction in first-aid conducted by the operator or under the auspices of the operator, and such a course of instruction shall be made available to newly employed miners within 6 months after the date of employment.
S 75.1713-5 First-aid training program; retraining of supervisory employees; availability to all miners.
Beginning January 1, 1971, each operator of an underground coal mine shall conduct refresher first-aid training courses each calendar year for all selected supervisory employees, and make available refresher first-aid training courses to all miners employed in the mine.
S 75.1713-6 First-aid training program; minimum requirements.
S 75.1713-7 First-aid equipment; location; minimum requirements.
S 75.1714 Availability of approved self-rescue devices; instruction in use and location.
S 75.1714-1 Approved self-rescue devices.
S 75.1714-3 Self-rescue devices; inspection, testing, maintenance, repair, and recordkeeping.
S 75.1715 Identification check system.
[Statutory Provisions]
Each operator of a coal mine shall establish a check-in and check-out system which will provide positive identification of every person underground, and will provide an accurate record of the persons in the mine kept on the surface in a place chosen to minimize the danger of destruction by fire or other hazard. Such record shall bear a number identical to an identification check that is securely fastened to the lamp belt worn by the person underground. The identification check shall be made of a rust resistant metal of not less than 16 gauge.
S 75.1716 Operations under water.
[Statutory Provisions]
Whenever an operator mines coal from a coal mine opened after March 30, 1970, or from any new working section of a mine opened prior to such date, in a manner that requires the construction, operation, and maintenance of tunnels under any river, stream, lake, or other body of water, that is, in the judgment of the Secretary, sufficiently large to constitute a hazard to miners, such operator shall obtain a permit from the Secretary which shall include such terms and conditions as he deems appropriate to protect the safety of miners working or passing through such tunnels from caveins and other hazards.
Such permits shall require, in accordance with a plan to be approved by the Secretary, that a safety zone be established beneath and adjacent to such body of water. No plan shall be approved unless there is a minimum of cover to be determined by the Secretary, based on test holes drilled by the operator in a manner to be prescribed by the Secretary. A copy of this plan and any changes shall be filed with the State Mine Inspector. No such permit shall be required in the case of any new working section of a mine which is located under any water resource reservoir being constructed by a Federal agency on December 30, 1969, the operator of which is required by such agency to operate in a manner that protects the safety of miners working in such section from cave-ins and other hazards.
S 75.1716-1 Operations under water; notification by operator.
An operator planning to mine coal from coal mines opened after March 30, 1970, or from work- ing sections in mines opened prior to such date, and in such manner that mining operations will be conducted, or tunnels constructed, under any river, stream, lake, or other body of water, shall give notice to the Coal Mine Safety District Manager in the district in which the mine is located and the State Mine Inspector prior to the commencement of such mining operations.
S 75.1716-2 Permit required.
If in the judgment of the Coal Mine Safety District Manager the proposed mining operations referred to in S 75.1716-1 constitute a hazard to miners, he shall promptly so notify the operator that a permit is required.
S 75.1716-3 Applications for permits.
S 75.1716-4 Issuance of permits.
If the Coal Mine Safety District Manager determines that the proposed mining operations under water can be safely conducted, he shall issue a permit for the conduct of such operations under such conditions as he deems necessary to protect the safety of miners engaged in those operations. A copy of this permit and any changes shall be filed with the State Mine Inspector.
S 75.1717 Exemptions.
[Statutory Provisions]
No notice under S 75.1716-1 and no permit under S 75.1716-2 shall be required in the case of any new working section of a mine which is located under any water resource reservoir being con- structed by a Federal agency as of December 30, 1969, and where the operator is required by such agency to operate in a manner that adequately protects the safety of miners.
S 75.1718 Drinking water.
[Statutory Provisions]
An adequate supply of potable water shall be provided for drinking purposes in the active work- ings of the mine, and such water shall be carried, stored, and otherwise protected in sanitary containers.
S 75.1718-1 Drinking water; quality.
(a) Potable water provided in accordance with the provisions of S 75.1718 shall meet the appli- cable minimum health requirements for drinking water established by the State or community in which the mine is located.
(b) Where no state or local health requirements apply to drinking water or where no state or local minimum health requirements exist, drinking water provided in accordance with the provisions of S 75.1718 shall contain a minimum of 0.2 milligrams of free chlorine per liter of water.
S 75.1719 Illumination; purpose and scope of SS 75.1719 through 75.1719-4; time for compliance.
S 75.1719-1 Illumination in working places.
S 75.1719-2 Lighting fixtures; requirements.
(a) Lighting fixtures shall be permissible.
(b) Lighting fixtures may be installed on self-propelled machines or may be stationary lighting fixtures.
(c)(1) Electrically operated lighting fixtures shall be energized by direct current, or by sinusoidal full wave alternating current not less than 50 cycles per second (100 pulses per second), or by an equiva- lent power source that causes no greater flicker.
(2) Alternating current circuits supplying power to stationary lighting fixtures shall contain conductors energized at voltages not greater than 70 volts to ground. Alternating current circuits, ener- gized at 100 volts or more and used to supply power to stationary lighting fixtures, shall originate at a transformer having a center or neutral tap grounded to earth through a proper resistor, which shall be designed to limit fault current to not more than 5 amperes. A grounding circuit in accordance with S 75.701-4 shall originate at the grounded terminal of the grounding resistor and extend along with the power conductors and serve as a grounding conductor for the frames of all equipment receiving power from the circuit. The ground fault current rating of grounding resistors shall meet the "extended time rating" set forth in the Institute of Electrical and Electronics Engineers, Inc. Standard No. 32 (IEEE Std.32-1972) which is hereby incorporated by reference and made a part hereof. The incorporated publica- tion is available for examination at each Coal Mine Health and Safety District and Subdistrict Office of MSHA, and may be obtained from the Institute of Electrical and Electronics Engineers, Inc., 345 East 47th Street, New York, N.Y. 10017.
(3) Machine-mounted lighting fixtures shall be electrically grounded to the machine by a separate grounding conductor in compliance with S 75.701-4.
(d) Direct current circuits in excess of a nominal voltage of 300 volts shall not be used to supply power to stationary light fixtures.
(e) Cables conducting power to stationary lighting fixtures from both alternating and direct current power sources, other than intrinsically safe devices, shall be considered trailing cables, and shall meet the requirements of subpart G of this part. In addition, such cables shall be protected against over- loads and short circuits by a suitable circuit breaker or other device approved by the Secretary. Circuit breakers or other device approved by the Secretary protecting trailing cables receiving power from resistance grounded circuits shall be equipped with a ground trip arrangement which shall be designed to deenergize the circuit at not more than 50% of the available fault current.
(f) Before shunts are removed from blasting caps, lighting fixtures and associated cables located in the same working place shall be deenergized. Furthermore, lighting fixtures shall be removed out of the line of blast and not less than 50 feet from the blasting operation unless otherwise protected against flying debris.
(g) Lighting fixtures shall be designed and installed to minimize discomfort glare.
S 75.1719-3 Methods of measurement; light measuring instruments.
S 75.1720 Protective clothing; requirements.
On and after the effective date of this S 75.1720 each miner regularly employed in the active workings of an underground coal mine shall be required to wear the following protective clothing and devices:
(a) Protective clothing or equipment and face-shields or goggles when welding, cutting, or working with molten metal or when other hazards to the eyes exist from flying particles.
(b) Suitable protective clothing to cover those parts of the body exposed to injury when handling corrosive or toxic substances or other materials which might cause injury to the skin.
(c) Protective gloves when handling materials or performing work which might cause injury to the hands; however, gloves shall not be worn where they would create a greater hazard by becoming entangled in the moving parts of equipment.
(d) A suitable hard hat or hard cap. If a hard hat or hard cap is painted, nonmetallic based paint shall be used.
(e) Suitable protective footwear.
S 75.1720-1 Distinctively colored hard hats, or hard caps; identification for newly employed, inexperienced miners.
Hard hats or hard caps distinctively different in color from those worn by experienced miners shall be worn by each newly employed, inexperienced miner for at least one year from the date of his initial employment as a miner or until he has been qualified or certified as a miner by the State in which he is employed.
S 75.1721 Opening of new underground coal mines, or reopening and reactivating of abandoned or deactivated coal mines, notification by the operator; requirements.
(a) Each operator of a new underground coal mine, and a mine which has been abandoned or deactivated and is to be reopened or reactivated, shall prior to opening, reopening or reactivating the mine notify the Coal Mine Health and Safety District Manager for the district in which the mine is located of the approximate date of the proposed or actual opening of such mine. Thereafter, and as soon as practicable, the operator of such mine shall submit all preliminary plans in accordance with para- graphs (b) and (c) of this section to the District Manager and the operator shall not develop any part of the coalbed in such mine unless and until all preliminary plans have been approved.
(b) The preliminary plans required to be submitted by the operator to the District Manager shall be in writing and shall contain the following:
(1) The name and location of the proposed mine and the Mine Safety and Health Administration mine identification number, if known;
(2) The name and address of the mine operator(s);
(3) The name and address of the principal official designated by the operator as the person who is in charge of health and safety at the mine;
(4) The identification and approximate height of the coalbed to be developed;
(5) The system of mining to be employed;
(6) A proposed roof control plan containing the information specified in S 75.220;
(7) A proposed mine ventilation plan containing the information specified in SS 75.371 and 75.372;
(8) A proposed plan for sealing abandoned areas containing the information specified in SS 75.371 and 75.372;
(9) A proposed program for searching miners for smoking materials in accordance with the provisions of S 75.1702; and,
(10) A proposed plan for emergency medical assistance and emergency communication in accor- dance with the provisions of SS 75.1713-1 and 75.1713-2.
(c) The preliminary plans required to be submitted by the operator to the District Manager shall be in writing and shall contain the following:
(1) The proposed training plan containing the information specified in SS 48.3 and 48.23 of this chapter, and
(2) A proposed plan for training and retraining certified and qualified persons containing the information specified in S 75.160-1.
S 75.1722 Mechanical equipment guards.
(a) Gears; sprockets; chains; drive, head, tail, and takeup pulleys; flywheels; couplings, shafts; sawblades; fan inlets; and similar exposed moving machine parts which may be contacted by persons, and which may cause injury to persons shall be guarded.
(b) Guards at conveyor-drive, conveyor-head, and conveyor-tail pulleys shall extend a distance sufficient to prevent a person from reaching behind the guard and becoming caught between the belt and the pulley.
(c) Except when testing the machinery, guards shall be securely in place while machinery is being operated.
S 75.1723 Stationary grinding machines; protective devices.
(a) Stationary grinding machines other than special bit grinders shall be equipped with:
(1) Peripheral hoods (less than 90o throat openings) capable of withstanding the force of a bursting wheel.
(2) Adjustable tool rests set as close as practical to the wheel.
(3) Safety washers.
(b) Grinding wheels shall be operated within the specifications of the manufacturer of the wheel.
(c) Face shields or goggles, in good condition, shall be worn when operating a grinding wheel.
S 75.1724 Hand-held power tools; safety devices.
Hand-held power tools shall be equipped with controls requiring constant hand or finger pressure to operate the tools or shall be equipped with friction or other equivalent safety devices.
S 75.1725 Machinery and equipment; operation and maintenance.
(a) Mobile and stationary machinery and equipment shall be maintained in safe operating condi- tion and machinery or equipment in unsafe condition shall be removed from service immediately.
(b) Machinery and equipment shall be operated only by persons authorized to operate such machinery or equipment.
(c) Repairs or maintenance shall not be performed on machinery until the power is off and the machinery is blocked against motion, except where machinery motion is necessary to make adjustments.
(d) Machinery shall not be lubricated manually while in motion, unless equipped with extended fittings or cups.
S 75.1726 Performing work from a raised position; safeguards.
(a) Men shall not work on or from a piece of mobile equipment in a raised position until it has been blocked in place securely. This does not preclude the use of equipment specifically designed as elevated mobile work platforms.
(b) No work shall be performed under machinery or equipment that has been raised until such machinery or equipment has been securely blocked in position.
S 75.1727 Drive belts.
(a) Drive belts shall not be shifted while in motion unless the machines are provided with me- chanical shifters.
(b) Belt dressing shall not be applied while belts are in motion except where it can be applied without endangering a person.
S 75.1728 Power-driven pulleys.
(a) Belts, chains, and ropes shall not be guided onto power-driven moving pulleys, sprockets, or drums with the hands except on slow-moving equipment especially designed for hand feeding.
(b) Pulleys of conveyors shall not be cleaned manually while the conveyor is in motion.
(c) Coal spilled beneath belt conveyor drives or tail pieces shall not be removed while the con- veyor is in motion, except where such coal can be removed without endangering persons.
S 75.1729 Welding operations.
Welding operations shall be shielded and the area shall be well ventilated.
S 75.1730 Compressed air; general; compressed air systems.
(a) All pressure vessels shall be constructed, installed, and maintained in accordance with the standards and specifications of Section VIII "Unfired Pressure Vessels," of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code (1971), which is hereby incorporated by refer- ence and made a part hereof. This document may be purchased for $25 from the American Society of Mechanical Engineers, 345 East 47th Street, New York, NY 10017; and it is available for examination in every Coal Mine Health and Safety District and Subdistrict Office.
(b) Compressors and compressed-air receivers shall be equipped with automatic pressure-relief valves, pressure gages, and drain valves.
(c) Repairs involving the pressure system of compressors, receivers, or compressed-air-powered equipment shall not be attempted until the pressure has been relieved from that part of the system to be repaired.
(d) At no time shall compressed air be directed toward a person. When compressed air is used, all necessary precautions shall be taken to protect persons from injury.
(e) Safety chains, suitable locking devices, or automatic cut-off valves shall be used at connec- tions to machines of high-pressure hose lines of three-fourths of an inch inside diameter or larger, and between high-pressure hose lines of three-fourths of an inch inside diameter or larger, where a connec- tion failure would create a hazard. For purposes of this paragraph, high-pressure means pressure of 100 p.s.i. or more.
Subpart S--Approved Books and Records
S 75.1800 Scope.
(a) The provisions of this subpart S set forth the requirements for recording the results of certain tests and examinations conducted in underground coal mines. In addition, it specifies the approved books in which such results are to be recorded and the manner in which they shall be maintained.
(b) The approved books required to be maintained in accordance with the provisions of SS 75.1801 through 75.1808 shall be secured by each operator from commercial sources. Facsimile copies of Mine Safety and Health Administration Forms 6-1331, 6-1489, 6-1490, 6-1491, 6-1492, 6-1493, and 6-1494, have been filed with the Office of the Federal Register, General Services Administration, Wash- ington, D.C. 20408, and sample copies of each of these forms are available for the use of commercial printers or operators at each District or Subdistrict Coal Mine Health and Safety Office of the Mine Safety and Health Administration.
(c) When the District Manager has determined that record books kept in satisfaction of State requirements provide the information specified in any record book required by this subpart S, and so advises the operators of mines located in that State, such approved State record books will be accepted in lieu of the record books specified in this subpart S.
S 75.1806 Monthly examination of surface high voltage circuit breakers; recording requirements; approved books.
The results of monthly examinations of high voltage circuit breakers on the surface required to be conducted under the provisions of SS 75.800, 75.800-3, and 75.800-4, shall be recorded in a book entitled "Monthly Examination of Surface High Voltage Circuit Breakers" (Mine Safety and Health Administration Form 6-1493, Budget Bureau No. 42-R1589, March 1970).
S 75.1808 Maintenance of approved books and records; requirements.
All approved books and records maintained under the provisions of SS 75.1801 through 75.1807 shall be stored in a fireproof repository on the surface of the mine chosen by the mine operator to mini- mize their destruction by fire or other hazard and such records shall be made available to interested persons.
Subpart T-Diesel-Powered Equipment
75.1900 Definitions.
The following definitions apply in this subpart.
Diesel fuel tank. A closed metal vessel specifically designed for the storage or transport of diesel fuel.
Diesel fuel transportation unit. A self-propelled or portable wheeled vehicle used to transport a diesel fuel tank.
Noncombustible material. A material that will continue to serve its intended function for 1 hour when subjected to a fire test incorporating an ASTM E119-88 time/temperature heat input, or equivalent. The publication ASTM E119-88-Standard Test Methods for Fire Tests of Building Construction and Materials-is incorporated by reference and may be inspected at any Coal Mine Health and Safety District and Subdistrict Office; at MSHA's Office of Standards, Regulations, and Variances, 4105 Wilson Boule- vard, Arlington, VA 22203; or at the Office of the Federal Register, 800 North Capitol Street, NW., Washington, DC. This incorporation by reference was approved by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. In addition, copies of the document may be purchased from the American Society for Testing Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103.
Permanent underground diesel fuel storage facility. A facility designed and constructed to remain at one location for the storage or dispensing of diesel fuel, which does not move as mining progresses. Safety can. A metal container intended for storage, transport or dispensing of diesel fuel, with a nominal capacity of 5 gallons, listed or approved by a nationally recognized independent testing labora- tory.
Temporary underground diesel fuel storage area. An area of the mine provided for the short-term storage of diesel fuel in a fuel transportation unit, which moves as mining progresses.
75.1901 Diesel fuel requirements.
(a) Diesel-powered equipment shall be used underground only with a diesel fuel having a sulfur content no greater than 0.05 percent and a flash point of 100 deg. F (38 deg. C) or greater. Upon request, the mine operator shall provide to an authorized representative of the Secretary evidence that the diesel fuel purchased for use in diesel-powered equipment underground meets these requirements.
(b) Flammable liquids shall not be added to diesel fuel used in diesel-powered equipment under- ground.
(c) Only diesel fuel additives that have been registered by the Environmental Protection Agency may be used in diesel-powered equipment underground.
75.1902 Underground diesel fuel storage-general requirements.
75.1903 Underground diesel fuel storage facilities and areas; construction and safety precautions.
75.1904 Underground diesel fuel tanks and safety cans.
75.1905 Dispensing of diesel fuel.
75.1905-1 Diesel fuel piping systems.
75.1906 Transport of diesel fuel.
75.1908 Nonpermissible diesel-powered equipment-categories.
75.1909 Nonpermissible diesel-powered equipment; design and performance requirements.
75.1910 Nonpermissible diesel-powered equipment; electrical system design and perfor- mance requirements.
75.1911 Fire suppression systems for diesel-powered equipment and fuel transportation units.
75.1912 Fire suppression systems for permanent underground diesel fuel storage facilities.
75.1913 Starting aids.
75.1914 Maintenance of diesel-powered equipment.
75.1915 Training and qualification of persons working on diesel-powered equipment.
75.1916 Operation of diesel-powered equipment.
(a) Diesel-powered equipment shall be operated at a speed that is consistent with the type of equipment being operated, roadway conditions, grades, clearances, visibility, and other traffic.
(b) Operators of mobile diesel-powered equipment shall maintain full control of the equipment while it is in motion.
(c) Standardized traffic rules, including speed limits, signals and warning signs, shall be estab- lished at each mine and followed.
(d) Except as required in normal mining operations, mobile diesel-powered equipment shall not be idled.
(e) Diesel-powered equipment shall not be operated unattended.